Weight: 595 pounds 269 kg.
Information:
Note: Inspect the water pump and the water temperature regulator after the cooling system has been drained. This is a good opportunity to replace the water pump, the water temperature regulator and the hoses, if necessary. Drain
Pressurized System: Hot coolant can cause serious burns. To open the cooling system filler cap, stop the engine and wait until the cooling system components are cool. Loosen the cooling system pressure cap slowly in order to relieve the pressure.
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap.
Open the cooling system drain valve (if equipped). If the cooling system is not equipped with a drain valve, remove one of the drain plugs. Note: If equipped, be sure to drain the heater and any related supply and return lines.Allow the coolant to drain.
Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant.
For information regarding the disposal and the recycling of used coolant, consult your Caterpillar dealer or consult Caterpillar Dealer Service Tool Group:Outside Illinois 1-800-542-TOOL
Inside Illinois 1-800-541-TOOL
Canada 1-800-523-TOOL
Flush
Flush the cooling system with clean water in order to remove any debris.
Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to the Specifications Manual, SENR3130, "Torque Specifications" for more information on the proper torques.
Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks.
Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add 0.5 L (1 pint) of cleaner per 15 L (4 US gal) of the cooling system capacity. Install the cooling system filler cap.
Start and run the engine at low idle for a minimum of 30 minutes. The coolant temperature should be at least 82 °C (180 °F).
Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components.To avoid damage to the cooling system, make sure to completely flush the cooling system with clear water. Continue to flush the system until all signs of the cleaning agent are gone.
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. Open the drain valve (if equipped) or remove the cooling system drain plugs. Allow the water to drain. Flush the cooling system with clean water. If equipped, be sure to flush the heater and any related supply and return lines. Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to the Specifications Manual, SENR3130, "Torque Specifications" for more information on the proper torques. Cooling Systems with Heavy Deposits or Plugging
Note: For the following procedure to be effective, there must be some active flow through the
Pressurized System: Hot coolant can cause serious burns. To open the cooling system filler cap, stop the engine and wait until the cooling system components are cool. Loosen the cooling system pressure cap slowly in order to relieve the pressure.
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap.
Open the cooling system drain valve (if equipped). If the cooling system is not equipped with a drain valve, remove one of the drain plugs. Note: If equipped, be sure to drain the heater and any related supply and return lines.Allow the coolant to drain.
Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant.
For information regarding the disposal and the recycling of used coolant, consult your Caterpillar dealer or consult Caterpillar Dealer Service Tool Group:Outside Illinois 1-800-542-TOOL
Inside Illinois 1-800-541-TOOL
Canada 1-800-523-TOOL
Flush
Flush the cooling system with clean water in order to remove any debris.
Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to the Specifications Manual, SENR3130, "Torque Specifications" for more information on the proper torques.
Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks.
Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add 0.5 L (1 pint) of cleaner per 15 L (4 US gal) of the cooling system capacity. Install the cooling system filler cap.
Start and run the engine at low idle for a minimum of 30 minutes. The coolant temperature should be at least 82 °C (180 °F).
Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components.To avoid damage to the cooling system, make sure to completely flush the cooling system with clear water. Continue to flush the system until all signs of the cleaning agent are gone.
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. Open the drain valve (if equipped) or remove the cooling system drain plugs. Allow the water to drain. Flush the cooling system with clean water. If equipped, be sure to flush the heater and any related supply and return lines. Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to the Specifications Manual, SENR3130, "Torque Specifications" for more information on the proper torques. Cooling Systems with Heavy Deposits or Plugging
Note: For the following procedure to be effective, there must be some active flow through the
Caterpillar SIS machinery equipment:
Caterpillar SIS
336 Excavator YBN00001-UP (MACHINE) POWERED BY C9.3B Engine »
515-5784
VALVE GP-MAIN CONTROL
336 Excavator JHD00001-UP (MACHINE) POWERED BY C9.3B Engine »
515-5784
VALVE GP-MAIN CONTROL
336 Excavator GDY00001-UP (MACHINE) POWERED BY C9.3 Engine »
515-5784
VALVE GP-MAIN CONTROL
336 Excavator DKS00001-UP (MACHINE) POWERED BY C9.3B Engine »
515-5784
VALVE GP-MAIN CONTROL
336 Excavator SP900001-UP (MACHINE) POWERED BY C9.3 Engine »
515-5784
VALVE GP-MAIN CONTROL
340 Excavator TYH00001-UP (MACHINE) POWERED BY C9.3B Engine »
515-5784
VALVE GP-MAIN CONTROL
336 Excavator FEL00001-UP (MACHINE) POWERED BY C9.3B Engine »
515-5784
VALVE GP-MAIN CONTROL
340 Excavator WDN00001-UP (MACHINE) POWERED BY C9.3B Engine »
515-5784
VALVE GP-MAIN CONTROL
340 Excavator GMJ00001-UP (MACHINE) POWERED BY C9.3B Engine »
515-5784
VALVE GP-MAIN CONTROL
340 Excavator TMK00001-UP (MACHINE) POWERED BY C9.3B Engine »
515-5784
VALVE GP-MAIN CONTROL
340 Excavator SZT00001-UP (MACHINE) POWERED BY C9.3B Engine »
515-5784
VALVE GP-MAIN CONTROL
Caterpillar parts catalog:
Parts valve Caterpillar catalog:
5153788
VALVE & MTG GP-PILOT
Caterpillar
Caterpillar
5153092
VALVE GP-PRESSURE REDUCING
Caterpillar
Caterpillar
5152709
VALVE GP-SOLENOID & MANIFOLD
Caterpillar
Caterpillar
5149091
VALVE GP-CONTROL
Caterpillar
Caterpillar
5149090
VALVE GP-CONTROL
Caterpillar
Caterpillar
5149088
VALVE GP-CONTROL
Caterpillar
Caterpillar
5168874
VALVE GP-SOLENOID
Caterpillar
Caterpillar
5168873
VALVE GP-SOLENOID
Caterpillar
Caterpillar
5159115
VALVE GP-LUBE DISTRIBUTION
Caterpillar
Caterpillar
5156108
VALVE GP-RELIEF
Caterpillar
Caterpillar
5156104
VALVE AS-RELIEF
Caterpillar
Caterpillar
5155785
VALVE GP-MAIN CONTROL