The event code, 3546-11 for utility circuit breaker status: other failure mode is to monitor the utility breaker circuit for a change of state without a loss of utility power. The utility power is being detected by the EMCP 4 digital input. The event will become active when the following occurs:
The utility breaker opens without being tripped 3 consecutive times within 60 seconds.
Inspect system wiring for intermittent open circuits and high resistance, loose connections, and shorts to ground in between the EMCP relay output. The EMCP relay output is designated for utility breaker control to the utility breaker.Test Step 1. Check the Wiring Harness for an Open Circuit or a Short Circuit to Ground
Disconnect battery power from the engine.
Disconnect the wiring harness from the EMCP and Utility Breaker.
Measure the resistance of the wiring between the designated relay output and the utility breaker. If more than 10 ohms of resistance is found, there should be an open circuit or bad connection. Repair or replace the wiring. If less than 10 ohms of resistance is found, measure for battery voltage at the EMCP relay output pin and utility breaker connection point. If battery power is found at both points, there may be a problem with the utility breaker. If battery power is not present at the utility breaker but present at the EMCP, repair or replace the wiring harness.Results:
- STOP
The utility breaker opens without being tripped 3 consecutive times within 60 seconds.
Inspect system wiring for intermittent open circuits and high resistance, loose connections, and shorts to ground in between the EMCP relay output. The EMCP relay output is designated for utility breaker control to the utility breaker.Test Step 1. Check the Wiring Harness for an Open Circuit or a Short Circuit to Ground
Disconnect battery power from the engine.
Disconnect the wiring harness from the EMCP and Utility Breaker.
Measure the resistance of the wiring between the designated relay output and the utility breaker. If more than 10 ohms of resistance is found, there should be an open circuit or bad connection. Repair or replace the wiring. If less than 10 ohms of resistance is found, measure for battery voltage at the EMCP relay output pin and utility breaker connection point. If battery power is found at both points, there may be a problem with the utility breaker. If battery power is not present at the utility breaker but present at the EMCP, repair or replace the wiring harness.Results:
- STOP
Caterpillar parts catalog:
Parts valve Caterpillar catalog:
5189270
VALVE GP-MAIN CONTROL
Caterpillar
Caterpillar
5166828
VALVE GP-CHECK
Caterpillar
Caterpillar
5166827
VALVE AS-COUNTERBALANCE
Caterpillar
Caterpillar
5163692
VALVE
Caterpillar
Caterpillar
5162822
VALVE AS-PUMP
Caterpillar
Caterpillar
5162803
VALVE AS-PUMP
Caterpillar
Caterpillar
5208118
VALVE-SOLENOID
Caterpillar
Caterpillar
5206925
VALVE GP-AUXILIARY
Caterpillar
Caterpillar
5204715
VALVE GP-CONTROL
Caterpillar
Caterpillar
5204246
VALVE
Caterpillar
Caterpillar
5204243
VALVE-RELIEF
Caterpillar
Caterpillar
5204239
VALVE-RELIEF
Caterpillar
Caterpillar