5T5119 VALVE GP-TIRE Caterpillar parts
14G, 14H, 14H NA, 14M, R1700 II
Rating:
Alternative (cross code) number:
CA5T5119
5T-5119
5T5119
CA5T5119
5T-5119
5T5119
Weight: 0.20 pounds 0 kg.
LOAD HAUL DUMP, MOTOR GRADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 5T5119:
Information:
Initial Start-Up
Measure the insulation resistance of each winding if the generator was exposed to the following conditions:
Rapid changes in temperature
Freezing
Wet climate during shipment
Wet climate during storageRefer to this Operation and Maintenance Manual, "Insulation - Test".Note: These tests should be conducted prior to any power connections or control connections that are being made.Starting
Make all preliminary engine starting checks.
Be sure that the main circuit breaker or the line circuit breaker is open.
Start the engine. Allow the engine to warm up.
Adjust to the full load engine speed.
Close the main circuit breaker.
Apply the load. Do not try to apply the full load. Apply the load in increments in order to maintain system frequency at a constant level.
Readjust the governor for rated frequency. Adjust the Voltage
Adjust the voltage regulator in order to obtain the proper voltage. Refer to Operation and Maintenance Manual, "Voltage Regulators" for more information about the voltage regulator.
Turn the remote adjustment potentiometer to the center position, if equipped.
Connect an analog voltmeter that is calibrated for 100 VDC on terminal E+ and terminal E-.
Connect a voltmeter that is calibrated for 300 VAC to 500 VAC or 1000 VAC to the output terminals of the generator.
Make sure that the ST3 wire is positioned on the desired frequency. Also, the engine speed must be changed from the factory setting in order to change the frequency of the generator.
Turn voltage potentiometer (P2) to a full counterclockwise position.
Turn frequency potentiometer (P4) to a full clockwise position.
Turn stability potentiometer (P3) counterclockwise to about 1/3 of the total rotation for the potentiometer.
Start the engine and set the engine speed to a frequency of 48 Hz for 50 Hz or 58 Hz for 60 Hz.
Adjust the output voltage to the correct value with potentiometer P2. This voltage should be the rated voltage UN for single operation or UN plus 2% to 4% for parallel operation with a current transformer. Use potentiometer P3 to make adjustments if the voltage oscillates. Adjust potentiometer P3 in both directions while you observe the voltage between E+ and E-. The voltage between E+ and E- should be approximately 10 VDC. The best response times are obtained at the limit of the instability. Try cutting or replacing the wire ST2 if no stable position can be obtained.
Check the LAM operation. ST5 must be closed.
Turn potentiometer (P4) slowly counterclockwise until there is a significant voltage drop. The voltage drop should be approximately 15 %.
Vary the frequency around 48 Hz or 58 Hz according to the operating frequency. Check the change in the voltage that was previously observed. Stopping
Remove the load in increments.
Open the circuit breaker.
Allow the engine to run for five minutes in order to cool.
Stop the engine.
Measure the insulation resistance of each winding if the generator was exposed to the following conditions:
Rapid changes in temperature
Freezing
Wet climate during shipment
Wet climate during storageRefer to this Operation and Maintenance Manual, "Insulation - Test".Note: These tests should be conducted prior to any power connections or control connections that are being made.Starting
Make all preliminary engine starting checks.
Be sure that the main circuit breaker or the line circuit breaker is open.
Start the engine. Allow the engine to warm up.
Adjust to the full load engine speed.
Close the main circuit breaker.
Apply the load. Do not try to apply the full load. Apply the load in increments in order to maintain system frequency at a constant level.
Readjust the governor for rated frequency. Adjust the Voltage
Adjust the voltage regulator in order to obtain the proper voltage. Refer to Operation and Maintenance Manual, "Voltage Regulators" for more information about the voltage regulator.
Turn the remote adjustment potentiometer to the center position, if equipped.
Connect an analog voltmeter that is calibrated for 100 VDC on terminal E+ and terminal E-.
Connect a voltmeter that is calibrated for 300 VAC to 500 VAC or 1000 VAC to the output terminals of the generator.
Make sure that the ST3 wire is positioned on the desired frequency. Also, the engine speed must be changed from the factory setting in order to change the frequency of the generator.
Turn voltage potentiometer (P2) to a full counterclockwise position.
Turn frequency potentiometer (P4) to a full clockwise position.
Turn stability potentiometer (P3) counterclockwise to about 1/3 of the total rotation for the potentiometer.
Start the engine and set the engine speed to a frequency of 48 Hz for 50 Hz or 58 Hz for 60 Hz.
Adjust the output voltage to the correct value with potentiometer P2. This voltage should be the rated voltage UN for single operation or UN plus 2% to 4% for parallel operation with a current transformer. Use potentiometer P3 to make adjustments if the voltage oscillates. Adjust potentiometer P3 in both directions while you observe the voltage between E+ and E-. The voltage between E+ and E- should be approximately 10 VDC. The best response times are obtained at the limit of the instability. Try cutting or replacing the wire ST2 if no stable position can be obtained.
Check the LAM operation. ST5 must be closed.
Turn potentiometer (P4) slowly counterclockwise until there is a significant voltage drop. The voltage drop should be approximately 15 %.
Vary the frequency around 48 Hz or 58 Hz according to the operating frequency. Check the change in the voltage that was previously observed. Stopping
Remove the load in increments.
Open the circuit breaker.
Allow the engine to run for five minutes in order to cool.
Stop the engine.
Caterpillar parts catalog:
Parts valve Caterpillar catalog:
2391134
VALVE GP-ETHER STARTING
120K, 120K 2, 120M, 120M 2, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 140G, 140H, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14H, 14M, 160H, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 163H, 16M, 2290...
120K, 120K 2, 120M, 120M 2, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 140G, 140H, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14H, 14M, 160H, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 163H, 16M, 2290...
2G8020
VALVE GP-AIR CONTROL
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G
9N3666
VALVE-MANUAL
16G, 16H NA, 245, 245B, 307, 311, 3116, 312, 3126, 3126B, 3126E, 312D, 312D L, 314D CR, 314D LCR, 315, 317, 3176, 3176B, 3176C, 318D L, 3196, 320 L, 3208, 320D, 320D FM, 320D L, 320D LRR, 320D RR, 320...
16G, 16H NA, 245, 245B, 307, 311, 3116, 312, 3126, 3126B, 3126E, 312D, 312D L, 314D CR, 314D LCR, 315, 317, 3176, 3176B, 3176C, 318D L, 3196, 320 L, 3208, 320D, 320D FM, 320D L, 320D LRR, 320D RR, 320...
7E5346
VALVE AS
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 1673C, 16G, 16H NA, 205B, 214B, 224...
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 1673C, 16G, 16H NA, 205B, 214B, 224...
8C3446
VALVE-FLUID SAMPLING
1090, 1190, 1190T, 120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 1290T, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 1390, 140B, 140G, 140H, 140H ES, 1...
1090, 1190, 1190T, 120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 1290T, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 1390, 140B, 140G, 140H, 140H ES, 1...
1P2298
VALVE AS
120G, 12G, 130G, 140G, 14G, 1673C, 1693, 215, 215B, 225, 229, 235, 245, 3160, 3204, 3208, 330 L, 3304, 3306, 3306B, 330B, 3406, 3408, 3412, 3412C, 3516, 375, 515, 517, 518, 525, 527, 528, 54, 572G, 58...
120G, 12G, 130G, 140G, 14G, 1673C, 1693, 215, 215B, 225, 229, 235, 245, 3160, 3204, 3208, 330 L, 3304, 3306, 3306B, 330B, 3406, 3408, 3412, 3412C, 3516, 375, 515, 517, 518, 525, 527, 528, 54, 572G, 58...
6V7238
VALVE-SHUTOFF
1090, 1190, 1190T, 120K, 120K 2, 120M, 120M 2, 1290T, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 1390, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 16M, 214B, 2...
1090, 1190, 1190T, 120K, 120K 2, 120M, 120M 2, 1290T, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 1390, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 16M, 214B, 2...
8N0875
VALVE (exhaust)
140B, 14G, 1673C, 3304, 3306, 621R, 637D, 930, 951B, 966C, 977L, D4E, D6D, D7F, D7G
140B, 14G, 1673C, 3304, 3306, 621R, 637D, 930, 951B, 966C, 977L, D4E, D6D, D7F, D7G
7D6864
VALVE
120G, 12G, 130G, 14G, 16G, 621, 621B, 621R, 623, 623B, 627, 627B, 631C, 637, 641B, 650B, 651E, 657B, 657E, 666B
120G, 12G, 130G, 14G, 16G, 621, 621B, 621R, 623, 623B, 627, 627B, 631C, 637, 641B, 650B, 651E, 657B, 657E, 666B
7C0803
VALVE-PUMP BYPASS
R1700 II
R1700 II
9EL2252
VALVE
R1700 II
R1700 II
9EQ3032
VALVE-RELIEF
R1600
R1600
9EQ3031
VALVE AS-RELIEF
R1600
R1600
1868229
VALVE AS
R1300
R1300
2159313
VALVE GP-RELIEF
R1300
R1300
0083063
VALVE SLIDE SEAT & GASKET AS
R1700 II
R1700 II
0045605
VALVE GUIDE PLT
R1700 II
R1700 II
0038162
VALVE GASKET
R1700 II
R1700 II
3007181
VALVE
R1700 II
R1700 II
3007098
VALVE - CHECK
R1700 II
R1700 II
1868739
VALVE AS
R1700 II
R1700 II