GAS ENGINE, PUMPER,
You can buy:
This part in 9 request:
Show.
This information for suppliers only!
2024-03-04
2023-10-03
2023-06-25
2022-12-22
2022-11-15
2022-03-21
2021-01-20
2020-05-12
2019-10-16
Compatible equipment models: 7G8765:
Information:
Conditions Which Generate This Code:
Illustration 1 g00519201
System Schematic For Unexpected ShutdownThe purpose of the CID 0566 is to alert the operator that the GSC+ did not control the engine shutdown. The GSC+ normally controls all engine shutdown functions, for both normal operation and fault shutdowns. If an outside influence causes an engine shutdown, the GSC+ declares a CID 0566. There is only one failure mode for a CID 0566 and it is FMI 07. FMI 07 is an improper mechanical response.This diagnostic code causes the following sequence of events:
On a running engine, the GSC+ detects that engine speed has dropped from rated to 0 rpm when the GSC+ has not called for a shutdown.
The GSC+ determines that no engine speed sensor fault is present that explains the drop in speed signal.
The GSC+ declares a CID 0566 FMI 07 and disables the engine from running or starting.Note: An unexpected shutdown fault (CID 0566) will initiate a circuit breaker shunt trip signal.Note: Diagnostic codes are created when the harness connector (40 contact) is disconnected from the GSC+ during these troubleshooting procedures. Clear these created diagnostic codes after the particular diagnostic codes is corrected and cleared. The possible cause of a CID 0566 FMI 07 is a component that is not under the control of the GSC+ has caused an engine shutdown.The GSC+ treats a CID 0566 FMI 07 as a shutdown fault. Clear the diagnostic code from the fault log after troubleshooting is complete.Note: This procedure requires many voltage measurements during simulated engine cranking. Starting motor fuse F4 on the relay module is removed to prevent activating the starting motor and actual engine cranking does not occur. Voltage measurements must be made quickly before the total cycle crank time (setpoint P017) elapses. The total cycle crank time is usually 90 seconds. See Systems Operation, "Engine/Generator Programming OP5-0". If a voltage measurement takes more than 90 seconds the GSC+ declares an overcrank fault and the overcrank shutdown indicator will FLASH. In order to continue with a voltage measurement, the overcrank fault must be reset by turning the ECS to OFF/RESET and then turn the ECS to START.Test Step 1. PERFORM AN INITIAL CHECK.
Make sure that there are NO OTHER ACTIVE DIAGNOSTIC CODES. This means that there are no diagnostic codes which are showing on the upper display. This means that no shutdown or alarm indicators are flashing. Failure to make sure that there are NO OTHER ACTIVE DIAGNOSTIC CODES may result in erroneous troubleshooting and needless replacement of parts. The operator will make many voltage measurements while the GSC+ is attempting to crank the engine. If the GSC+ detects other faults, the GSC+ will prevent starting by shutting off the fuel and air to the engine. The resulting voltage measurements would then be the exact opposite of the voltage which is expected in the procedures.
Check the fuel level and quality.
Check for a plugged fuel filter.
Check for a plugged air filter.
Refer to the Service Manual for the engine if there is an obvious
Illustration 1 g00519201
System Schematic For Unexpected ShutdownThe purpose of the CID 0566 is to alert the operator that the GSC+ did not control the engine shutdown. The GSC+ normally controls all engine shutdown functions, for both normal operation and fault shutdowns. If an outside influence causes an engine shutdown, the GSC+ declares a CID 0566. There is only one failure mode for a CID 0566 and it is FMI 07. FMI 07 is an improper mechanical response.This diagnostic code causes the following sequence of events:
On a running engine, the GSC+ detects that engine speed has dropped from rated to 0 rpm when the GSC+ has not called for a shutdown.
The GSC+ determines that no engine speed sensor fault is present that explains the drop in speed signal.
The GSC+ declares a CID 0566 FMI 07 and disables the engine from running or starting.Note: An unexpected shutdown fault (CID 0566) will initiate a circuit breaker shunt trip signal.Note: Diagnostic codes are created when the harness connector (40 contact) is disconnected from the GSC+ during these troubleshooting procedures. Clear these created diagnostic codes after the particular diagnostic codes is corrected and cleared. The possible cause of a CID 0566 FMI 07 is a component that is not under the control of the GSC+ has caused an engine shutdown.The GSC+ treats a CID 0566 FMI 07 as a shutdown fault. Clear the diagnostic code from the fault log after troubleshooting is complete.Note: This procedure requires many voltage measurements during simulated engine cranking. Starting motor fuse F4 on the relay module is removed to prevent activating the starting motor and actual engine cranking does not occur. Voltage measurements must be made quickly before the total cycle crank time (setpoint P017) elapses. The total cycle crank time is usually 90 seconds. See Systems Operation, "Engine/Generator Programming OP5-0". If a voltage measurement takes more than 90 seconds the GSC+ declares an overcrank fault and the overcrank shutdown indicator will FLASH. In order to continue with a voltage measurement, the overcrank fault must be reset by turning the ECS to OFF/RESET and then turn the ECS to START.Test Step 1. PERFORM AN INITIAL CHECK.
Make sure that there are NO OTHER ACTIVE DIAGNOSTIC CODES. This means that there are no diagnostic codes which are showing on the upper display. This means that no shutdown or alarm indicators are flashing. Failure to make sure that there are NO OTHER ACTIVE DIAGNOSTIC CODES may result in erroneous troubleshooting and needless replacement of parts. The operator will make many voltage measurements while the GSC+ is attempting to crank the engine. If the GSC+ detects other faults, the GSC+ will prevent starting by shutting off the fuel and air to the engine. The resulting voltage measurements would then be the exact opposite of the voltage which is expected in the procedures.
Check the fuel level and quality.
Check for a plugged fuel filter.
Check for a plugged air filter.
Refer to the Service Manual for the engine if there is an obvious
Cat SIS web machinery list:
Parts valve Caterpillar catalog:
1227353
VALVE-INLET
G3406, G3408, G3408B, G3408C, G3412, G3412C
G3406, G3408, G3408B, G3408C, G3412, G3412C
2120932
VALVE-INLET
CG137-08, CG137-12, G3406, G3408, G3408B, G3408C, G3412, G3412C
CG137-08, CG137-12, G3406, G3408, G3408B, G3408C, G3412, G3412C
1047184
VALVE
3512, G3508, G3512, G3512E, G3516, G3516B, G3516C, G3516E, G3520B, G3520C, G3520E, PMG3516
3512, G3508, G3512, G3512E, G3516, G3516B, G3516C, G3516E, G3520B, G3520C, G3520E, PMG3516
3074641
VALVE-EXHAUST
G3508, G3508B, G3512, G3512B, G3512E, G3516, G3516B, G3516C, G3516E, G3520B, G3520C, G3520E, PMG3516
G3508, G3508B, G3512, G3512B, G3512E, G3516, G3516B, G3516C, G3516E, G3520B, G3520C, G3520E, PMG3516
1549025
VALVE-FLUID SAMPLING
120K, 120K 2, 120M, 120M 2, 12H, 12K, 12M, 140H, 140K, 140K 2, 140M, 143H, 14H, 14M, 160H, 160K, 160M, 163H, 16H, 16M, 2290, 2390, 2391, 2491, 24M, 2590, 305.5, 306, 307C, 307D, 308C, 308D, 330C, 330C...
120K, 120K 2, 120M, 120M 2, 12H, 12K, 12M, 140H, 140K, 140K 2, 140M, 143H, 14H, 14M, 160H, 160K, 160M, 163H, 16H, 16M, 2290, 2390, 2391, 2491, 24M, 2590, 305.5, 306, 307C, 307D, 308C, 308D, 330C, 330C...
1018314
VALVE-EXHAUST
G3406, G3408, G3408B, G3408C, G3412
G3406, G3408, G3408B, G3408C, G3412
2120933
VALVE-EXHAUST
CG137-08, CG137-12, G3406, G3408, G3408B, G3408C, G3412
CG137-08, CG137-12, G3406, G3408, G3408B, G3408C, G3412
8T3613
VALVE AS-PRESSURE
3176B, 3176C, 3196, 3306C, 814F, 815F, 816F, 824G, 825G, 826G, 910G, 914G, 933, 933C, 938G, 938G II, 939, 939C, 950F II, 960F, 966F II, 980F, 980F II, 980G, 992D, 994, 994D, AD40, AD45, AE40, C-10, C-...
3176B, 3176C, 3196, 3306C, 814F, 815F, 816F, 824G, 825G, 826G, 910G, 914G, 933, 933C, 938G, 938G II, 939, 939C, 950F II, 960F, 966F II, 980F, 980F II, 980G, 992D, 994, 994D, AD40, AD45, AE40, C-10, C-...
4W5374
VALVE-INLET
G3406, G3408, G3408B, G3412
G3406, G3408, G3408B, G3412
2W2443
VALVE-EXHAUST
G3406, G3408, G3408B, G3412
G3406, G3408, G3408B, G3412
6L6115
VALVE-LOAD ADJUSTMENT
G3406, G3408, G3412, G342C, G343, G353D, G379, G398, G399
G3406, G3408, G3412, G342C, G343, G353D, G379, G398, G399
6B9664
VALVE-AIR RELIEF
518, 5230, 5230B, 528, 528B, 530B, 611, 613, 613B, 613C, 613C II, 615, 615C, 621, 621B, 621E, 621F, 621G, 621R, 623, 623B, 623E, 623F, 623G, 627, 627B, 627E, 627F, 627G, 631C, 631E, 631G, 633E II, 637...
518, 5230, 5230B, 528, 528B, 530B, 611, 613, 613B, 613C, 613C II, 615, 615C, 621, 621B, 621E, 621F, 621G, 621R, 623, 623B, 623E, 623F, 623G, 627, 627B, 627E, 627F, 627G, 631C, 631E, 631G, 633E II, 637...
1778845
VALVE-RELAY
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, 3618, C280-12, C280-16, C280-6, C280-8, G3606, G3608, G3612, G3616
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, 3618, C280-12, C280-16, C280-6, C280-8, G3606, G3608, G3612, G3616
9G9364
VALVE AS
3508, 3512, 3516, 777B, 785, 789
3508, 3512, 3516, 777B, 785, 789
9X7137
VALVE AS-ETHER START
3412, 3412C, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 5130, 5230, 776C, 777B, 784B, 785, 785B, 789, 789B, 793, 793B, 994, D11N, D11R, PP3516, TH48-E80
3412, 3412C, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 5130, 5230, 776C, 777B, 784B, 785, 785B, 789, 789B, 793, 793B, 994, D11N, D11R, PP3516, TH48-E80
8C1358
VALVE-BALL
3306B, 3406C, 3406E, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, C18, C27, C32, CPT372, G3508, G3512, G3516, G3516B, G3520B, G3520C, PM3412, PM3508, PM35...
3306B, 3406C, 3406E, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, C18, C27, C32, CPT372, G3508, G3512, G3516, G3516B, G3520B, G3520C, PM3412, PM3508, PM35...
5N2746
VALVE-SOLENOID
3508, 3508B, 3512, 3516, 3516B, D399, G399
3508, 3508B, 3512, 3516, 3516B, D399, G399
5N4726
VALVE
3508, 3508C, 3512, 3512B, 3516, 3516B, 3606, 3608, 3612, 3616
3508, 3508C, 3512, 3512B, 3516, 3516B, 3606, 3608, 3612, 3616
1577125
VALVE-INLET
3116, 3126
3116, 3126
1014541
VALVE-EXHAUST
3116, 3126
3116, 3126
1013198
VALVE-INLET
3116
3116
5N8862
VALVE-PILOT
3512, 3512B, 3516, 3516B, 3606, 3608, 3612, 3616, D399, G3512, G3516, G3516B, G3520B
3512, 3512B, 3516, 3516B, 3606, 3608, 3612, 3616, D399, G3512, G3516, G3516B, G3520B
9L0672
VALVE-CHECK
120G, 12G, 130G, 140G, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, 5130B, 5230, 641B, 650B, 657B, 666B, 769C, 776, 777, 793B,...
120G, 12G, 130G, 140G, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, 5130B, 5230, 641B, 650B, 657B, 666B, 769C, 776, 777, 793B,...
4W1705
VALVE GP-DIVERTER
3508, 3512, 3512C, 3516, 3516B, D379, D379A, D379B, D398A, D398B, D399
3508, 3512, 3512C, 3516, 3516B, D379, D379A, D379B, D398A, D398B, D399