8J7501 VALVE GROUP Caterpillar parts
173B, 183B, D9H
Rating:
Alternative (cross code) number:
CA8J7501
8J-7501
8J7501
CA8J7501
8J-7501
8J7501
Weight: 215 pounds 97 kg.
HYDRAULIC CONTROL, TRACK-TYPE TRACTOR,
Information:
Which Generate This Code:The circuit breaker sensor is used by the GSC+P to determine if the generator circuit is opened or closed. When the circuit breaker sensor input is inactive the input will float to approximately 10.5 DCV. An inactive state will indicate that the circuit breaker is open. When the circuit breaker sensor input is active, the voltage level will be at the level of the battery negative terminal "B−". An active state indicates that the breaker is closed.The possible cause of a CID 1167 FMI 4 is a short from the input signal of the circuit breaker sensor to battery negative.A CID 1167 FMI 04 is detected when the input of the circuit breaker sensor is active. The CID 1167 FMI 04 indicates a closed breaker and one or both of the following items are true.
The difference of frequency between the generator and the bus is greater than 0.2 Hz.
The difference of phase between the generator and the bus is greater than 10°.When the above conditions are present for two seconds, the GSC+P will issue a CID 1167 FMI 4 as an alarm fault. The GSC+P will then stop the synchronization process until the diagnostic code is cleared and the diagnostic code is corrected.Test Step 1. CHECK THE INACTIVE VOLTAGE LEVEL OF THE CIRCUIT BREAKER SENSOR.
Turn the engine control switch (ECS) to STOP.
Locate the wire that is connecting pin 25 of the GSC+P to the terminal "B" of the "BKRR". Remove this wire at terminal "B" of the "BKRR" only. Pin 25 of GSC+P will remain connected to the wire.
Use a cable probe to measure the voltage at pin 25 of the GSC+P.Expected Result:The voltage should measure 10.5 1 DCV.Results:
OK - The voltage is 10.5 1 DCV. Proceed to Test Step 2.
NOT OK - The voltage is not within the correct range.Repair: The GSC+ may have failed. It is unlikely that the GSC+ has failed. Exit this procedure and perform this entire procedure again. If the problem remains, replace the GSC+. See Testing And Adjusting, "EMCP Electronic Control (Generator Set) - Replace". STOPTest Step 2. CHECK THE FUNCTION OF THE INPUT OF THE CIRCUIT BREAKER SENSOR.
The wire that is connecting pin 25 of the GSC+P and terminal "B" of the "BKRR" remains disconnected.
Start the engine. Adjust the engine speed so the generator frequency is more than 0.2 Hz of the frequency of the bus.
Perform the Permissive Paralling function. Refer to Systems Operation, "Synchronization Sequence Of Operation".
Ensure that the synchroscope is present on the lower display of the GSC+P.
Touch the loose end of the wire of pin 25 of the GSC+P to the battery negative terminal "B−".Expected Result:After two seconds, the CID 1167 FMI 4 should be active.Results:
OK - The GSC+P issues the diagnostic.Repair: The GSC+P is operating correctly, and the problem is in the wiring or the component that is connected to the input of the circuit breaker sensor. Use the FMI information and use the Close Breaker Input System Schematic to find the
The difference of frequency between the generator and the bus is greater than 0.2 Hz.
The difference of phase between the generator and the bus is greater than 10°.When the above conditions are present for two seconds, the GSC+P will issue a CID 1167 FMI 4 as an alarm fault. The GSC+P will then stop the synchronization process until the diagnostic code is cleared and the diagnostic code is corrected.Test Step 1. CHECK THE INACTIVE VOLTAGE LEVEL OF THE CIRCUIT BREAKER SENSOR.
Turn the engine control switch (ECS) to STOP.
Locate the wire that is connecting pin 25 of the GSC+P to the terminal "B" of the "BKRR". Remove this wire at terminal "B" of the "BKRR" only. Pin 25 of GSC+P will remain connected to the wire.
Use a cable probe to measure the voltage at pin 25 of the GSC+P.Expected Result:The voltage should measure 10.5 1 DCV.Results:
OK - The voltage is 10.5 1 DCV. Proceed to Test Step 2.
NOT OK - The voltage is not within the correct range.Repair: The GSC+ may have failed. It is unlikely that the GSC+ has failed. Exit this procedure and perform this entire procedure again. If the problem remains, replace the GSC+. See Testing And Adjusting, "EMCP Electronic Control (Generator Set) - Replace". STOPTest Step 2. CHECK THE FUNCTION OF THE INPUT OF THE CIRCUIT BREAKER SENSOR.
The wire that is connecting pin 25 of the GSC+P and terminal "B" of the "BKRR" remains disconnected.
Start the engine. Adjust the engine speed so the generator frequency is more than 0.2 Hz of the frequency of the bus.
Perform the Permissive Paralling function. Refer to Systems Operation, "Synchronization Sequence Of Operation".
Ensure that the synchroscope is present on the lower display of the GSC+P.
Touch the loose end of the wire of pin 25 of the GSC+P to the battery negative terminal "B−".Expected Result:After two seconds, the CID 1167 FMI 4 should be active.Results:
OK - The GSC+P issues the diagnostic.Repair: The GSC+P is operating correctly, and the problem is in the wiring or the component that is connected to the input of the circuit breaker sensor. Use the FMI information and use the Close Breaker Input System Schematic to find the
Caterpillar parts catalog:
Parts valve Caterpillar catalog:
5D0470
VALVE GP-QUICK RELEASE
120G, 12G, 130G, 140G, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA, 613, 613C, 613C II, 621, 621E, 621F, 621G, 623E, 623F, 623G, 627E, 627F, 627G, 631C, 631D, 631E, 631G, 633C, 633D, 633E II, 637, 637D, ...
120G, 12G, 130G, 140G, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA, 613, 613C, 613C II, 621, 621E, 621F, 621G, 623E, 623F, 623G, 627E, 627F, 627G, 631C, 631D, 631E, 631G, 633C, 633D, 633E II, 637, 637D, ...
3P7665
VALVE GP-RELIEF
571G, 572G, 583K, 594, 594H, D7F, D7G, D8H, D8K, D9G, D9H
571G, 572G, 583K, 594, 594H, D7F, D7G, D8H, D8K, D9G, D9H
9N3666
VALVE-MANUAL
16G, 16H NA, 245, 245B, 307, 311, 3116, 312, 3126, 3126B, 3126E, 312D, 312D L, 314D CR, 314D LCR, 315, 317, 3176, 3176B, 3176C, 318D L, 3196, 320 L, 3208, 320D, 320D FM, 320D L, 320D LRR, 320D RR, 320...
16G, 16H NA, 245, 245B, 307, 311, 3116, 312, 3126, 3126B, 3126E, 312D, 312D L, 314D CR, 314D LCR, 315, 317, 3176, 3176B, 3176C, 318D L, 3196, 320 L, 3208, 320D, 320D FM, 320D L, 320D LRR, 320D RR, 320...
2R0618
VALVE AS-CHECK
621, 621B, 621R, 623, 623B, 627, 627B, 631C, 631D, 633C, 633D, 637, 637D, 639D, 641, 641B, 650B, 651, 651B, 657, 657B, 666, 666B, D9G, D9H
621, 621B, 621R, 623, 623B, 627, 627B, 631C, 631D, 633C, 633D, 637, 637D, 639D, 641, 641B, 650B, 651, 651B, 657, 657B, 666, 666B, D9G, D9H
8F8151
VALVE-SHUTOFF
1090, 1190, 1190T, 120, 120B, 120G, 120H, 120H ES, 120H NA, 1290T, 12F, 12G, 12H, 12H NA, 130G, 135H, 135H NA, 1390, 140, 140B, 140G, 140H, 140H NA, 143H, 14E, 14H, 16, 160H, 163H, 16G, 16H NA, 16M, 2...
1090, 1190, 1190T, 120, 120B, 120G, 120H, 120H ES, 120H NA, 1290T, 12F, 12G, 12H, 12H NA, 130G, 135H, 135H NA, 1390, 140, 140B, 140G, 140H, 140H NA, 143H, 14E, 14H, 16, 160H, 163H, 16G, 16H NA, 16M, 2...
8F8858
VALVE
3508, 3508B, 3508C, 3512, 3516, 3516B, 5130, 5230, 594, 776C, 784B, 785, 785B, 789B, 793B, 994, D11N, D11R, D326F, D337, D337F, D353C, D379, D379A, D379B, D398, D398A, D398B, D399, D9E, D9G, D9H, G350...
3508, 3508B, 3508C, 3512, 3516, 3516B, 5130, 5230, 594, 776C, 784B, 785, 785B, 789B, 793B, 994, D11N, D11R, D326F, D337, D337F, D353C, D379, D379A, D379B, D398, D398A, D398B, D399, D9E, D9G, D9H, G350...
2S5100
VALVE-MANUAL
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
7M7817
VALVE INLET
594, D353C, D379, D379A, D379B, D398, D398A, D398B, D399, D9G, D9H, G353D, G379, G398, G399
594, D353C, D379, D379A, D379B, D398, D398A, D398B, D399, D9G, D9H, G353D, G379, G398, G399
1P1098
VALVE SERVICE GROUP
D353C, D379, D398, D9G, D9H
D353C, D379, D398, D9G, D9H
5M5962
VALVE
594, D326F, D353C, D9E, D9G, D9H
594, D326F, D353C, D9E, D9G, D9H
1J8497
VALVE
120G, 12E, 12G, 140, 14E, 14G, 16, 163, 172, 173B, 183, 183B, 191, 225, 245, 307, 312, 315, 317, 325B, 330 L, 350, 350 L, 375, 41, 44, 46, 5080, 517, 518, 518C, 527, 528, 528B, 530B, 561C, 561H, 561M,...
120G, 12E, 12G, 140, 14E, 14G, 16, 163, 172, 173B, 183, 183B, 191, 225, 245, 307, 312, 315, 317, 325B, 330 L, 350, 350 L, 375, 41, 44, 46, 5080, 517, 518, 518C, 527, 528, 528B, 530B, 561C, 561H, 561M,...
2S8571
VALVE
561D, 572G, 583K, 594, 594H, 977L, 983, 983B, D5B, D5E, D6D, D6E, D6E SR, D6F SR, D6G, D6G SR, D6G2 LGP, D6G2 XL, D7G, D7G2, D8H, D8K, D9G, D9H
561D, 572G, 583K, 594, 594H, 977L, 983, 983B, D5B, D5E, D6D, D6E, D6E SR, D6F SR, D6G, D6G SR, D6G2 LGP, D6G2 XL, D7G, D7G2, D8H, D8K, D9G, D9H
2P4042
VALVE (R.H.)
977K, 977L
977K, 977L
2P4041
VALVE (L.H.)
977K, 977L
977K, 977L
9S6919
VALVE ASSEM.
641B, 777, 977K
641B, 777, 977K
2J7415
VALVE
183, 184, 977K, D7F, D8H, D9G
183, 184, 977K, D7F, D8H, D9G
6S3440
VALVE
910, D3
910, D3
6S6907
VALVE
931, 931B
931, 931B
6S8748
VALVE ASSEM.
931, 931B
931, 931B
8J8480
VALVE
173B, 183B, D7G, D8K, D9H
173B, 183B, D7G, D8K, D9H
9J4029
VALVE
173B, 183B, D7G, D8K, D8L, D9H, D9L
173B, 183B, D7G, D8K, D8L, D9H, D9L
8J7349
VALVE
173B, 183B, D7G, D8K, D8L, D9H, D9L
173B, 183B, D7G, D8K, D8L, D9H, D9L
8J7436
VALVE GROUP
173B, 183B, D7G, D8K, D9H
173B, 183B, D7G, D8K, D9H