Information:
Redundant (N+1) Option
A redundant (N+1) system is sized with an additional MMU. In the MMU configuration, the loss of one MMU will not cause the system to drop the critical load. The malfunction of one MMU will cause the MMU with the fault to be disconnected from the critical load. The remaining units will continue to carry the load. After the MMU has been repaired, the unit can be reconnected to the critical load. The system can then resume redundant operation.There will be an automatic transfer of the load to bypass without an interruption of the power if both of the following conditions exist:
If more than one MMU is removed from the system
If the load exceeds the capacity of the units that are remaining on-lineAny redundant units can be taken off the critical load manually for maintenance without disturbing the critical load bus. In this case, the isolation switches are used.Systems without a Redundant MMU
In a system without a redundant MMU, all the units will supply the full rated load. If the units malfunction, there will be a transfer of the load to the bypass line without an interruption of power. Any MMU can be taken off the critical load manually for maintenance without disturbing the critical load bus.Load Sharing
In parallel operation, all of the inverter units automatically share the load at all times. The output current of individual units will be no more than 15% unbalanced. The parallel load sharing function is programmed within each MMU. In (N+1) systems, the redundant MMU only shares the reactive current.Selective Tripping
Each MMU has a self-diagnostic capability. If a failure of an MMU occurs, the faulty MMU will be removed from the critical bus. Selective tripping does not rely on information that is shared among units.Manual Load Transfers
A manual load transfer can be initiated from the control panel of the system cabinet. The manual load transfer can be made between the output of the UPS and the alternate bypass AC source.A manual load transfer between the output of the UPS and the alternate bypass AC source can be initiated from the control panel of the system cabinet. Manually initiated transfers will make the connection to the alternate bypass AC source before breaking the connection. The transfers utilize the output of the UPS and the bypass circuit breaker (system).Automatic Load Transfers
An automatic load transfer between the outputs of the inverter and the alternate bypass AC source is initiated for the following reasons:
If an overload condition is sustained for a time period in excess of the capability of the system output
A malfunction that would affect the output voltageThe following rule applies to transfers that are caused by overloads.
Automatic transfer of the load back to the system will occur after the load has returned to a level within the rating of the UPS. The internal programming of the UPS allows a transfer of the load back to the UPS up to three times. Transfers of the UPS back to the system are adjustable within
A redundant (N+1) system is sized with an additional MMU. In the MMU configuration, the loss of one MMU will not cause the system to drop the critical load. The malfunction of one MMU will cause the MMU with the fault to be disconnected from the critical load. The remaining units will continue to carry the load. After the MMU has been repaired, the unit can be reconnected to the critical load. The system can then resume redundant operation.There will be an automatic transfer of the load to bypass without an interruption of the power if both of the following conditions exist:
If more than one MMU is removed from the system
If the load exceeds the capacity of the units that are remaining on-lineAny redundant units can be taken off the critical load manually for maintenance without disturbing the critical load bus. In this case, the isolation switches are used.Systems without a Redundant MMU
In a system without a redundant MMU, all the units will supply the full rated load. If the units malfunction, there will be a transfer of the load to the bypass line without an interruption of power. Any MMU can be taken off the critical load manually for maintenance without disturbing the critical load bus.Load Sharing
In parallel operation, all of the inverter units automatically share the load at all times. The output current of individual units will be no more than 15% unbalanced. The parallel load sharing function is programmed within each MMU. In (N+1) systems, the redundant MMU only shares the reactive current.Selective Tripping
Each MMU has a self-diagnostic capability. If a failure of an MMU occurs, the faulty MMU will be removed from the critical bus. Selective tripping does not rely on information that is shared among units.Manual Load Transfers
A manual load transfer can be initiated from the control panel of the system cabinet. The manual load transfer can be made between the output of the UPS and the alternate bypass AC source.A manual load transfer between the output of the UPS and the alternate bypass AC source can be initiated from the control panel of the system cabinet. Manually initiated transfers will make the connection to the alternate bypass AC source before breaking the connection. The transfers utilize the output of the UPS and the bypass circuit breaker (system).Automatic Load Transfers
An automatic load transfer between the outputs of the inverter and the alternate bypass AC source is initiated for the following reasons:
If an overload condition is sustained for a time period in excess of the capability of the system output
A malfunction that would affect the output voltageThe following rule applies to transfers that are caused by overloads.
Automatic transfer of the load back to the system will occur after the load has returned to a level within the rating of the UPS. The internal programming of the UPS allows a transfer of the load back to the UPS up to three times. Transfers of the UPS back to the system are adjustable within
Caterpillar SIS machinery equipment:
Caterpillar SIS
120G MOTOR GRADER 11W01019-01250 (MACHINE) POWERED BY 3304 ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
120G MOTOR GRADER 11W01019-01250 (MACHINE) POWERED BY 3304 ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
130G MOTOR GRADER 12W00696-01081 (MACHINE) POWERED BY 3304 ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
130G MOTOR GRADER 12W00696-01081 (MACHINE) POWERED BY 3304 ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
140G MOTOR GRADER 13W00425-00740 (MACHINE) POWERED BY 3306DI ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
140G MOTOR GRADER 13W00425-00740 (MACHINE) POWERED BY 3306DI ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
12G MOTOR GRADER 3WC00001-01066 (MACHINE) POWERED BY 3306 ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
120G Motor Grader 11W01251-UP (MACHINE) POWERED BY 3304 Engine »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
130G MOTOR GRADER 12W01082-UP (MACHINE) POWERED BY 3304 ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
140G Motor Grader 13W00741-00992 (MACHINE) POWERED BY 3306 Engine »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
120G MOTOR GRADER 82V00668-UP (MACHINE) POWERED BY 3304 ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
12G MOTOR GRADER 61M02629-07710 (MACHINE) POWERED BY 3306 ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
140G MOTOR GRADER 72V00823-04230 (MACHINE) POWERED BY 3306 ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
12G MOTOR GRADER 61M07711-12026 (MACHINE) POWERED BY 3306 ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
12G MOTOR GRADER 61M07711-12026 (MACHINE) POWERED BY 3306 ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
140G MOTOR GRADER 72V04231-10333 (MACHINE) POWERED BY 3306 ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
140G MOTOR GRADER 72V04231-10333 (MACHINE) POWERED BY 3306 ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
130G MOTOR GRADER 74V01657-02058 (MACHINE) POWERED BY 3304 ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
130G MOTOR GRADER 74V01657-02058 (MACHINE) POWERED BY 3304 ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
120G MOTOR GRADERS 87V05275-08359 (MACHINE) POWERED BY 3304 ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
120G MOTOR GRADERS 87V05275-08359 (MACHINE) POWERED BY 3304 ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
130G MOTOR GRADER 74V02059-02320 (MACHINE) POWERED BY 3304 ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
160G MOTOR GRADER 4JD00001-00140 (MACHINE) POWERED BY 3306DI ENGINE »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
140G Motor Grader 72V10334-UP (MACHINE) POWERED BY 3306 Engine »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
120G Motor Grader 87V08360-UP (MACHINE) POWERED BY 3304 Engine »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
12G Motor Grader 61M12027-UP (MACHINE) POWERED BY 3306 Engine »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
130G Motor Grader 74V02321-UP (MACHINE) POWERED BY 3304 Engine »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
120G Motor Grader 4HD00001-UP (MACHINE) POWERED BY 3304 Engine »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
140G Motor Grader 5MD00001-UP (MACHINE) POWERED BY 3306 Engine »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
12G Motor Grader 3WC01067-UP (MACHINE) POWERED BY 3306 Engine »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
160G Motor Grader 4JD00141-UP (MACHINE) POWERED BY 3306 Engine »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
12G Motor Grader 3PL00001-UP (MACHINE) POWERED BY 3306 Engine »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
130G MOTOR GRADER 7GB01224-UP (MACHINE) »
8P-1101
VALVE GP-SELECTOR & PRESS CONT
Caterpillar parts catalog:
Parts valve Caterpillar catalog:
6V2526
VALVE GRINDING
12G, 140G, 3306, 561D, D5B
12G, 140G, 3306, 561D, D5B
6V0600
VALVE GRINDING- SERIAL NO. 78P34523 TO 78P47087 INCLUSIVE
120G, 130G, 3304, 920, 930, 950, 955L, D4D, D4E
120G, 130G, 3304, 920, 930, 950, 955L, D4D, D4E
6V2971
VALVE GRINDING
140G, 14G, 528, 561D, D5B, D6D
140G, 14G, 528, 561D, D5B, D6D
2G1034
VALVE-AIR RELIEF
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 143H, 14G, 14H, 14H NA, 14M, 160G, 160H, 16...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 143H, 14G, 14H, 14H NA, 14M, 160G, 160H, 16...
2G3537
VALVE-RELAY
120G, 12G, 130G, 140G, 14G, 16G, 611, 615, 615C, 621, 621B, 623E, 627B, 631D, 633D, 637D, 641B, 651B, 651E, 657B, 657E, 768C, 769C, 772B, 773B
120G, 12G, 130G, 140G, 14G, 16G, 611, 615, 615C, 621, 621B, 623E, 627B, 631D, 633D, 637D, 641B, 651B, 651E, 657B, 657E, 768C, 769C, 772B, 773B
6D1432
VALVE-CHECK
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 160K, ...
7D6864
VALVE
120G, 12G, 130G, 14G, 16G, 621, 621B, 621R, 623, 623B, 627, 627B, 631C, 637, 641B, 650B, 651E, 657B, 657E, 666B
120G, 12G, 130G, 14G, 16G, 621, 621B, 621R, 623, 623B, 627, 627B, 631C, 637, 641B, 650B, 651E, 657B, 657E, 666B
8M3368
VALVE-CHECK
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 130G, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 143H, 14G, 14H NA, 14M, 160G, 160H, 160H ES, 160H NA, 1...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 130G, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 143H, 14G, 14H NA, 14M, 160G, 160H, 160H ES, 160H NA, 1...
9D1289
VALVE
120G, 12G, 130G, 140G, 14G, 160G, 16G, 611, 613C, 613C II, 615C, 621, 627E, 631C, 633D, 769C, 769D, 771C, 771D, 772, 773B, 773D, 773E, 775B, 775D, 775E, 776, 776C, 777D, 784B, 784C, 785, 785B, 785C, 7...
120G, 12G, 130G, 140G, 14G, 160G, 16G, 611, 613C, 613C II, 615C, 621, 627E, 631C, 633D, 769C, 769D, 771C, 771D, 772, 773B, 773D, 773E, 775B, 775D, 775E, 776, 776C, 777D, 784B, 784C, 785, 785B, 785C, 7...
3D2239
VALVE AS-TIRE
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 130G, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 160H, 160K, 160M...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 130G, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 160H, 160K, 160M...
4D1138
VALVE
120G, 120H, 12G, 12H, 12H NA, 130G, 135H, 140G, 140H, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 163H, 16G, 16H, 16H NA, 5110B, 518, 5230, 5230B, 528, 621B, 631C, 633C, 639D, 666, 769, 769C, 769D, 7...
120G, 120H, 12G, 12H, 12H NA, 130G, 135H, 140G, 140H, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 163H, 16G, 16H, 16H NA, 5110B, 518, 5230, 5230B, 528, 621B, 631C, 633C, 639D, 666, 769, 769C, 769D, 7...
4D2004
VALVE ASSEM.
120G, 650B, 666, 768B, 768C, 769, 769C, 771D, 988B, 992, AD30, AD45, AD45B, AE40 II, R1600, R1600G, R1600H, R1700 II, R1700G, R2900, R2900G
120G, 650B, 666, 768B, 768C, 769, 769C, 771D, 988B, 992, AD30, AD45, AD45B, AE40 II, R1600, R1600G, R1600H, R1700 II, R1700G, R2900, R2900G
6T4531
VALVE & MOUNTING GP
D10N, D11N, D8L, D8N, D8R, D9L, D9N
D10N, D11N, D8L, D8N, D8R, D9L, D9N
3882450
VALVE GP-MANUAL
966H, 972H
966H, 972H
9J8096
VALVE GP-RELIEF
245, 245B, 639D
245, 245B, 639D
1588202
VALVE GP-CONTROL
320C, 320C FM
320C, 320C FM
2224741
VALVE GP-SOLENOID
769C, 769D, 770, 771C, 771D, 772, 773B, 773D, 773E, 773F, 775D, 775E, 775F, 777D, 777F, 784B, 784C, 785B, 785C, 785D, 789B, 789C, 789D, 793B, 793C, 793D, 793F, 793F CMD, 793F OEM, 793F-XQ, 797, 797B, ...
769C, 769D, 770, 771C, 771D, 772, 773B, 773D, 773E, 773F, 775D, 775E, 775F, 777D, 777F, 784B, 784C, 785B, 785C, 785D, 789B, 789C, 789D, 793B, 793C, 793D, 793F, 793F CMD, 793F OEM, 793F-XQ, 797, 797B, ...
3E8574
VALVE GP-SOLENOID
515, 525, 844, 950G, 953C, 962G, 966G, 972G, 980G, 990, 990 II, D11R, IT28F, IT62G
515, 525, 844, 950G, 953C, 962G, 966G, 972G, 980G, 990, 990 II, D11R, IT28F, IT62G
1602451
VALVE GP-CONTROL
AP-1000B, AP-1055B, AP-655C, AP-900B, BG-2455C, BG-245C, PM-465
AP-1000B, AP-1055B, AP-655C, AP-900B, BG-2455C, BG-245C, PM-465
1922901
VALVE GP-MOTOR CONTROL
320C, 320D FM, 543, HF181, HF201, HF201B, HF202, HF221, HF222, SC-57, SH-56B, SS-56
320C, 320D FM, 543, HF181, HF201, HF201B, HF202, HF221, HF222, SC-57, SH-56B, SS-56
2577732
VALVE GP-MAKEUP
450E, 450F, 953D, D5R LGP, D6K, D6K LGP, D6K XL, D6K2, D6K2 LGP, D6N, D6N LGP
450E, 450F, 953D, D5R LGP, D6K, D6K LGP, D6K XL, D6K2, D6K2 LGP, D6N, D6N LGP
1067389
VALVE GP-RELIEF
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H, 135H NA, 140H, 140H ES, 140H NA, 143H, 14H NA, 160H, 160H ES, 160H NA, 163H NA, 16H NA
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H, 135H NA, 140H, 140H ES, 140H NA, 143H, 14H NA, 160H, 160H ES, 160H NA, 163H NA, 16H NA
9T2138
VALVE GP-CONTROL
120G, 12G, 130G, 140G, 14G
120G, 12G, 130G, 140G, 14G