9J3393 VALVE GP-CHECK & RELIEF Caterpillar parts
215, 235, 235B, 235C
Rating:
Alternative (cross code) number:
CA9J3393
9J-3393
9J3393
CA9J3393
9J-3393
9J3393
Weight: 1 pounds 0 kg.
EXCAVATOR,
Caterpillar SIS machinery equipment:
Caterpillar SIS
215 EXCAVATOR 96L00001-00786 (MACHINE) POWERED BY 3304 ENGINE »
9J-3393
VALVE GP-CHECK & RELIEF
215 EXCAVATOR 57Y00001-UP (MACHINE) POWERED BY 3402 ENGINE »
9J-3393
VALVE GP-CHECK
235 EXCAVATOR 64R01258-UP (MACHINE) POWERED BY 3306 ENGINE »
9J-3393
VALVE GP-CHECK & RELIEF
235 EXCAVATOR 83X00444-UP (MACHINE) POWERED BY 3306 ENGINE »
9J-3393
VALVE GP-CHECK
235B EXCAVATOR 4ED00001-UP (MACHINE) POWERED BY 3306 ENGINE »
9J-3393
VALVE GP-CHECK
215 EXCAVATOR 96L00787-UP (MACHINE) POWERED BY 3304 ENGINE »
9J-3393
VALVE GP-CHECK & RELIEF
215 EXCAVATOR 96L00787-UP (MACHINE) POWERED BY 3304 ENGINE »
9J-3393
VALVE GP-CHECK & RELIEF
235 EXCAVATOR 32K02679-UP (MACHINE) POWERED BY 3306 ENGINE »
9J-3393
VALVE GP-CHECK
235 EXCAVATOR 81X00404-UP (MACHINE) POWERED BY 3306 ENGINE »
9J-3393
VALVE GP-CHECK & RELIEF
215 EXCAVATOR 14Z00001-00648 (MACHINE) POWERED BY 3204 ENGINE »
9J-3393
VALVE GP-CHECK
235B EXCAVATOR 1FD00001-UP (MACHINE) POWERED BY 3306 ENGINE »
9J-3393
VALVE GP-CHECK
235C EXCAVATOR 2PG00001-UP (MACHINE) POWERED BY 3306 ENGINE »
9J-3393
VALVE GP-CHECK & RELIEF
Caterpillar parts catalog:
Information:
is the option for entering the password that is required for accessing OP4 through OP10. Service mode options OP4 through OP10 are password protected. This reduces the possibility of information being altered by mistake. Options OP1 and OP2 are for the viewing of information. Options OP1 and OP2 are not password protected. Password entry consists of actuating the scroll keys in the correct sequence. The password is identical for every GSC. The password cannot be changed. After the password is entered, the OP4 through OP10 options can be accessed. If a mistake is made during password entry, "FAIL" is briefly shown on the upper display. Pressing the "SELECT" key starts the password entry process again. Procedure To Enter The Password
Note: Service mode cannot be entered when the ECS is in the AUTO position.Note: Any active shutdown fault must be made inactive in order to access service mode. A FLASHING shutdown indicator means that a shutdown fault exists. To temporarily change a shutdown fault from an active shutdown fault to an inactive shutdown fault, turn the ECS to the OFF/RESET position. To permanently change a shutdown fault from an active shutdown fault to an inactive shutdown fault, the fault must not be occurring. Also, the ECS must be turned to the OFF/RESET position. If the jumper from terminal 6 to terminal 9 is not installed on the ECS, then the GSC will not power up in OFF/RESET and any active shutdown fault must be corrected before entering service mode.
Press "SERVICE MODE" key in order to enter service mode. "OP 1" is showing on the lower display. See Systems Operation, "Service Mode" for more information.
Press "SCROLL UP" key twice. "OP 3" is showing.
Press "SELECT" key. "PE _ _ _ _ _" is showing.
Press "SELECT" key. "PE _ _ _ _ _" is showing and the first dash is flashing.
Press "SCROLL RIGHT" key. "PE 1 _ _ _ _ " is showing and the next dash is flashing.
Press "SCROLL DOWN" key. "PE 1 3 _ _ _ " is showing and the next dash is flashing.
Press "SCROLL UP" key. "PE 1 3 2 _ _" is showing and the next dash is flashing.
Press "SCROLL DOWN" key. "PE 1 3 2 3 _ " is showing and the last dash is flashing.
Press "SCROLL RIGHT" key. "PE 1 3 2 3 1 " is showing.
Press "ENTER" key. "PE PASS" is showing.
Press "EXIT" key. "OP 1" is showing. Note: After the password is entered, any option can be accessed. Options can be accessed repeatedly. The password remains in effect until service mode is exited. If the operator attempts to enter the password twice, "PE PASS" reappears on the lower display.
Note: Service mode cannot be entered when the ECS is in the AUTO position.Note: Any active shutdown fault must be made inactive in order to access service mode. A FLASHING shutdown indicator means that a shutdown fault exists. To temporarily change a shutdown fault from an active shutdown fault to an inactive shutdown fault, turn the ECS to the OFF/RESET position. To permanently change a shutdown fault from an active shutdown fault to an inactive shutdown fault, the fault must not be occurring. Also, the ECS must be turned to the OFF/RESET position. If the jumper from terminal 6 to terminal 9 is not installed on the ECS, then the GSC will not power up in OFF/RESET and any active shutdown fault must be corrected before entering service mode.
Press "SERVICE MODE" key in order to enter service mode. "OP 1" is showing on the lower display. See Systems Operation, "Service Mode" for more information.
Press "SCROLL UP" key twice. "OP 3" is showing.
Press "SELECT" key. "PE _ _ _ _ _" is showing.
Press "SELECT" key. "PE _ _ _ _ _" is showing and the first dash is flashing.
Press "SCROLL RIGHT" key. "PE 1 _ _ _ _ " is showing and the next dash is flashing.
Press "SCROLL DOWN" key. "PE 1 3 _ _ _ " is showing and the next dash is flashing.
Press "SCROLL UP" key. "PE 1 3 2 _ _" is showing and the next dash is flashing.
Press "SCROLL DOWN" key. "PE 1 3 2 3 _ " is showing and the last dash is flashing.
Press "SCROLL RIGHT" key. "PE 1 3 2 3 1 " is showing.
Press "ENTER" key. "PE PASS" is showing.
Press "EXIT" key. "OP 1" is showing. Note: After the password is entered, any option can be accessed. Options can be accessed repeatedly. The password remains in effect until service mode is exited. If the operator attempts to enter the password twice, "PE PASS" reappears on the lower display.
Parts valve Caterpillar catalog:
4204598
VALVE & LINES GP-CONTROL
M322D, M322D MH
M322D, M322D MH
7G9570
VALVE GP-SELECTOR & PRESS CONT
824C, 825C, 826C, 834B, 980C, 980F, 988B, D35HP, D400, D44B, D550B
824C, 825C, 826C, 834B, 980C, 980F, 988B, D35HP, D400, D44B, D550B
1129634
VALVE GP-DIVERTER
824G, 980G
824G, 980G
2090273
VALVE GP-MAIN CONTROL
924G, 924GZ, 924H, 924HZ
924G, 924GZ, 924H, 924HZ
2070695
VALVE GP-PUMP CONTROL
554, 834H, 836H, 966G II, 972G II, 980G, 980G II, 980H, 988H
554, 834H, 836H, 966G II, 972G II, 980G, 980G II, 980H, 988H
4390479
VALVE GP-PUMP CONTROL
M316D, M318D, M318D MH, M322D MH
M316D, M318D, M318D MH, M322D MH
4I1024
VALVE GP-BRAKE
320, 320 L, 320N, 322, 322 FM L, 322 LN, 325, 325 L, 325 LN, 330, 330 FM L, 330 L, 350, 375, 375 L, 5080, TK1051
320, 320 L, 320N, 322, 322 FM L, 322 LN, 325, 325 L, 325 LN, 330, 330 FM L, 330 L, 350, 375, 375 L, 5080, TK1051
6E3037
VALVE GP-CONTROL
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H NA, 12K, 135H, 135H NA, 140H, 140H NA, 140K, 140K 2, 143H, 160H, 160H NA, 160K, 163H, 163H NA
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H NA, 12K, 135H, 135H NA, 140H, 140H NA, 140K, 140K 2, 143H, 160H, 160H NA, 160K, 163H, 163H NA
8E6398
VALVE GP-SELECTOR
824G, 825G, 826G, 844, 844H, 844K, 854G, 854K, 980F, 980F II, 980G, 980G II, 988F, 988F II, 990, 990 II, 990H, 990K, 992D, 992G, 992K, 993K, D11R, D11T, R2900, R2900G, R3000H
824G, 825G, 826G, 844, 844H, 844K, 854G, 854K, 980F, 980F II, 980G, 980G II, 988F, 988F II, 990, 990 II, 990H, 990K, 992D, 992G, 992K, 993K, D11R, D11T, R2900, R2900G, R3000H
2865605
VALVE GP-LUBE DISTRIBUTION
773F, 775F
773F, 775F