Information:
Illustration 1 g01256020
Schematic of transmission solenoid 1This diagnostic code is associated with transmission solenoid 1. The FMI 05 means that the Power Train ECM has determined that the current of the solenoid is below normal. The possible causes of this diagnostic code are:
The energize circuit of the solenoid is open.
The return circuit of the solenoid is open.
The solenoid has failed.
The ECM has failed. This is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1401 FMI 05 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:When this diagnostic code occurs, only the gears that use the solenoids that have faults are not available.Test Step 1. CHECK THE SOLENOID
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Disconnect the solenoid from the machine harness.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire 751-GN) to contact 2 (wire 975-WH).
Observe the status of the CID 1401 FMI 05.Expected Result:The CID 1401 FMI 05 remains active.Results:
YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code. Proceed to Test Step 2.
NO - The diagnostic code is no longer active. The solenoid has failed.Repair: Replace the solenoid. Verify that the new solenoid corrects the problem.STOPTest Step 2. CHECK THE HARNESS FOR AN OPEN CIRCUIT
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connector(s) from the ECM.
The jumper wire that was installed in the previous Test Step remains in place.
At the machine harness connector, measure the resistance from signal contact J1-65 (wire 751-GN) to contacts J1-50 (wire 975-WH).Expected Result:The resistance is less than 5 ohms.Results:
YES - The resistance is less than 5 ohms. The machine harness is correct. Proceed to Test Step 3.
NO - The resistance is greater than 5 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.Repair: The open circuit is in wire 751-GN or in wire 975-WH of the machine harness. Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS
Inspect the contacts of the harness connectors and clean the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 1401 FMI 05.Expected Result:The CID 1401 FMI 05 is active. Results:
YES - The CID 1401 FMI 05 is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. Refer to Troubleshooting, Testing and Adjusting, "Electronic Control Module (ECM) - Replace". STOP
NO - The CID 1401 FMI 05 is
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts vandalism Caterpillar catalog:
4V0112
VANDALISM PROTECTION GROUP
824B, 825B, 826B
824B, 825B, 826B
4V0116
VANDALISM PROTECTION GROUP
824B, 825B, 826B