2S6168 VEE BELT SET Caterpillar parts
657, 657B
Rating:
Alternative (cross code) number:
CA2S6168
2S-6168
2S6168
CA2S6168
2S-6168
2S6168
Weight: 3 pounds 1 kg.
WHEEL SCRAPER,
Compare Prices:
As an associate, we earn commssions on qualifying purchases through the links below
$71.50
19 May 2023
US: Florida-Parts-Z
2S6168 - VEE Belt Set (3 Belts) for Caterpillar (CAT)
FIRST PRICE PARTS
FIRST PRICE PARTS
$66.22
16 Apr 2023
Amazon.com
CTP 2S6168 External Engine V-Belt, 15/16" Size, 77.5" Length, Pack of 3
CTP For External engine || 15/16" Size || 77.5" Length || Pack of 3
CTP For External engine || 15/16" Size || 77.5" Length || Pack of 3
Information:
Chapter 1. General Information
Description
The 9905/9907 series of the Woodward 2301A controls load sharing and speed of generators driven by diesel or gasoline engines, or steam or gas turbines. These power sources are referred to as "prime movers" throughout this manual.The control is housed in a sheet-metal chassis and consists of a single printed circuit board. All potentiometers are accessible from the front of the chassis.The 2301A provides control in either isochronous or droop mode.The isochronous mode is used for constant prime mover speed with:* Single-prime-mover operation;* Two or more prime movers controlled by Woodward load sharing control systems on an isolated bus;* Base loading against an infinite bus with the load controlled by an Automatic Power Transfer and Load (APTL) Control, an Import/Export Control, a Generator Loading Control, a Process Control, or another load-controlling accessory.The droop mode is used for speed control as a function of load with:* Single-prime-mover operation on an infinite bus or* Parallel operation of two or more prime movers.The following is an example of the typical hardware needed for the 2301A system controlling a single prime-mover and generator:* A 2301A electronic control* An external 20 to 40 Vdc power source for low-voltage models; 90 to 150 Vdc or 88 to 132 Vac for high-voltage models* A proportional actuator to position the fuel-metering device, and* Current and potential transformers for measuring the load carried by the generator.Applications
The 2301A 9905/9907 series electronic controls have switch-selectable speed ranges. Any of these control models can be set to operate within one of the following rated speed ranges: * 500 to 1500 Hz* 1000 to 3000 Hz* 2000 to 6000 Hz* 4000 to 12000 Hz
-OVERSPEEDThe speed range is factory set for 2000 to 6000 Hz. Refer to the inside cover to change speed range and prevent possible overspeed. Using the wrong speed range could cause an overspeed with resulting damage to equipment and/or personal injury or death.
CAUTION-DO NOT TURN POTS BEYOND THEIR STOPSThe Rated Speed potentiometer is the only multi-turn pots in this control. All other pots are single-turn. Take care not to turn these pots beyond their stops.
These controls are available for forward- or reverse-acting applications, and for use with either single or tandem actuators. Models for three different actuator current ranges are available, as well as high-voltage model (90 to 150 Vdc or 88 to 132 Vac, 45 to 440 Hz), and a low-voltage model (20 to 40 Vdc). The high voltage model is identified as such on the front, the low voltage model is not.In reverse-acting systems, the actuator calls for more fuel when the actuator voltage decreases. Complete loss of voltage to the actuator will drive the actuator to full fuel. This allows a backup mechanical ballhead governor to take control rather than shut down the prime mover as would a direct-acting system.An optional deceleration ramp is also offered. When this option is present, the time to ramp from rated speed to idle speed is approximately 20 seconds. If this option is not present, this
Description
The 9905/9907 series of the Woodward 2301A controls load sharing and speed of generators driven by diesel or gasoline engines, or steam or gas turbines. These power sources are referred to as "prime movers" throughout this manual.The control is housed in a sheet-metal chassis and consists of a single printed circuit board. All potentiometers are accessible from the front of the chassis.The 2301A provides control in either isochronous or droop mode.The isochronous mode is used for constant prime mover speed with:* Single-prime-mover operation;* Two or more prime movers controlled by Woodward load sharing control systems on an isolated bus;* Base loading against an infinite bus with the load controlled by an Automatic Power Transfer and Load (APTL) Control, an Import/Export Control, a Generator Loading Control, a Process Control, or another load-controlling accessory.The droop mode is used for speed control as a function of load with:* Single-prime-mover operation on an infinite bus or* Parallel operation of two or more prime movers.The following is an example of the typical hardware needed for the 2301A system controlling a single prime-mover and generator:* A 2301A electronic control* An external 20 to 40 Vdc power source for low-voltage models; 90 to 150 Vdc or 88 to 132 Vac for high-voltage models* A proportional actuator to position the fuel-metering device, and* Current and potential transformers for measuring the load carried by the generator.Applications
The 2301A 9905/9907 series electronic controls have switch-selectable speed ranges. Any of these control models can be set to operate within one of the following rated speed ranges: * 500 to 1500 Hz* 1000 to 3000 Hz* 2000 to 6000 Hz* 4000 to 12000 Hz
-OVERSPEEDThe speed range is factory set for 2000 to 6000 Hz. Refer to the inside cover to change speed range and prevent possible overspeed. Using the wrong speed range could cause an overspeed with resulting damage to equipment and/or personal injury or death.
CAUTION-DO NOT TURN POTS BEYOND THEIR STOPSThe Rated Speed potentiometer is the only multi-turn pots in this control. All other pots are single-turn. Take care not to turn these pots beyond their stops.
These controls are available for forward- or reverse-acting applications, and for use with either single or tandem actuators. Models for three different actuator current ranges are available, as well as high-voltage model (90 to 150 Vdc or 88 to 132 Vac, 45 to 440 Hz), and a low-voltage model (20 to 40 Vdc). The high voltage model is identified as such on the front, the low voltage model is not.In reverse-acting systems, the actuator calls for more fuel when the actuator voltage decreases. Complete loss of voltage to the actuator will drive the actuator to full fuel. This allows a backup mechanical ballhead governor to take control rather than shut down the prime mover as would a direct-acting system.An optional deceleration ramp is also offered. When this option is present, the time to ramp from rated speed to idle speed is approximately 20 seconds. If this option is not present, this
Caterpillar parts catalog:
Parts vee Caterpillar catalog:
9M2420
VEE BELT SET
657, 988
657, 988
8S4653
VEE BELT
641, 666
641, 666
4M6292
VEE BELT
651, 666
651, 666
5M0924
VEE BELT
641B, D40D
641B, D40D
2S6913
VEE BELT SET
641, 651, 666
641, 651, 666
9M5146
VEE BELT
651, 657
651, 657
2P6161
VEE BELT
641B, 772, 773
641B, 772, 773
4N4759
VEE BELT SET
631C
631C
2P8720
VEE BELT
641B, 772
641B, 772