2P2886 WASHER Caterpillar parts
120G, 12G, 14G, 16G, 627B, 637D, 768B, 772, D7G
Rating:
Alternative (cross code) number:
CA2P2886
2P-2886
2P2886
CA2P2886
2P-2886
2P2886
Weight: 2 pounds 0 kg.
MOTOR GRADER, WHEEL SCRAPER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$9.51
05 Jan 2024
US: Florida-Parts-Z
8E8304 - DISC Thrust 6T7799 6P5005 2P2886 7M5731 7G0894 fits Caterpillar (CAT)
FIRST PRICE PARTS
FIRST PRICE PARTS
$9.64
01 Dec 2023
US: Florida-Parts-Z
6P5005 - DISC - Washer 6T7799 8E8304 2P2886 7G0894 7M5731 fits Caterpillar (CAT)
FIRST PRICE PARTS
FIRST PRICE PARTS
Compatible equipment models: 2P2886:
Information:
Integrated Voltage Regulator (IVR) General Information
The EMCP integrated voltage regulator (IVR) feature is a substitute for a traditional voltage regulator configuration. The traditional voltage regulator configuration consists of a dedicated controller such as a Cat Digital Voltage Regulator (CDVR) or a VR6.The EMCP 4 internal controller regulates generator output voltage. The voltage is regulated by sending a command to the excitation module (EM10/EM15). The excitation module controls generator excitation and therefore generator output voltage.The IVR feature is available with revised EMCP 4.3 and EMCP 4.4 controllers with software version 4.3PROD and above. The capability does NOT exist in original EMCP 4.3 and EMCP 4.4 controllers, regardless of software version.
Illustration 1 g03486261
EMCPintegrated voltage regulator (IVR) system
IVR Features for EMCP 4.3 and EMCP 4.4
The following functionality is available when an EMCP 4.3 or EMCP 4.4 possesses IVR logic and is used with an excitation module (EM):
Automatic voltage regulation (AVR)
Programmable stability settings
Soft start control with an adjustable time setting in AVR control mode
Dual slope, under frequency (Volts/Hz) regulation that can be configured
Three-phase or single-phase generator voltage (RMS) sensing/regulation in AVR mode
Set point configuration adjustment from the EMCP display or Cat® Electronic Technician (Cat ET) Service Tool
Voltage output adjustment via display, analog input, digital input, or SCADA (Modbus)
IVR operating status and voltage bias overview screens to provide an enhanced level of user interface
Integrated voltage regulator event monitoring
Power factor regulation (PF) (EMCP 4.4 only)
Reactive droop compensation (EMCP 4.4 only)
Line drop compensation (EMCP 4.4 only)Hardware Installation
EMCP IVR Connections
To regulate the generator terminal voltage, the EMCP communicates the desired excitation command to the excitation module via a pulse width modulation PWM signal. A twisted pair shielded cable must be used for the communication link. Table 1 details the connections to be made between the EMCP and excitation module.
Table 1
EMCP 4.3 and EMCP 4.4 Connections to Excitation Module
EMCP 4.3, EMCP 4.4 70-Pin Connector Excitation Module 3-Pin Connector
Digital Output #2 / IVR CS+ 68 CS+ P3-2
Battery negative splice 60 or 65 CS- P3-3
Battery negative splice 60 or 65 Shield P3-1 IVR Excitation Module
The IVR consists of an EMCP 4 that is interface with an excitation module.
Illustration 2 g03487518
EM10 and EM15 excitation modules
Table 2 provides information on the technical specification of the EM10 and EM15 modules. Selection of the appropriate module must be determined by the following:
Nominal and maximum generator excitation current at full load (standby, 0.8PF)
The maximum AC voltage input
Table 2
EM10 and EM15 Technical Specifications
EM10 EM15
Compatible Generator Excitation Types Permanent Magnet (PM)
Self-Excitation (SE)
Internal Excitation (IE/AREP)(1)
Nominal Field Current Output 6 A 7 A
Maximum (forcing) Field Current Output 10 A 15 A
Maximum AC Voltage Input 180 Vrms 240 Vrms
Exciter Field Resistance (recommended) 6 to 16 ohms
(1) Internal Excitation (IE is also referred to as "Auxiliary Regulation Excitation Principle" (AREP).Details for nominal field current are available on the generator data sheet. For self-excited (shunt) generators, users must understand the connections between the generator winding and the excitation module to understand the maximum AC voltage input. Caterpillar recommends that an intermediate, half-phase to neutral connection be used for self-excited generators.IVR Excitation Module Physical Layout
The
The EMCP integrated voltage regulator (IVR) feature is a substitute for a traditional voltage regulator configuration. The traditional voltage regulator configuration consists of a dedicated controller such as a Cat Digital Voltage Regulator (CDVR) or a VR6.The EMCP 4 internal controller regulates generator output voltage. The voltage is regulated by sending a command to the excitation module (EM10/EM15). The excitation module controls generator excitation and therefore generator output voltage.The IVR feature is available with revised EMCP 4.3 and EMCP 4.4 controllers with software version 4.3PROD and above. The capability does NOT exist in original EMCP 4.3 and EMCP 4.4 controllers, regardless of software version.
Illustration 1 g03486261
EMCPintegrated voltage regulator (IVR) system
IVR Features for EMCP 4.3 and EMCP 4.4
The following functionality is available when an EMCP 4.3 or EMCP 4.4 possesses IVR logic and is used with an excitation module (EM):
Automatic voltage regulation (AVR)
Programmable stability settings
Soft start control with an adjustable time setting in AVR control mode
Dual slope, under frequency (Volts/Hz) regulation that can be configured
Three-phase or single-phase generator voltage (RMS) sensing/regulation in AVR mode
Set point configuration adjustment from the EMCP display or Cat® Electronic Technician (Cat ET) Service Tool
Voltage output adjustment via display, analog input, digital input, or SCADA (Modbus)
IVR operating status and voltage bias overview screens to provide an enhanced level of user interface
Integrated voltage regulator event monitoring
Power factor regulation (PF) (EMCP 4.4 only)
Reactive droop compensation (EMCP 4.4 only)
Line drop compensation (EMCP 4.4 only)Hardware Installation
EMCP IVR Connections
To regulate the generator terminal voltage, the EMCP communicates the desired excitation command to the excitation module via a pulse width modulation PWM signal. A twisted pair shielded cable must be used for the communication link. Table 1 details the connections to be made between the EMCP and excitation module.
Table 1
EMCP 4.3 and EMCP 4.4 Connections to Excitation Module
EMCP 4.3, EMCP 4.4 70-Pin Connector Excitation Module 3-Pin Connector
Digital Output #2 / IVR CS+ 68 CS+ P3-2
Battery negative splice 60 or 65 CS- P3-3
Battery negative splice 60 or 65 Shield P3-1 IVR Excitation Module
The IVR consists of an EMCP 4 that is interface with an excitation module.
Illustration 2 g03487518
EM10 and EM15 excitation modules
Table 2 provides information on the technical specification of the EM10 and EM15 modules. Selection of the appropriate module must be determined by the following:
Nominal and maximum generator excitation current at full load (standby, 0.8PF)
The maximum AC voltage input
Table 2
EM10 and EM15 Technical Specifications
EM10 EM15
Compatible Generator Excitation Types Permanent Magnet (PM)
Self-Excitation (SE)
Internal Excitation (IE/AREP)(1)
Nominal Field Current Output 6 A 7 A
Maximum (forcing) Field Current Output 10 A 15 A
Maximum AC Voltage Input 180 Vrms 240 Vrms
Exciter Field Resistance (recommended) 6 to 16 ohms
(1) Internal Excitation (IE is also referred to as "Auxiliary Regulation Excitation Principle" (AREP).Details for nominal field current are available on the generator data sheet. For self-excited (shunt) generators, users must understand the connections between the generator winding and the excitation module to understand the maximum AC voltage input. Caterpillar recommends that an intermediate, half-phase to neutral connection be used for self-excited generators.IVR Excitation Module Physical Layout
The
Caterpillar parts catalog:
Parts washer Caterpillar catalog:
0M0393
WASHER-NOTCHED
120, 120G, 130G
120, 120G, 130G
8D5378
WASHER
14G, 14H, 14H NA
14G, 14H, 14H NA
8D5362
WASHER
14G, 14H, 14H NA
14G, 14H, 14H NA
6G3207
WASHER-THRUST
14G, 14H, 14H NA, 14M
14G, 14H, 14H NA, 14M
2G0339
WASHER-SPECIAL
14G, 14H, 14H NA, 14M, 16G, 16H, 16H NA, 16M, 24H, 24M
14G, 14H, 14H NA, 14M, 16G, 16H, 16H NA, 16M, 24H, 24M
6G3208
WASHER-THRUST
16G, 16H, 16H NA
16G, 16H, 16H NA
8X8378
WASHER
16G, 16H, 16H NA, 16M
16G, 16H, 16H NA, 16M
8D9076
WASHER-THRUST
12G, 130G, 140G, 14G
12G, 130G, 140G, 14G
6D2361
WASHER
120B, 120G, 12F, 12G, 130G, 140, 140B, 14E, 14G
120B, 120G, 12F, 12G, 130G, 140, 140B, 14E, 14G
9D9967
WASHER
14G
14G
8D8627
WASHER
120G
120G
7D8438
WASHER
12G, 130G, 14G, 16G
12G, 130G, 14G, 16G
0005894
WASHER
941, D4E, D5, D5B, D6D
941, D4E, D5, D5B, D6D
7N2540
WASHER
D9H
D9H
8J3519
WASHER
D5B, D6C
D5B, D6C
9J4449
WASHER
8D, D7H, D8K, D8L, D9N
8D, D7H, D8K, D8L, D9N
3P9363
WASHER
583K, D7G, D8K
583K, D7G, D8K
2K1723
WASHER
572G, 594, 594H
572G, 594, 594H
8P9251
WASHER 4 mm(.157 in.) thick
977L, 983B
977L, 983B
5P0845
WASHER
561D
561D
5B5271
WASHER
D5B, D6D
D5B, D6D
6S7631
WASHER
931, 931B, D3B
931, 931B, D3B
3V3307
WASHER
824C, 825C, 943, 955K, 955L, 980B, 988B
824C, 825C, 943, 955K, 955L, 980B, 988B
1K4697
WASHER
571G
571G