6J9747 WASHER Caterpillar parts
7A, 7S, D7G, D7H, D7R, D7R II, D7R XR, D8N, D8R, D8R II, D8T, D9N, D9R, D9T
Rating:
Alternative (cross code) number:
CA6J9747
6J-9747
6J9747
CA6J9747
6J-9747
6J9747
Weight: 1 pounds 0 kg.
Information:
ID
53
mm
MATERIAL
Steel - Carbon
MATL THK
12.7
mm
OD
105
mm
BULLDOZER, TRACK-TYPE TRACTOR,
Compatible equipment models: 6J9747:
Information:
The diagnostic code for the special instruction is logged in order to report the configuration status of the data link. The diagnostic code for the special instruction does not check the physical condition of the data link.The following list identifies possible faults on the data link:
Incorrect personality module code
An invalid configuration parameter
Incorrect module or display on the data link
Damaged data link wiring
Incompatible software in the ECM or ISMUse this procedure in order to troubleshoot a diagnostic code for a special instruction. Also, use this procedure if the following diagnostic code is active.
Table 1
Diagnostic Codes Table
J1939 Code and Description Conditions which Generate this Code System Response
234-14
Software Identification : Special Instruction The Electronic Control Module (ECM) and Integrated Sensing Module (ISM) software files are not compatible.
A power cycle is required after a software update. The code is logged.
Table 2
Troubleshooting Test Steps Values Results
1. Check for an Associated -9 Code
A. Establish communication between the electronic service tool and the Electronic Control Module (ECM) for the engine.
B. Download a "Warranty Report" from the engine ECM before performing any troubleshooting or clearing diagnostic trouble codes.
C. Check for active diagnostic codes.
Associated Code
Result: An associated -9 code is logged.
Repair: Repair all associated -9 codes before continuing with this procedure. Refer to Troubleshooting, "Data Link - Test".
If a -14 code is still present after resolving the -9 code, proceed to Test Step 2.
Result: An associated -9 code is not logged.
Proceed to Test Step 2.
2. Check the Personality Module Code for Compatibility with the Application
A. Connect to the electronic service tool.
B. Select the ECM or ISM connection that is related to the logged code.
C. Check if the personality module code is valid for the application.
Compatible Personality Module
Result: The code is valid for the application.
Proceed to Test Step 3.
Result: The code is not valid for the application.
Repair: Obtain the correct flash file and update the ECM or ISM. Reset all active codes and clear all logged codes. Return the unit to service.
3. Check the Configuration Parameters
A. Check the configuration parameters in order to ensure that the parameters are programmed correctly. Refer to Troubleshooting, "Configuration Parameters".
B. Select the ECM connection that is related to the logged code.
Correct Configuration Parameters
Result: The configuration parameters are programmed correctly.
Proceed to Test Step 4.
Result: The configuration parameters are not programmed correctly.
Repair: Program the parameters to function with the other modules on the data link. Reset all active codes and clear all logged codes. Return the unit to service.
4. Check for Compatibility with the ECM and the ISM on the Data Link
A. Use the as shipped information found in SIS web TMI to determine if any other ECM or display on the data link are incompatible.
B. Select the ECM connection that is related to the logged code.
Compatible ECM and ISM
Result: The ECM and ISM are not compatible.
Repair: Replace the incompatible ECM or ISM with the correct module. Reset all active codes and clear all logged codes. Return the unit to service.
Incorrect personality module code
An invalid configuration parameter
Incorrect module or display on the data link
Damaged data link wiring
Incompatible software in the ECM or ISMUse this procedure in order to troubleshoot a diagnostic code for a special instruction. Also, use this procedure if the following diagnostic code is active.
Table 1
Diagnostic Codes Table
J1939 Code and Description Conditions which Generate this Code System Response
234-14
Software Identification : Special Instruction The Electronic Control Module (ECM) and Integrated Sensing Module (ISM) software files are not compatible.
A power cycle is required after a software update. The code is logged.
Table 2
Troubleshooting Test Steps Values Results
1. Check for an Associated -9 Code
A. Establish communication between the electronic service tool and the Electronic Control Module (ECM) for the engine.
B. Download a "Warranty Report" from the engine ECM before performing any troubleshooting or clearing diagnostic trouble codes.
C. Check for active diagnostic codes.
Associated Code
Result: An associated -9 code is logged.
Repair: Repair all associated -9 codes before continuing with this procedure. Refer to Troubleshooting, "Data Link - Test".
If a -14 code is still present after resolving the -9 code, proceed to Test Step 2.
Result: An associated -9 code is not logged.
Proceed to Test Step 2.
2. Check the Personality Module Code for Compatibility with the Application
A. Connect to the electronic service tool.
B. Select the ECM or ISM connection that is related to the logged code.
C. Check if the personality module code is valid for the application.
Compatible Personality Module
Result: The code is valid for the application.
Proceed to Test Step 3.
Result: The code is not valid for the application.
Repair: Obtain the correct flash file and update the ECM or ISM. Reset all active codes and clear all logged codes. Return the unit to service.
3. Check the Configuration Parameters
A. Check the configuration parameters in order to ensure that the parameters are programmed correctly. Refer to Troubleshooting, "Configuration Parameters".
B. Select the ECM connection that is related to the logged code.
Correct Configuration Parameters
Result: The configuration parameters are programmed correctly.
Proceed to Test Step 4.
Result: The configuration parameters are not programmed correctly.
Repair: Program the parameters to function with the other modules on the data link. Reset all active codes and clear all logged codes. Return the unit to service.
4. Check for Compatibility with the ECM and the ISM on the Data Link
A. Use the as shipped information found in SIS web TMI to determine if any other ECM or display on the data link are incompatible.
B. Select the ECM connection that is related to the logged code.
Compatible ECM and ISM
Result: The ECM and ISM are not compatible.
Repair: Replace the incompatible ECM or ISM with the correct module. Reset all active codes and clear all logged codes. Return the unit to service.
Cat SIS web machinery list:
Parts washer Caterpillar catalog:
8M3999
WASHER-THRUST
561B, 561C, D4D, D4E, D4E SR, D5, D5B, D5E, D6C, D6D, D6E SR, D7F, D7G
561B, 561C, D4D, D4E, D4E SR, D5, D5B, D5E, D6C, D6D, D6E SR, D7F, D7G
3H2645
WASHER
561B, 561C, 955C, 977D, D4D, D4E, D4E SR, D5, D5B, D5E, D6C, D6D, D6E SR, D7F, D7G
561B, 561C, 955C, 977D, D4D, D4E, D4E SR, D5, D5B, D5E, D6C, D6D, D6E SR, D7F, D7G
9G9341
WASHER-THRUST
973, D7H, D8L, D9N
973, D7H, D8L, D9N
6Y5010
WASHER
120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H,...
120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H,...
8P1958
WASHER-THRUST
572G, 613C, 613C II, 613G, 621, 621B, 621E, 621F, 621G, 621H, 621K, 621R, 623B, 623E, 623F, 623G, 623H, 623K, 623K LRC, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC, 631C, 631E, 631G, 633C, 633D, 633E...
572G, 613C, 613C II, 613G, 621, 621B, 621E, 621F, 621G, 621H, 621K, 621R, 623B, 623E, 623F, 623G, 623H, 623K, 623K LRC, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC, 631C, 631E, 631G, 633C, 633D, 633E...
1198455
WASHER
854G, D10N, D10R, D10T, D9N, D9R, D9T
854G, D10N, D10R, D10T, D9N, D9R, D9T
2S6313
WASHER
571G, 572G, 977H, D7F, D7G, D7G2
571G, 572G, 977H, D7F, D7G, D7G2
2P2887
WASHER
14G, 16G, 57, 58, 621B, 621R, 627B, 633D, 637D, 814, 950, 955K, 966C, D7G, D8H, D8K, D9G, D9H
14G, 16G, 57, 58, 621B, 621R, 627B, 633D, 637D, 814, 950, 955K, 966C, D7G, D8H, D8K, D9G, D9H
9J4449
WASHER
8D, D7H, D8K, D8L, D9N
8D, D7H, D8K, D8L, D9N
2P2886
WASHER
120G, 12G, 14G, 16G, 627B, 637D, 768B, 772, D7G
120G, 12G, 14G, 16G, 627B, 637D, 768B, 772, D7G
6V2360
WASHER
130G, 518, 611, 613C, 613C II, 613G, 615, 615C, 621, 621B, 621R, 627B, 657E, 735, 735B, 740, 740B, 773G, 773G OEM, 775G, 775G OEM, 776C, 776D, 777B, 777D, 777F, 777G, 784B, 784C, 785, 785B, 785C, 785D...
130G, 518, 611, 613C, 613C II, 613G, 615, 615C, 621, 621B, 621R, 627B, 657E, 735, 735B, 740, 740B, 773G, 773G OEM, 775G, 775G OEM, 776C, 776D, 777B, 777D, 777F, 777G, 784B, 784C, 785, 785B, 785C, 785D...
1A2557
WASHER
D6H, D7H, D8N
D6H, D7H, D8N
1198455
WASHER
854G, D10N, D10R, D10T, D9N, D9R, D9T
854G, D10N, D10R, D10T, D9N, D9R, D9T
8E8215
WASHER-THRUST
D9R, D9T
D9R, D9T
2485135
WASHER
D3K2 LGP, D4K2 XL, D5K2 XL
D3K2 LGP, D4K2 XL, D5K2 XL
3914691
WASHER
PL83, PL87
PL83, PL87
3914687
WASHER
PL83, PL87
PL83, PL87
1605277
WASHER
PL83, PL87
PL83, PL87
5J7173
WASHER-BOLT
173B, 183B, D8H, D9G
173B, 183B, D8H, D9G
4K2370
WASHER
955H, 977H
955H, 977H
6F6976
WASHER
941, 951B, 955C
941, 951B, 955C
2993424
WASHER-HARD
621G, 623G, 627G, 770, 770G, 770G OEM, 772, 772G, 772G OEM, 777G, 797B, 797F, D10T2, D6T LGP, D6T LGPPAT, D8T, D9T
621G, 623G, 627G, 770, 770G, 770G OEM, 772, 772G, 772G OEM, 777G, 797B, 797F, D10T2, D6T LGP, D6T LGPPAT, D8T, D9T
8R9645
WASHER
773F, 775F, 993K, AP1000E, AP1055E, BG1000E, BG1055E, D6T LGP, D6T LGPPAT
773F, 775F, 993K, AP1000E, AP1055E, BG1000E, BG1055E, D6T LGP, D6T LGPPAT
4545385
WASHER-HARD
D6R STD