1318237 WATER PUMP GROUP Caterpillar parts
924F
Rating:
Alternative (cross code) number:
CA1318237
131-8237
1318237
CA1318237
131-8237
1318237
Weight: 14 pounds 6 kg.
WHEEL LOADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Zuide 7C6438 Water Pump for Cat 1318237 AP-1000 AP-1000B
Zuide Item Name: Water Pump || Part Number: 7C6438 7C-6438 || Package included:1 Pcs Water Pump || Professional installation is highly recommended. || please ask to us if you have any questions with this item
Zuide Item Name: Water Pump || Part Number: 7C6438 7C-6438 || Package included:1 Pcs Water Pump || Professional installation is highly recommended. || please ask to us if you have any questions with this item
Geofrey Water Pump 7C6438 7C-6438 Compatible with Cat 1318237 AP-1000 AP-1000B AP-1050 AP-1050B
Geofrey Item Name: Water Pump || Part Number: 7C6438 7C-6438 || Condition: New || Manufacturer Warranty: 6 Months || Compatible with Cat 1318237 AP-1000 AP-1000B AP-1050 AP-1050B
Geofrey Item Name: Water Pump || Part Number: 7C6438 7C-6438 || Condition: New || Manufacturer Warranty: 6 Months || Compatible with Cat 1318237 AP-1000 AP-1000B AP-1050 AP-1050B
$272.16
11 Mar 2024
CN: Cebadan
Geofrey Water Pump 7C6438 7C-6438 Compatible with Cat 1318237 AP-1000 AP-1000B AP-1050 AP-1050B
Geofrey Item Name: Water Pump || Part Number: 7C6438 7C-6438 || Condition: New || Manufacturer Warranty: 6 Months || Compatible with Cat 1318237 AP-1000 AP-1000B AP-1050 AP-1050B
Geofrey Item Name: Water Pump || Part Number: 7C6438 7C-6438 || Condition: New || Manufacturer Warranty: 6 Months || Compatible with Cat 1318237 AP-1000 AP-1000B AP-1050 AP-1050B
Compatible equipment models: 1318237:
Information:
Three Phase
The connections for high and low voltage and delta are given in the following diagrams.The terminals must be connected securely and insulated with a good quality electrical tape.
Typical High Voltage (Series Wye) Connection (60 Hz)
Typical Low Voltage (Parallel Wye) Connection (60 Hz)
Typical Delta Connection (60 Hz)Single Phase Current From a Three-Phase Generator
Three phase and single phase current can be taken simultaneously from a generator connected for three phase service. Connecting the load to any two of the three phase leads in both Wye and Delta configurations will provide single phase voltage at the same voltage as three phase power. Connecting the load to any phase lead and neutral of the Wye configuration will produce voltage at 58% of three phase voltage. In the Delta configuration producing 240 volt 60 Hz three phase power, the high phase to neutral would produce 208 volts and either low phase to neutral would produce voltage at 120 volts of three phase voltage.Single phase power taken from a three phase source can be a problem unless the single phase loading is equally distributed.Do not exceed the nameplate current rating for any one phase.
Single Phase Voltage Using Wye Configuration
Single Phase Voltage Using Delta Configuration
The connections for high and low voltage and delta are given in the following diagrams.The terminals must be connected securely and insulated with a good quality electrical tape.
Typical High Voltage (Series Wye) Connection (60 Hz)
Typical Low Voltage (Parallel Wye) Connection (60 Hz)
Typical Delta Connection (60 Hz)Single Phase Current From a Three-Phase Generator
Three phase and single phase current can be taken simultaneously from a generator connected for three phase service. Connecting the load to any two of the three phase leads in both Wye and Delta configurations will provide single phase voltage at the same voltage as three phase power. Connecting the load to any phase lead and neutral of the Wye configuration will produce voltage at 58% of three phase voltage. In the Delta configuration producing 240 volt 60 Hz three phase power, the high phase to neutral would produce 208 volts and either low phase to neutral would produce voltage at 120 volts of three phase voltage.Single phase power taken from a three phase source can be a problem unless the single phase loading is equally distributed.Do not exceed the nameplate current rating for any one phase.
Single Phase Voltage Using Wye Configuration
Single Phase Voltage Using Delta Configuration
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts water Caterpillar catalog:
1318238
WATER PUMP GROUP
938F, 938G, 950G, 962G, D5M, D6M
938F, 938G, 950G, 962G, D5M, D6M
2M7894
WATER PUMP GROUP
583H, D342, D8H
583H, D342, D8H
1167967
WATER PUMP
330B, 330B L, D6R, D7R
330B, 330B L, D6R, D7R
4L8797
WATER COOLED EXHAUST MANIFOLD GROUP
D379, D379A
D379, D379A
6L3146
WATER LINES
D343
D343
6N9940
WATER SEPARATOR GROUP
561C, D5
561C, D5