AVSPARE.COM
parts catalog

WATER PUMP 7S1222 - Caterpillar


7S1222 WATER PUMP Caterpillar parts 641B, 650B, 657B, 666B, 772, 773, 992, D346, D348, D349
Rating:
65
Alternative (cross code) number:
CA7S1222
7S-1222
7S1222
Caterpillar 7S1222 WATER PUMP
Weight: 0.55 pounds 0 kg.

Buy WATER PUMP 7S1222 Caterpillar genuine, new aftermarket tractor parts with delivery
TRACTOR, WHEEL TRACTOR,

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
$45.45
 

17 Jul 2019
200 Hundredths Pounds
CTP: CTP
Caterpillar GROUP-WATER PUMP O/H (7S1222)
Warranty
 

19 Dec 2017
200 Hundredths Pounds
CTP: CTP
7S1222 Group-Water Pump O/H Fits Caterpillar D346 D348 D349 772 773 992 992B
Warranty
  For full view, you need register

Compatible equipment models: 7S1222:

TRACTOR  772  
TRUCK  773  
VEHICULAR ENGINE  D346   D348   D349  
WHEEL LOADER  992  
WHEEL TRACTOR  641B   650B   657B   666B   Caterpillar

Information:


Check for the proper version of the regulator.
Check the part number of the digital voltage regulator. Refer to the chart in Testing And Adjusting, "Troubleshooting". Check whether the digital voltage regulator is proper for the application.Expected Result: The digital voltage regulator is proper for the application.Results:
OK: Go to Step 2.
NOT OK: Install the proper digital voltage regulator. STOP.
Check the status of the display.
Stop the generator set.
Observe the display on the digital voltage regulator.Expected Result: The display should contain a number.Results:
OK: Proceed to Step 4.
NOT OK: No number is present on the display. Proceed to Step 3.
Check the DC voltage.
Check for proper DC voltage from terminal "B+" to "B-". The acceptable voltage range is 18 VDC to 32 VDC.Expected Result: The sufficient DC voltage is present.Results:
OK: The sufficient DC voltage is present. Remove the DC power wires from terminals "B+" and "B-" for 30 seconds. Reconnect the DC power wires to the "B+" and "B-" terminals. If the display of the regulator is still blank, the regulator is faulty. Then, the regulator needs to be replaced. If this condition has occured, verify that the correct burden resistor or the rheostat is connected between the droop current transformer and the regulator. If no resistor is present, the regulator was destroyed because of high current on the CT input. Refer to Testing And Adjusting, "Wiring Diagrams". STOP.
NOT OK: The sufficient DC voltage is not present. Repair the supply voltage wiring, fuses and circuit breakers, if necessary. STOP.
Verify the proper configuration of the parameters.Parameters :10 or :13 must not be set too high.
If the underfrequency point (parameter :10) is set too close to the nominal operating frequency, then the voltage may not build. Look for an undervoltage fault code. If the code is found, try the default value.
If the undervoltage trip point (parameter :13) is set too close to the nominal operating voltage, the voltage regulator may shutdown and report an undervoltage fault code. Try the default value.
Display the number in parameters :92, :93, and :95 (if present). A display of "0000" indicates no faults. If a fault code is present, see System Operation, "Parameters".Expected Result: The problem has been resolved.Results:
OK: The problem has been resolved. STOP.
NOT OK: The problem has not been resolved. Proceed to Step 5.
Check the PM inputs.
Turn the engine off.
Check that all of the digital voltage regulator connections are tight and properly made per the appropriate wiring diagram.
Check PM fuses (connecting to terminals 26 and 30 of the digital voltage regulator).
Restart the engine.
Check the PM inputs (26, 28, and 30) of the digital voltage regulator. Measure the AC voltage between terminals 26 to 28, 28 to 30, and 26 to 30.
If the digital voltage regulator is connected as a self-excited regulator, check if the power transformers are properly wired as an open delta configuration for the according wiring diagrams. Check if the power transformers are properly sized in order to provide a minimum of 1200 VA each.Expected Result: The proper voltage is approximately 95 VAC for 60 Hertz

Caterpillar parts catalog:

Caterpillar parts catalog
D346 VEHICULAR ENGINE 98N00001-UP
D348 VEHICULAR ENGINE 57K00001-UP
D349 VEHICULAR ENGINE 32R00001-UP
772 TRACTOR 11S00001-UP (MACHINE)
773 TRUCK 63G00001-00339 (MACHINE)
772 TRACTOR 80S00001-UP (MACHINE)
773 TRUCK 63G00340-UP (MACHINE) POWERED BY D346 ENGINE
641B & 651B TRACTORS 65K00985-UP (MACHINE) POWERED BY D346 ENGINE
992 WHEEL LOADER 25K00001-00698 (MACHINE)
650B & 660B TRACTORS 58K00001-UP (MACHINE)
666B TRACTOR 66K00001-UP (MACHINE) POWERED BY D346 ENGINE
657B TRACTOR 68K00001-00892 (MACHINE)
641B & 651B TRACTORS 65K00001-00984 (MACHINE)
657B TRACTOR 68K00893-UP (MACHINE) POWERED BY D346 ENGINE


Parts water Caterpillar catalog:

6V3745 WATER LINES
D379B, D398B, D399
5P5724 WATER PUMP
641B, 650B, 657B, 666B, 772, 773, D346, D349, D4H, D4HTSK II
Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.