Information:
Configuration
The thermocouple module will remain fully functional during single set point configuration and also during communications on the data link.
Even if the communication link is terminated, the thermocouple module will continue to operate normally.
All configured values and error codes are stored in non-volatile memory. Non-volatile memory allows retention of all parameter values and error codes when the thermocouple module is de-energized.
The thermocouple module is configured on the secondary data link (CAN2). Configuration is accomplished by using the Cat Service Tool to configure any parameter that can be changed.Table 4 lists the configuration parameters for the thermocouple inputs.
Table 4
Thermocouple Input Configuration parameters    
Description    Default Value    Range    
Input #n – Suspect Parameter Number (SPN)     0     Any SPN listed in Table 3    
Input #n - Type     Not Installed     Not Installed
Type-J
Type-K    
Input #n – High Temperature Shutdown Threshold     95 °C (203 °F)    
0 °C (32 °F) to
1735 °C (3155 °F)    
Input #n – High Temperature Warning Threshold    
85 °C (185 °F)    
0 °C (32 °F) to
1735 °C (3155 °F)    
Input #n – Low Temperature Warning Threshold    
-200 °C (-328 °F)    
-200 °C (-328 °F) to
800 °C (1472 °F)    
Input #n – High Temperature Shutdown Delay Time     1     0 to 120 seconds    
Input #n – High Temperature Warning Delay Time     1     0 to 120 seconds    
Input #n – Low Temperature Warning Delay Time     1     0 to 120 seconds    Specifications
Table 5 lists the specifications for the thermocouple module.
Table 5
Thermocouple Module Specifications    
Valid Thermocouple Types     Type-J and Type-K    
Operating Voltage Range     9 VDC to 32 VDC    
Nominal Voltage Range     12 VDC or 24 VDC    
Overvoltage Capability     32 VDC for 1 hour at
85 °C (185 °F)    
Ambient Storage Temperature    
-50 °C (-58 °F) to
125 °C (257 °F)    
Ambient Operating Temperature Range    
-40 °C (-40 °F) to
120 °C (248 °F)
(see notes)    Note: If the ambient temperature exceeds 85 °C (185 °F), then the thermocouple module may deviate in accuracy +/- 1° C.Note: If the ambient temperature exceeds 120 °C (248 °F), then the thermocouple module may not return to proper operation.
The thermocouple module will remain fully functional during single set point configuration and also during communications on the data link.
Even if the communication link is terminated, the thermocouple module will continue to operate normally.
All configured values and error codes are stored in non-volatile memory. Non-volatile memory allows retention of all parameter values and error codes when the thermocouple module is de-energized.
The thermocouple module is configured on the secondary data link (CAN2). Configuration is accomplished by using the Cat Service Tool to configure any parameter that can be changed.Table 4 lists the configuration parameters for the thermocouple inputs.
Table 4
Thermocouple Input Configuration parameters    
Description    Default Value    Range    
Input #n – Suspect Parameter Number (SPN)     0     Any SPN listed in Table 3    
Input #n - Type     Not Installed     Not Installed
Type-J
Type-K    
Input #n – High Temperature Shutdown Threshold     95 °C (203 °F)    
0 °C (32 °F) to
1735 °C (3155 °F)    
Input #n – High Temperature Warning Threshold    
85 °C (185 °F)    
0 °C (32 °F) to
1735 °C (3155 °F)    
Input #n – Low Temperature Warning Threshold    
-200 °C (-328 °F)    
-200 °C (-328 °F) to
800 °C (1472 °F)    
Input #n – High Temperature Shutdown Delay Time     1     0 to 120 seconds    
Input #n – High Temperature Warning Delay Time     1     0 to 120 seconds    
Input #n – Low Temperature Warning Delay Time     1     0 to 120 seconds    Specifications
Table 5 lists the specifications for the thermocouple module.
Table 5
Thermocouple Module Specifications    
Valid Thermocouple Types     Type-J and Type-K    
Operating Voltage Range     9 VDC to 32 VDC    
Nominal Voltage Range     12 VDC or 24 VDC    
Overvoltage Capability     32 VDC for 1 hour at
85 °C (185 °F)    
Ambient Storage Temperature    
-50 °C (-58 °F) to
125 °C (257 °F)    
Ambient Operating Temperature Range    
-40 °C (-40 °F) to
120 °C (248 °F)
(see notes)    Note: If the ambient temperature exceeds 85 °C (185 °F), then the thermocouple module may deviate in accuracy +/- 1° C.Note: If the ambient temperature exceeds 120 °C (248 °F), then the thermocouple module may not return to proper operation.
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts window Caterpillar catalog:
2434430
WINDOW GP-CAB
420D, 420E
420D, 420E
1557061
WINDOW AR-POWER
325B, 325B L, 330B, 345B II
325B, 325B L, 330B, 345B II
1557043
WINDOW GP-FRONT
311B, 312B, 315B, 318B, 320B, 320B U, 322B, 322B L, 325B, 325B L, 330B, 330B L, 345B, 345B II, 345B L
311B, 312B, 315B, 318B, 320B, 320B U, 322B, 322B L, 325B, 325B L, 330B, 330B L, 345B, 345B II, 345B L
3531978
WINDOW AR-CAB
308D, 314D CR, 314D LCR, 321D LCR
308D, 314D CR, 314D LCR, 321D LCR
3858753
WINDOW GP-CAB
D6R, D6R STD, D7R XR
D6R, D6R STD, D7R XR
1662103
WINDOW GP-CAB
D5N, D5R LGP, D6N, D6N LGP
D5N, D5R LGP, D6N, D6N LGP
3132072
WINDOW GP-CAB
583T, 587T, PL83, PL87
583T, 587T, PL83, PL87
3923980
WINDOW GP-DOOR
950 GC
950 GC
8I1777
WINDOW GP-CAB
611, 613C II, 615C
611, 613C II, 615C
2583285
WINDOW GP-CAB
246C, 256C, 262C, 262C2, 272C, 272D, 272D XHP, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 299D, 299D XHP
246C, 256C, 262C, 262C2, 272C, 272D, 272D XHP, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 299D, 299D XHP