1383066 WIRE AS Caterpillar parts
Rating:
Alternative (cross code) number:
CA1383066
138-3066
1383066
CA1383066
138-3066
1383066
Weight: 0.90 pounds 0 kg.
Information:
Specification
Table 1
"Travel on Level Ground - Test"
Travel Time (time in seconds)
Machine Travel Speed New Service Limit Actual
336 GC HIGH Forward 21.7 1.0 28.2 1.0
Reverse
LOW Forward 33.3 1.0 43.3 1.0
Reverse
336 HIGH Forward 23.8 1.0 30.9 1.0
Reverse
LOW Forward 36.3 1.0 47.2 1.0
Reverse
Travel Deviation(1) mm (inch)
Travel Speed New Service Limit Actual
HIGH Forward 650 mm (25.6 inch) or less 650 mm (25.6 inch) or less
Reverse
LOW Forward 650 mm (25.6 inch) or less 650 mm (25.6 inch) or less
Reverse
(1) Travel deviation (distance) from the reference lineIntroduction
The performance level of the travel motors can be determined with the following procedure.Note: The engine speed and/or the machine configuration that is used during this test can affect the results of this test. Refer to Testing and Adjusting, "Engine Performance - Test (Engine Speed)" for the engine speed that was used for this test. Refer to Testing and Adjusting, "Operational Checks" for the machine configurations that were used for this test.Note: The relief valve pressure settings must be set to the relief valve pressure specification before performing this operational check. Refer to Testing and Adjusting, "Specifications".Required Tools
Table 2
Description Qty
Measuring Tape 1
Stopwatch 1 Machine Preparation
Illustration 1 g06248651
(A) Preliminary run 5 m (16.4 ft)
(B) Travel distance 20 m (65.6 ft)
(C) Bucket height 0.5 to 1 m (1.6 to 3.3 ft)
Travel distance must be at least 25 m (82 ft) long. Travel test ground must be hard and as level as possible.
Draw a 25 m (82 ft) straight line on travel test ground as a reference line.Test Procedure
Start the engine.
Place the machine controls at the following settings: Engine speed dial "7" and AEC switch OFF.
Increase the hydraulic oil temperature to 55° 5°C (131° 9°F).
The bucket should be empty.
Position the machine so that one track is parallel with the reference line. Position the machine for the travel test. Refer to Illustration 1.
Place the travel speed control switch in HIGH position.
Move the machine by operating both travel levers at the same time.
The first 5 m (16.4 ft) are for a preliminary run. Measure the travel time that is required to travel the remaining 20 m (65.6 ft). Measure the time that is required in each direction.
Measure the travel deviation from the reference line.
Place the travel speed control switch on the LOW position and repeat Steps 7 through 9.
Table 1
"Travel on Level Ground - Test"
Travel Time (time in seconds)
Machine Travel Speed New Service Limit Actual
336 GC HIGH Forward 21.7 1.0 28.2 1.0
Reverse
LOW Forward 33.3 1.0 43.3 1.0
Reverse
336 HIGH Forward 23.8 1.0 30.9 1.0
Reverse
LOW Forward 36.3 1.0 47.2 1.0
Reverse
Travel Deviation(1) mm (inch)
Travel Speed New Service Limit Actual
HIGH Forward 650 mm (25.6 inch) or less 650 mm (25.6 inch) or less
Reverse
LOW Forward 650 mm (25.6 inch) or less 650 mm (25.6 inch) or less
Reverse
(1) Travel deviation (distance) from the reference lineIntroduction
The performance level of the travel motors can be determined with the following procedure.Note: The engine speed and/or the machine configuration that is used during this test can affect the results of this test. Refer to Testing and Adjusting, "Engine Performance - Test (Engine Speed)" for the engine speed that was used for this test. Refer to Testing and Adjusting, "Operational Checks" for the machine configurations that were used for this test.Note: The relief valve pressure settings must be set to the relief valve pressure specification before performing this operational check. Refer to Testing and Adjusting, "Specifications".Required Tools
Table 2
Description Qty
Measuring Tape 1
Stopwatch 1 Machine Preparation
Illustration 1 g06248651
(A) Preliminary run 5 m (16.4 ft)
(B) Travel distance 20 m (65.6 ft)
(C) Bucket height 0.5 to 1 m (1.6 to 3.3 ft)
Travel distance must be at least 25 m (82 ft) long. Travel test ground must be hard and as level as possible.
Draw a 25 m (82 ft) straight line on travel test ground as a reference line.Test Procedure
Start the engine.
Place the machine controls at the following settings: Engine speed dial "7" and AEC switch OFF.
Increase the hydraulic oil temperature to 55° 5°C (131° 9°F).
The bucket should be empty.
Position the machine so that one track is parallel with the reference line. Position the machine for the travel test. Refer to Illustration 1.
Place the travel speed control switch in HIGH position.
Move the machine by operating both travel levers at the same time.
The first 5 m (16.4 ft) are for a preliminary run. Measure the travel time that is required to travel the remaining 20 m (65.6 ft). Measure the time that is required in each direction.
Measure the travel deviation from the reference line.
Place the travel speed control switch on the LOW position and repeat Steps 7 through 9.
Parts wire Caterpillar catalog:
1383060
WIRE AS
Caterpillar
Caterpillar
1383058
WIRE AS
Caterpillar
Caterpillar
1383052
WIRE AS
Caterpillar
Caterpillar
1377800
WIRE AS.
Caterpillar
Caterpillar
1376155
WIRE
Caterpillar
Caterpillar
1376134
WIRE
Caterpillar
Caterpillar
1383068
WIRE AS
Caterpillar
Caterpillar
1388582
WIRE AS (EHC)
Caterpillar
Caterpillar
1395356
WIRE AS.
Caterpillar
Caterpillar
1395358
WIRE AS.
Caterpillar
Caterpillar
1396034
WIRE AS
Caterpillar
Caterpillar
1413201
WIRE
Caterpillar
Caterpillar