2062786 WIRING GP-CONSOLE Caterpillar parts
385B
Rating:
Alternative (cross code) number:
CA2062786
206-2786
2062786
CA2062786
206-2786
2062786
EXCAVATOR,
Compatible equipment models: 2062786:
Information:
Illustration 1 g00627903
Schematic of the blade control handleThis diagnostic code is recorded when the implement ECM reads the signal from the trigger switch (pitch forward) as being incorrect. The signal that is being received by the ECM is changing at a faster rate or a slower rate than the ECM expected. The rate of change is outside the expected limits. However, this value is not outside the maximum value or the minimum value.The possible causes of this diagnostic code are listed:
The switch has failed.
An intermittent open in the circuit
An intermittent short in the circuit
The ECM has failed. This is unlikely.Note: Ensure that CID 0876 FMI 10 is active. The following procedure can cause new diagnostic codes to be recorded. Ignore these created diagnostic codes. When the procedure is completed, clear the created diagnostic codes.Test Step 1. CHECK FOR AN OPEN CIRCUIT.
Turn the disconnect switch and the key start switch to the OFF position.
Disconnect the
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts wiring Caterpillar catalog:
2076753
WIRING GP-PLATFORM
385B, 5090B
385B, 5090B
2345738
WIRING GP-BOOM
385B, 385C L
385B, 385C L
2291429
WIRING GP-MATERIAL HANDLER
330C, 330C L
330C, 330C L
1933391
WIRING GP-FINE SWING
330C, 330C L
330C, 330C L
2422992
WIRING GP-WORK TOOL
325C, 330C L
325C, 330C L
2640215
WIRING GP-QUICK COUPLER
322C, 325C, 325D L
322C, 325C, 325D L
2463109
WIRING GP-CONSOLE
365B II, 385B
365B II, 385B
2461414
WIRING GP-CONSOLE
365B II, 385B
365B II, 385B
2076755
WIRING GP-CONSOLE
365B, 385B, 5090B
365B, 385B, 5090B