AVSPARE.COM
parts catalog

WIRING GP-ELECTRONIC CONTROL 2292921 - Caterpillar


2292921 WIRING GP-ELECTRONIC CONTROL Caterpillar parts C11, C13
Rating:
54
Alternative (cross code) number:
CA2292921
229-2921
2292921
Caterpillar 2292921 WIRING GP-ELECTRONIC CONTROL

Buy WIRING GP-ELECTRONIC CONTROL 2292921 Caterpillar genuine, new aftermarket tractor parts with delivery
TRUCK ENGINE,

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
$82.56

23 Mar 2025
0.1102[0.05] Pounds
CN: bbo99l
MJUYHT 219-2372 Fuel Injector Nozzle Repair Common Rail Injector 235-2888 229-2921 C-9-001
MJUYHT The atomizing nozzle can effectively and evenly spray spray || Multiple types of fuel injectors are available for selection || Reduce fuel consumption by precise control of fuel injection quantity || Power output and fuel economy of the engine || The appearance fits directly, promoting smooth operation of the engine
Number on catalog scheme:
  For full view, you need register

Compatible equipment models: 2292921:

TRUCK ENGINE  C11   C13   Caterpillar

Information:


Illustration 1 g00880157
Test Step 1. Inspect Electrical Connectors and Wiring
Turn the keyswitch to the OFF/RESET position.
Thoroughly inspect the J1/P1 ECM connector, the J3/P3 machine connector, and all other connectors in the wiring harness. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.Expected Result:All connectors, pins, and sockets should be completely inserted and coupled. The harness and wiring should be free of corrosion, abrasion, and pinch points. All connections and grounds should be tight and free of corrosion.Results:
OK - Proceed to Test Step 2.
Not OK - Repair: Repair the circuit.Verify that the repair eliminates the problem.STOPTest Step 2. Check the Resistance through the Solenoid
Turn the keyswitch to the OFF/RESET position.
Disconnect the push/pull solenoid for the variable pitch fan.
Measure the resistance between J160:1 (Push Solenoid) and J160:2 (Digital Return).
Measure the resistance between J160:4 (Pull Solenoid) and J160:3 (Digital Return).Expected Result:Resistance should be 25 5 Ohms.Results:
OK - The push/pull solenoid for the variable pitch fan has the correct resistance. Proceed to Test Step 3.
Not OK - The push/pull solenoid for the variable pitch fan is faulty.Repair: Install a new push/pull solenoid for the variable pitch fan.Verify that the repair eliminates the problem.STOPTest Step 3. Check the Status of the Manual Purge Switch onCaterpillar Electronic Technician (Cat ET)
Connect Cat ET to the service tool connector.
Turn the keyswitch to the ON position.
Observe the status for "Engine Fan Manual Purge Switch" on Cat ET while you operate the switch.
Turn the keyswitch to the OFF/RESET position.Expected Result:The status of the switch should be "On" when the switch is depressed. The status should read "Off" when the switch is released.Results:
OK - The manual purge switch is working properly. Proceed to Test Step 5.
Not OK - The ECM does not recognize the input from the manual purge switch. Proceed to Test Step 4.Test Step 4. Check the Manual Purge Switch
Turn the keyswitch to the OFF/RESET position.
Disconnect the J161/P161 manual purge switch connector.
Measure continuity between P161:A (Manual Purge Switch) and P161:B (Digital Return) with the manual purge switch in the released position.
Measure continuity between P161:A (Manual Purge Switch) and P161:B (Digital Return) with the manual purge switch in the depressed position.Expected Result:There should be no continuity between P161:A (Manual Purge Switch) and P161:B (Digital Return) when the switch is in the released position. There should be continuity between P161:A (Manual Purge Switch) and P161:B (Digital Return) when the switch is in the depressed position.Results:
OK - There is no continuity when the switch is in the released position. There is continuity when the switch is in the depressed position. Proceed to Test Step 5.
Not OK - There is a problem with the manual purge switch.Repair: Replace the manual purge switch with a new switch.Verify that the repair eliminates the problem.STOPTest Step 5. Check for Shorts in the Harness for the Variable Pitch Fan
Illustration 2 g00880165
Disconnect the J1/P1 ECM connector.
Disconnect the J160/P160 push/pull solenoid connector.
Disconnect the J161/P161 manual purge switch connector.
Measure the resistance between P1:45 (Manual Purge Switch) and chassis ground.
Measure the resistance between P1:13 (Pull Solenoid) and chassis ground.
Measure the

Cat SIS web machinery list:

Caterpillar parts catalog
C11 On-highway Truck Engine KCA00001-UP


Parts wiring Caterpillar catalog:

2574183 WIRING GP-UNIT INJECTOR
143H, 14M, 16H, 16M, 3126E, 3176, 3176B, 3176C, 3196, 3406E, 3408E, 3412C, 3412E, 3456, 345C, 345C MH, 572R II, 583T, 621G, 623G, 627G, 631G, 637G, 657G, 725, 730, 735, 740, 769D, 770, 772, 773D, 773E...
3079166 WIRING GP-HEATER
AP-600D, AP-655D, AS4251C
2677643 WIRING GP-QUICK COUPLER
324D, 324D LN, 325D, 325D L, 329D L
Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.