Information:
Electrical shock hazard. The electronic unit injector system uses 90-120 volts.
Remove electrical power from the ECM.
Disconnect the connectors for the valve cover at the valve cover base.
Fabricate a jumper wire that will be long enough to short circuit the different terminal connector locations at the valve cover. Crimp connector pins on both ends of the jumper wire.
Insert one end of the jumper wire into the connector socket at the valve cover for the suspect injector's supply wire. Insert the other end of the jumper wire into the connector socket at the valve cover for the suspect injector's return wire. This will replace the injector solenoid with a short circuit.
Restore electrical power to the ECM.
Perform the "Injector Solenoid Test" at least two times.
Repeat this test for each suspect circuit. Stop the "Injector Solenoid Test" before handling the jumper wire. Restore the wiring to the original configuration.Expected Result:Cat ET displays "Short" for each of the circuits that were jumpered.Results:
OK - Cat ET displays "Short" for each circuit that was jumpered. The harness between the ECM and the valve cover connectors does not have an open circuit. Proceed to Test Step 7.
Not OK - Cat ET displays "Open" for the cylinder with the jumper wire. There is a problem in the wiring between the ECM and the valve cover connectors. Proceed to Test Step 8.Test Step 6. Check the Harness between the ECM and the Valve Cover Base for a Short Circuit
Electrical shock hazard. The electronic unit injector system uses 90-120 volts.
Remove electrical power from the ECM.
Disconnect the valve cover connectors.
Restore electrical power to the ECM.
Perform the "Injector Solenoid Test" at least two times.Expected Result:All of the cylinders indicate "Open" on Cat ET.Results:
OK - All cylinders indicate "Open" on Cat ET. The harness between the ECM and the valve cover connectors does not have a short circuit. Proceed to Test Step 7.
Not OK - One or more cylinders indicate "Short" on Cat ET. Note the cylinders that indicate "Short". Proceed to Test Step 8.Test Step 7. Check the Injector Harness Under the Valve Cover for an Open Circuit or for a Short Circuit
Electrical shock hazard. The electronic unit injector system uses 90-120 volts.
Remove electrical power from the ECM.
Remove the valve cover in order to gain access to the suspect injector.
Disconnect the harness connector from the suspect injector.
Thoroughly clean the terminals on the injector solenoid and on the harness connector.
Use a jumper wire to short circuit the connector terminals for the suspect injector. This will effectively replace the injector solenoid with a short circuit.
Restore electrical power to the ECM.
Perform the "Injector Solenoid Test" at least two times.Note: The injector solenoid that shares the return wire of the injector that is short circuited may indicate a false test result. Disregard this test result.
Remove electrical power from the ECM.
Remove the jumper wire from the injector connector. This will effectively replace the injector solenoid with an open circuit.
Restore electrical power to the ECM.
Perform the "Injector Solenoid Test" at least two times.
Remove electrical power from the
Parts wrench Caterpillar catalog:
2147317
WRENCH-
Caterpillar
Caterpillar
2147315
WRENCH-
Caterpillar
Caterpillar
2147314
WRENCH-
Caterpillar
Caterpillar
2147222
WRENCH-32MM
Caterpillar
Caterpillar
2147220
WRENCH-29MM
Caterpillar
Caterpillar
2147218
WRENCH-27 MM
Caterpillar
Caterpillar
2223048
WRENCH-IMPACT
Caterpillar
Caterpillar
2208430
WRENCH-PINION
Caterpillar
Caterpillar
2208428
WRENCH-SPANNER
Caterpillar
Caterpillar
2190476
WRENCH-SPANNER
Caterpillar
Caterpillar
2147349
WRENCH-TORQUE
Caterpillar
Caterpillar
2147335
WRENCH SET
Caterpillar
Caterpillar