1343032 YOKE AS Caterpillar parts
966G, 966G II, 966H, 966K, 972G, 972G II, 972H, 972K, IT38G II
Rating:
Alternative (cross code) number:
CA1343032
134-3032
1343032
CA1343032
134-3032
1343032
Weight: 17 pounds 7 kg.
INTEGRATED TOOLCARRIER, WHEEL LOADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 1343032:
Information:
Woodward Governors are usually electrically operated from a control panel.Starting The Engine
Woodward PSG Governor
1. Perform all pre-start checks outlined previously. In addition, be sure the alternator and alternator belt are properly installed and adjusted. On some installations, low alternator output frequency will operate a relay to stop the starter. The alternator belts on these arrangements must be inspected regularly for proper belt tension and condition. 2. Push the ON-OFF-STOP switch to the ON position. 3. When the engine starts, move the switch to the OFF position. 4. Start the load.5. Regulate the engine speed with the RAISE-LOWER switch to attain the required instrument panel gauge readings. Woodward UG8 Governor
Start the engine as follows:1. Perform all pre-start checks outlined previously.2. Check the oil level in the sight level gauge with the engine stopped. Oil level should be near the top of the sight level gauge. See the LUBRICATION AND MAINTENANCE PROCEDURES. 3. Turn the load limit knob (3) until the indicator is between "5" and "7".4. Turn the synchronizer knob (2) clockwise until the indicator (4) is at "8". If the governor is equipped with an electric motor, operate synchronizer knob (2) by using the RAISE-LOWER switch on the control panel.5. Move the START-STOP switch to the START position; start the engine.6. Run the engine at low idle for 5 minutes.7. Turn the load limit knob (3) to "10".8. Turn synchronizing knob (2) clockwise until the engine runs at full governed speed.9. Turn speed droop knob (1) to obtain proper droop for the operation: a. For single unit operation, set knob (1) at "0".b. For parallel operation: See Parallel Operation Droop Adjustment in the ELECTRIC SET OPERATION instructions. Speed droop knob (1) on the first unit on the line may be set at "0" droop, and the remaining units set between "30" and "70". These settings should provide constant speed or frequency. If constant speed is not required, set droop knob (1) on all units between "30" and "70".10. Apply the load and readjust the synchronizer knob (2) to obtain the desired load division. Load pointer (5) indicates the relative load.Stopping The Engine
1. Remove the load. See ELECTRIC SET OPERATION instructions if equipped with an electric set generator.2. Reduce engine speed to low idle: Push down and hold the RAISE-LOWER switch until the engine low idle speed is reached. When manually operating a UG8 Governor, move the synchronizer knob until the synchronizer indicator points to "8", or the low idle stop is reached.3. While the engine is idling, check the engine oil level. Oil level must be maintained between the ADD and FULL mark on the side of the dipstick marked CHECK WITH ENGINE RUNNING.4. Stop the engine. a. Solenoid Shutoff: Move the ON-OFF-STOP switch to the STOP position. Hold the switch until the engine stops. b. PSG Governor: Move the shutoff lever forward, or hold the lever up, depending upon installation. Hold the lever in this position until the engine stops. c. UG8 Governor: Turn the load limit
Woodward PSG Governor
1. Perform all pre-start checks outlined previously. In addition, be sure the alternator and alternator belt are properly installed and adjusted. On some installations, low alternator output frequency will operate a relay to stop the starter. The alternator belts on these arrangements must be inspected regularly for proper belt tension and condition. 2. Push the ON-OFF-STOP switch to the ON position. 3. When the engine starts, move the switch to the OFF position. 4. Start the load.5. Regulate the engine speed with the RAISE-LOWER switch to attain the required instrument panel gauge readings. Woodward UG8 Governor
Start the engine as follows:1. Perform all pre-start checks outlined previously.2. Check the oil level in the sight level gauge with the engine stopped. Oil level should be near the top of the sight level gauge. See the LUBRICATION AND MAINTENANCE PROCEDURES. 3. Turn the load limit knob (3) until the indicator is between "5" and "7".4. Turn the synchronizer knob (2) clockwise until the indicator (4) is at "8". If the governor is equipped with an electric motor, operate synchronizer knob (2) by using the RAISE-LOWER switch on the control panel.5. Move the START-STOP switch to the START position; start the engine.6. Run the engine at low idle for 5 minutes.7. Turn the load limit knob (3) to "10".8. Turn synchronizing knob (2) clockwise until the engine runs at full governed speed.9. Turn speed droop knob (1) to obtain proper droop for the operation: a. For single unit operation, set knob (1) at "0".b. For parallel operation: See Parallel Operation Droop Adjustment in the ELECTRIC SET OPERATION instructions. Speed droop knob (1) on the first unit on the line may be set at "0" droop, and the remaining units set between "30" and "70". These settings should provide constant speed or frequency. If constant speed is not required, set droop knob (1) on all units between "30" and "70".10. Apply the load and readjust the synchronizer knob (2) to obtain the desired load division. Load pointer (5) indicates the relative load.Stopping The Engine
1. Remove the load. See ELECTRIC SET OPERATION instructions if equipped with an electric set generator.2. Reduce engine speed to low idle: Push down and hold the RAISE-LOWER switch until the engine low idle speed is reached. When manually operating a UG8 Governor, move the synchronizer knob until the synchronizer indicator points to "8", or the low idle stop is reached.3. While the engine is idling, check the engine oil level. Oil level must be maintained between the ADD and FULL mark on the side of the dipstick marked CHECK WITH ENGINE RUNNING.4. Stop the engine. a. Solenoid Shutoff: Move the ON-OFF-STOP switch to the STOP position. Hold the switch until the engine stops. b. PSG Governor: Move the shutoff lever forward, or hold the lever up, depending upon installation. Hold the lever in this position until the engine stops. c. UG8 Governor: Turn the load limit
Caterpillar parts catalog:
Parts yoke Caterpillar catalog:
1666762
YOKE-BRAKE
938G, 938G II, 938H, IT38G, IT38G II, IT38H
938G, 938G II, 938H, IT38G, IT38G II, IT38H
8E4950
YOKE
928F, 938G, 938G II, IT28F, IT38G, IT38G II
928F, 938G, 938G II, IT28F, IT38G, IT38G II
1666757
YOKE
938G, 938G II, IT38G, IT38G II
938G, 938G II, IT38G, IT38G II
1591846
YOKE AS
938G, 938G II, IT38G, IT38G II
938G, 938G II, IT38G, IT38G II
1666760
YOKE
938G, 938G II, 938H, 938K, IT38G, IT38G II, IT38H
938G, 938G II, 938H, 938K, IT38G, IT38G II, IT38H
1174465
YOKE AS
966G, 966G II, 966H, 966K, 966M, 966M XE, 972G, 972G II, 972H, 972K, 972M, 972M XE
966G, 966G II, 966H, 966K, 966M, 966M XE, 972G, 972G II, 972H, 972K, 972M, 972M XE
1561150
YOKE AS
966G, 966G II, 966H, 966K, 966M, 966M XE, 972G, 972G II, 972H, 972K, 972M, 972M XE
966G, 966G II, 966H, 966K, 966M, 966M XE, 972G, 972G II, 972H, 972K, 972M, 972M XE
1793185
YOKE-BRAKE
966G, 966G II, 966H, 972G, 972G II, 972H
966G, 966G II, 966H, 972G, 972G II, 972H
3679654
YOKE-BRAKE
966K, 972K
966K, 972K
1258801
YOKE
966G
966G
1911831
YOKE
950G, 950G II, 950H, 950K, 962G, 962G II, 962H, 962K, IT62G II, IT62H
950G, 950G II, 950H, 950K, 962G, 962G II, 962H, 962K, IT62G II, IT62H
1381736
YOKE AS
924G, 924GZ, 924H, 924HZ
924G, 924GZ, 924H, 924HZ
2217117
YOKE AS
924G, 924GZ, 924H, 924HZ
924G, 924GZ, 924H, 924HZ
1555606
YOKE
950G, 950G II, 950H, 950K, 962G, 962G II, 962H, 962K, 966M, 966M XE, 972M, 972M XE, IT62G, IT62G II, IT62H
950G, 950G II, 950H, 950K, 962G, 962G II, 962H, 962K, 966M, 966M XE, 972M, 972M XE, IT62G, IT62G II, IT62H
1555608
YOKE-BRAKE
950G, 950G II, 962G, 962G II, IT62G, IT62G II
950G, 950G II, 962G, 962G II, IT62G, IT62G II
1555602
YOKE
950G, 950G II, 950H, 950K, 962G, 962G II, 962H, 962K, IT62G, IT62G II, IT62H
950G, 950G II, 950H, 950K, 962G, 962G II, 962H, 962K, IT62G, IT62G II, IT62H
2925388
YOKE-END
906H, 906H2, 907H, 907H2, 908H, 908H2
906H, 906H2, 907H, 907H2, 908H, 908H2
9D9100
YOKE AS
641B, 657G
641B, 657G
2547125
YOKE
904B
904B
2706303
YOKE AS
904B, 904H
904B, 904H
2032764
YOKE AS
924H, 924HZ, 928H, 928HZ, 930G, IT28G
924H, 924HZ, 928H, 928HZ, 930G, IT28G
2032759
YOKE AS
924K, 928H, 928HZ, 930G, 930K, IT28G
924K, 928H, 928HZ, 930G, 930K, IT28G