3086005 YOKE AS Caterpillar parts
735, 735B, 740, 740B
Rating:
Alternative (cross code) number:
CA3086005
308-6005
3086005
CA3086005
308-6005
3086005
Weight: 25 pounds 11 kg.
ARTICULATED TRUCK, EJECTOR TRUCK,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$26.07
15 Oct 2022
0.34[0.15] Pounds
Amazon.com
Bargman 3086005 Red Wrap-Around Light
Bargman Product Type: Auto Accessory || Package Quantity: 1 || Package Dimensions: 6.8" (L) x 3.8" (W) x 1.8" (H) || Package Weight: 7.25
Bargman Product Type: Auto Accessory || Package Quantity: 1 || Package Dimensions: 6.8" (L) x 3.8" (W) x 1.8" (H) || Package Weight: 7.25
$25.05
02 Sep 2022
0.34[0.15] Pounds
Amazon.com
Bargman 3086005 Red Wrap-Around Light
Bargman Product Type: Auto Accessory || Package Quantity: 1 || Package Dimensions: 6.8" (L) x 3.8" (W) x 1.8" (H) || Package Weight: 7.25
Bargman Product Type: Auto Accessory || Package Quantity: 1 || Package Dimensions: 6.8" (L) x 3.8" (W) x 1.8" (H) || Package Weight: 7.25
Compatible equipment models: 3086005:
Information:
Required Tools
Illustration 1 g01623868
Tooling group "B"
198-4240 Digital Pressure Indicator Gp
Table 1
Tool Item Part Number Description Qty
B 198-4240 Digital Pressure Indicator Gp
B1 198-4234 Indicator 1
B2 198-4237 Pressure Sensor 3445 kPa (500 psi) 2
B3 198-4236 Extension Cable 2 Machine Preparation
The following procedures must be completed before performing the calibration.
Set the pilot pressure to the specifications in Testing and Adjusting, "Relief Valve (Pilot) - Test and Adjust" for the machine.
Calibrate the power shift pressure. Refer to Testing and Adjusting, "Solenoid Valve (Proportional Reducing) - Calibrate (Power Shift Pressure)" for the machine.
Position the machine on level ground and stop the engine.
Release the pressure in the hydraulic system. Refer to Testing and Adjusting, "System Pressure - Release".
Illustration 2 g02352540
Pressure taps for the proportional reducing valves (negative flow control)
(1) Pressure tap for "NFC1"
(2) Pressure tap for "NFC2"
Connect two 3445 kPa (500 psi) pressure sensors to the pressure taps on the proportional reducing valves for negative flow control. The proportional reducing valve pressure taps for negative flow control of the drive pump and idler pump are located in the pump compartment.
Start the engine.
Increase the hydraulic oil temperature to 55° 5°C (131° 9°F).
Place the hydraulic activation lever in the UNLOCK position. Calibration Procedure
Note: This procedure is typical for both proportional reducing valves for negative flow control.
Enter the service mode. Input the password "9992".
Illustration 3 g02540004
Select "Main Pump Flow Limit" from the "Calibrations" menu.
Illustration 4 g02540097
Select "NFC (Press Gauge Method)" for the appropriate valve from the "Main Pump Flow Limit" menu.
Press the OK key in order to start the calibration. The engine RPM will automatically increase to the equivalence of engine speed dial 10.
Confirm the notes on the monitor display. Set up the test conditions in accordance with the instructions. Press the OK key.
Move the joystick for STICK OUT to the full out position and hold the joystick in this position. Note: If necessary, a BOOM RAISE function may be performed in place of STICK OUT.
Illustration 5 g02540199
Use the arrows to adjust the pressure until the pressure reading for the negative flow control valve is at 1500 50 kPa (218 7 psi). Press the OK key. Note: Use the arrows to scroll down to view the machine "Engine Speed", "Hydraulic Oil Temperature", "Pump #1 Outlet Pressure", and "Pump #2 Outlet Pressure".
Move the joystick for STICK OUT to the NEUTRAL position.
Confirm notes on the monitor display. Set up the test conditions in accordance with the instructions. Press the OK key.
Move the joystick for STICK OUT to the full out position and hold the joystick in this position. Note: If necessary, a BOOM RAISE function may be performed in place of STICK OUT.
Illustration 6 g02540267
Use the arrows to adjust the pressure until the pressure reading for the negative flow control valve is at 3000 50 kPa (435 7 psi). Press the OK key. Note: Use the arrows to scroll down to view the machine "Engine Speed", "Hydraulic Oil Temperature", "Pump #1 Outlet Pressure", and "Pump #2 Outlet Pressure".
Move the joystick for STICK OUT to the
Illustration 1 g01623868
Tooling group "B"
198-4240 Digital Pressure Indicator Gp
Table 1
Tool Item Part Number Description Qty
B 198-4240 Digital Pressure Indicator Gp
B1 198-4234 Indicator 1
B2 198-4237 Pressure Sensor 3445 kPa (500 psi) 2
B3 198-4236 Extension Cable 2 Machine Preparation
The following procedures must be completed before performing the calibration.
Set the pilot pressure to the specifications in Testing and Adjusting, "Relief Valve (Pilot) - Test and Adjust" for the machine.
Calibrate the power shift pressure. Refer to Testing and Adjusting, "Solenoid Valve (Proportional Reducing) - Calibrate (Power Shift Pressure)" for the machine.
Position the machine on level ground and stop the engine.
Release the pressure in the hydraulic system. Refer to Testing and Adjusting, "System Pressure - Release".
Illustration 2 g02352540
Pressure taps for the proportional reducing valves (negative flow control)
(1) Pressure tap for "NFC1"
(2) Pressure tap for "NFC2"
Connect two 3445 kPa (500 psi) pressure sensors to the pressure taps on the proportional reducing valves for negative flow control. The proportional reducing valve pressure taps for negative flow control of the drive pump and idler pump are located in the pump compartment.
Start the engine.
Increase the hydraulic oil temperature to 55° 5°C (131° 9°F).
Place the hydraulic activation lever in the UNLOCK position. Calibration Procedure
Note: This procedure is typical for both proportional reducing valves for negative flow control.
Enter the service mode. Input the password "9992".
Illustration 3 g02540004
Select "Main Pump Flow Limit" from the "Calibrations" menu.
Illustration 4 g02540097
Select "NFC (Press Gauge Method)" for the appropriate valve from the "Main Pump Flow Limit" menu.
Press the OK key in order to start the calibration. The engine RPM will automatically increase to the equivalence of engine speed dial 10.
Confirm the notes on the monitor display. Set up the test conditions in accordance with the instructions. Press the OK key.
Move the joystick for STICK OUT to the full out position and hold the joystick in this position. Note: If necessary, a BOOM RAISE function may be performed in place of STICK OUT.
Illustration 5 g02540199
Use the arrows to adjust the pressure until the pressure reading for the negative flow control valve is at 1500 50 kPa (218 7 psi). Press the OK key. Note: Use the arrows to scroll down to view the machine "Engine Speed", "Hydraulic Oil Temperature", "Pump #1 Outlet Pressure", and "Pump #2 Outlet Pressure".
Move the joystick for STICK OUT to the NEUTRAL position.
Confirm notes on the monitor display. Set up the test conditions in accordance with the instructions. Press the OK key.
Move the joystick for STICK OUT to the full out position and hold the joystick in this position. Note: If necessary, a BOOM RAISE function may be performed in place of STICK OUT.
Illustration 6 g02540267
Use the arrows to adjust the pressure until the pressure reading for the negative flow control valve is at 3000 50 kPa (435 7 psi). Press the OK key. Note: Use the arrows to scroll down to view the machine "Engine Speed", "Hydraulic Oil Temperature", "Pump #1 Outlet Pressure", and "Pump #2 Outlet Pressure".
Move the joystick for STICK OUT to the
Caterpillar parts catalog:
Parts yoke Caterpillar catalog:
1489398
YOKE AS
735, 740
735, 740
2108467
YOKE AS
735, 740
735, 740
2522101
YOKE AS
735, 740
735, 740
2279321
YOKE AS
735, 735B, 740, 740B
735, 735B, 740, 740B
1770841
YOKE AS
735, 735B, 740, 740B
735, 735B, 740, 740B
3086001
YOKE AS
735, 735B, 740, 740B
735, 735B, 740, 740B
3086000
YOKE AS
735, 735B, 740, 740B
735, 735B, 740, 740B
1489417
YOKE
735, 735B, 740, 740B
735, 735B, 740, 740B
1858766
YOKE AS
735, 735B, 740, 740B
735, 735B, 740, 740B
3085999
YOKE AS
735
735
3156194
YOKE AS
735B, 740B
735B, 740B
3156193
YOKE AS
735B, 740B
735B, 740B
3086001
YOKE AS
735, 735B, 740, 740B
735, 735B, 740, 740B
1770841
YOKE AS
735, 735B, 740, 740B
735, 735B, 740, 740B
2279321
YOKE AS
735, 735B, 740, 740B
735, 735B, 740, 740B
2522101
YOKE AS
735, 740
735, 740
2108467
YOKE AS
735, 740
735, 740
1489398
YOKE AS
735, 740
735, 740
1T2000
YOKE AS
24H, 773E, 775E
24H, 773E, 775E
3232171
YOKE AS
773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775E, 775F, 775G, 775G LRC, 775G OEM
773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775E, 775F, 775G, 775G LRC, 775G OEM
3232169
YOKE AS
769D, 770, 771D, 772, 772G, 772G OEM
769D, 770, 771D, 772, 772G, 772G OEM
1858766
YOKE AS
735, 735B, 740, 740B
735, 735B, 740, 740B
1489417
YOKE
735, 735B, 740, 740B
735, 735B, 740, 740B
3086000
YOKE AS
735, 735B, 740, 740B
735, 735B, 740, 740B