Implement ECM Event Code List
The following table lists the event codes that apply to the control system. The recommended response is listed. Use the Cat ET service tool to determine the event codes that are active or logged.
Table 3
Event Codes for the Implement ECM    
EID
(Level)    Description    Possible Cause and Recommended Response    
E861
(1)     Clock Manual Alignment Required     Go to synchronize hour meter function in ET to synchronize hour.    
E875
(1)     Low System Voltage     The system voltage is lower than 24.8 VDC.
Response: Check the battery and alternator for proper operation.    
E875
(2)     Low System Voltage     Event is active when the engine is running and system voltage is less than 24 VDC for more than 30 seconds.
Event is deactivated when the engine is running and system voltage is greater then 24.5 VDC for 3 seconds.
The alternator r-terminal is functioning while the engine is running.
Response: Check alternator for proper operation.
Response: Check the battery connections.    
E875
(3)     Low System Voltage     Event is active when the engine is running and system voltage is less than 23 VDC for more than 60 seconds.
Event is deactivated when the engine is running and system voltage is greater then 23.5 VDC for 3 seconds.
Response: IMMEDIATE SAFE SHUTDOWN REQUIRED.    
E876
(1)     High System Voltage     Event is active when the engine is running and system voltage exceeds 29.5 VDC.
Event is deactivated when the system voltage is less than 29.0 VDC for 2 seconds.
Response: IMMEDIATE SAFE SHUTDOWN REQUIRED.
Note: Refer to Special Instruction, REHS0354, "Charging System Troubleshooting".    
E876
(3)     High System Voltage     Event is active when the engine is running and system voltage exceeds 32 VDC.
Event is deactivated when the system voltage is less than 31.5 VDC for 2 seconds.
Response: IMMEDIATE SAFE SHUTDOWN REQUIRED.
Note: Refer to Special Instruction, REHS0354, "Charging System Troubleshooting".    
The following table lists the event codes that apply to the control system. The recommended response is listed. Use the Cat ET service tool to determine the event codes that are active or logged.
Table 3
Event Codes for the Implement ECM    
EID
(Level)    Description    Possible Cause and Recommended Response    
E861
(1)     Clock Manual Alignment Required     Go to synchronize hour meter function in ET to synchronize hour.    
E875
(1)     Low System Voltage     The system voltage is lower than 24.8 VDC.
Response: Check the battery and alternator for proper operation.    
E875
(2)     Low System Voltage     Event is active when the engine is running and system voltage is less than 24 VDC for more than 30 seconds.
Event is deactivated when the engine is running and system voltage is greater then 24.5 VDC for 3 seconds.
The alternator r-terminal is functioning while the engine is running.
Response: Check alternator for proper operation.
Response: Check the battery connections.    
E875
(3)     Low System Voltage     Event is active when the engine is running and system voltage is less than 23 VDC for more than 60 seconds.
Event is deactivated when the engine is running and system voltage is greater then 23.5 VDC for 3 seconds.
Response: IMMEDIATE SAFE SHUTDOWN REQUIRED.    
E876
(1)     High System Voltage     Event is active when the engine is running and system voltage exceeds 29.5 VDC.
Event is deactivated when the system voltage is less than 29.0 VDC for 2 seconds.
Response: IMMEDIATE SAFE SHUTDOWN REQUIRED.
Note: Refer to Special Instruction, REHS0354, "Charging System Troubleshooting".    
E876
(3)     High System Voltage     Event is active when the engine is running and system voltage exceeds 32 VDC.
Event is deactivated when the system voltage is less than 31.5 VDC for 2 seconds.
Response: IMMEDIATE SAFE SHUTDOWN REQUIRED.
Note: Refer to Special Instruction, REHS0354, "Charging System Troubleshooting".    
Parts yoke Caterpillar catalog:
7K7565
YOKE-END
216, 236, 815, 953C, 963, 963B, 963C, 973, 973C
216, 236, 815, 953C, 963, 963B, 963C, 973, 973C
3W8679
YOKE AS
973, 973C
973, 973C
7P9733
YOKE
943, 953, 953B, 963, 963B, 973
943, 953, 953B, 963, 963B, 973
8G9797
YOKE
973
973
4Y0365
YOKE ASSEM.
572G, 966F, 973, D4E
572G, 966F, 973, D4E
4Y0377
YOKE ASSEM.
920, 936, 936F, G936
920, 936, 936F, G936
4Y0365
YOKE ASSEM.
572G, 966F, 973, D4E
572G, 966F, 973, D4E
1186567
YOKE
527, D5H, D5M, D6H, D6M
527, D5H, D5M, D6H, D6M
4J6290
YOKE
127
127
5J0467
YOKE
119, 128
119, 128
8E4950
YOKE
928F, 938G, 938G II, IT28F, IT38G, IT38G II
928F, 938G, 938G II, IT28F, IT38G, IT38G II
1666762
YOKE-BRAKE
938G, 938G II, 938H, IT38G, IT38G II, IT38H
938G, 938G II, 938H, IT38G, IT38G II, IT38H
1591845
YOKE AS
938F, 938G, IT38F, IT38G
938F, 938G, IT38F, IT38G
1012857
YOKE
918F, 938G, 950G II, 962G II, 966G, 966G II, 972G, 972G II, IT18F, IT62G II
918F, 938G, 950G II, 962G II, 966G, 966G II, 972G, 972G II, IT18F, IT62G II
1271693
YOKE
938F, 938G, IT38F, IT38G
938F, 938G, IT38F, IT38G
4Y7623
YOKE
D7H, D7R
D7H, D7R