1695266 ENGINE AR-COMPLETE Caterpillar parts
C-10
Rating:
Alternative (cross code) number:
CA1695266
169-5266
1695266
CA1695266
169-5266
1695266
TRUCK ENGINE,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
The ROP Shop Genuine Simplicity Foam Poly Gasket fits 1695265 1695266 1695294 1695447 1696325
The ROP Shop
The ROP Shop
$54.15
09 Feb 2021
-: -
Simplicity Snapper Briggs 54" Mower Deck Engine PTO V-Belt (72.3") / 1734065SM, 1695266, 2690681, 2690792, 2691182
Genuine Simplicity PTO V-Belt (72.3") || Simplicity Part # 1734065SM || Replaces: 1734065 || Fits Many Models; Please see below for more details. || Please verify the original Simplicity part number in your owner's manual or on the appropriate parts diagram of your model for correct location and fitment of this item.
Genuine Simplicity PTO V-Belt (72.3") || Simplicity Part # 1734065SM || Replaces: 1734065 || Fits Many Models; Please see below for more details. || Please verify the original Simplicity part number in your owner's manual or on the appropriate parts diagram of your model for correct location and fitment of this item.
Compatible equipment models: 1695266:
Information:
Introduction
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.Problem
The 364-4015 Level Sender As for the water tank may give erroneous readings.Solution
Use the following procedure to reset and test the level sender assembly.The level sender assembly must be reset prior to being tested for resistance.
Cycle the float of the level sender assembly to reset any reed switches that may have changed state.
Start with the float at the top of the sender.
Slide the float downward, all the way to the bottom of the sender.
Slide the float upward, all the way to the top of the sender.
Measure the resistance of the level sender assembly, with the float all the way at the top of the sender.Note: The measured resistance with float at the top should equal 30 Ohms 2.3 Ohms.
Return the float to the bottom of the sender.
Measure the resistance of the level sender assembly, with the float all the way at the bottom of the sender.Note: The measured resistance with float at the bottom should equal 240 Ohms 4.8 Ohms.
Slide the float throughout the range from top to bottom of the sender and measure the resistance of the level sender assembly.Note: The measured resistance should rise and fall evenly based on the position of the float.
If the level sender assembly meets all specifications, reinstall the sender.If the level sender assembly does not meet all specifications, replace the sender.
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.Problem
The 364-4015 Level Sender As for the water tank may give erroneous readings.Solution
Use the following procedure to reset and test the level sender assembly.The level sender assembly must be reset prior to being tested for resistance.
Cycle the float of the level sender assembly to reset any reed switches that may have changed state.
Start with the float at the top of the sender.
Slide the float downward, all the way to the bottom of the sender.
Slide the float upward, all the way to the top of the sender.
Measure the resistance of the level sender assembly, with the float all the way at the top of the sender.Note: The measured resistance with float at the top should equal 30 Ohms 2.3 Ohms.
Return the float to the bottom of the sender.
Measure the resistance of the level sender assembly, with the float all the way at the bottom of the sender.Note: The measured resistance with float at the bottom should equal 240 Ohms 4.8 Ohms.
Slide the float throughout the range from top to bottom of the sender and measure the resistance of the level sender assembly.Note: The measured resistance should rise and fall evenly based on the position of the float.
If the level sender assembly meets all specifications, reinstall the sender.If the level sender assembly does not meet all specifications, replace the sender.