1337086 GEAR AS-IDLER Caterpillar parts
140H, 143H, 14H, 160H, 163H, 16H, 3176C, 3196, 345B, 345B II, 345B II MH, 345B L, 365B, 365B II, 365B L, 480, 572R II, 65E, 725, 730, 75D, 75E, 814F, 815F, 816F, 85D, 85E, 95E, 966G II, 972G II, C-10,...
Rating:
Alternative (cross code) number:
CA1337086
133-7086
1337086
CA1337086
133-7086
1337086
Weight: 8 pounds 3 kg.
ARTICULATED TRUCK, WHEELED EXCAVATOR,
Compatible equipment models: 1337086:
Information:
SR4 GeneratorsSR4 generators can be divided into two categories, large frame and small frame. Large frame SR4 generators are used with 3412, 3508, 3512, 3516, D379, D398 and D399 Engines. Illustration 1 shows a typical large frame SR4 generator. Illustration 2 shows a typical small frame SR4 generator.
Illustration 1. Large frame SR4 generator.
Illustration 2. Small frame SR4 generator. Earlier AVR's
Several types of AVR's are used on large frame SR4 generators. Originally, all large frame SR4 generators used either the large self excited AVR, shown in Illustration 3, or the large permanent magnet excited AVR, shown in Illustration 4. Detailed service information for these ARV's is available in SR4 Generator Service Manual, Form SENR2180-01.
Illustration 3. Large self-excited AVR used on large frame SR4 generators
Illustration 4. Large permanent magnet excited AVR used on large frame SR4 generators.The large AVR's are designed to cutoff excitation if an abnormally high excitation current continues for 10 seconds. This causes the generator to stop generating voltage. A problem with earlier self-excited AVR's is that the AVR would reset itself when the voltage fell to zero. This would cause the generator to start generating voltage again until high excitation current would stop the generation again ten seconds later. This cycling would continue until the fault or overload condition was corrected. The large permanent magnet excited AVR did not have this problem. An improved large self-excited AVR was developed to prevent the voltage cycling during a fault or overload.
Improved Large Self-Excited AVR
The improved large self-excited AVR has a new M3 circuit board and K1 circuit breaker. When an overload or fault causes high excitation current for ten seconds, the K1 circuit breaker is tripped and the generator stops generating. The K1 circuit breaker must be manually reset before the generator can be brought back onto the line. Detailed service information for this AVR is available SR4 Generator Service Manual, Form SENR2180-01.
New voltage sensing transformers, T1 and T2, are also used in the improved large self exciting AVR. The new transformers are more reliable because of improved transformer construction methods.
Illustration 5. Improved large self-excited AVR. Small Self-Excited AVR
The small self-excited AVR is now used on all 580 frame and 680 frame self-excited SR4 generators. See Illustration 5. It has single phase half wave regulation. Detailed service information for this AVR is available in SR4 Generator Service Manual, Form SENR7968-03.
Illustration 6. Small self-excited AVR used on 580 and 680 frame size large frame SR4 generators. Remote Mounted Voltage Level Adjustment Rheostat
The large SR4 regulators require a 1000 ohm remote mounted voltage level adjustment rheostat. If a lower resistance value rheostats is used, the generator voltage will be too high. For example, if a 500 ohm rheostat is used, a typical 480 volt generator will regulate at 485 volts minimum.
The small SR4 regulators require a 500 ohm remote mounted voltage level adjustment rheostat.
Illustration 1. Large frame SR4 generator.
Illustration 2. Small frame SR4 generator. Earlier AVR's
Several types of AVR's are used on large frame SR4 generators. Originally, all large frame SR4 generators used either the large self excited AVR, shown in Illustration 3, or the large permanent magnet excited AVR, shown in Illustration 4. Detailed service information for these ARV's is available in SR4 Generator Service Manual, Form SENR2180-01.
Illustration 3. Large self-excited AVR used on large frame SR4 generators
Illustration 4. Large permanent magnet excited AVR used on large frame SR4 generators.The large AVR's are designed to cutoff excitation if an abnormally high excitation current continues for 10 seconds. This causes the generator to stop generating voltage. A problem with earlier self-excited AVR's is that the AVR would reset itself when the voltage fell to zero. This would cause the generator to start generating voltage again until high excitation current would stop the generation again ten seconds later. This cycling would continue until the fault or overload condition was corrected. The large permanent magnet excited AVR did not have this problem. An improved large self-excited AVR was developed to prevent the voltage cycling during a fault or overload.
Improved Large Self-Excited AVR
The improved large self-excited AVR has a new M3 circuit board and K1 circuit breaker. When an overload or fault causes high excitation current for ten seconds, the K1 circuit breaker is tripped and the generator stops generating. The K1 circuit breaker must be manually reset before the generator can be brought back onto the line. Detailed service information for this AVR is available SR4 Generator Service Manual, Form SENR2180-01.
New voltage sensing transformers, T1 and T2, are also used in the improved large self exciting AVR. The new transformers are more reliable because of improved transformer construction methods.
Illustration 5. Improved large self-excited AVR. Small Self-Excited AVR
The small self-excited AVR is now used on all 580 frame and 680 frame self-excited SR4 generators. See Illustration 5. It has single phase half wave regulation. Detailed service information for this AVR is available in SR4 Generator Service Manual, Form SENR7968-03.
Illustration 6. Small self-excited AVR used on 580 and 680 frame size large frame SR4 generators. Remote Mounted Voltage Level Adjustment Rheostat
The large SR4 regulators require a 1000 ohm remote mounted voltage level adjustment rheostat. If a lower resistance value rheostats is used, the generator voltage will be too high. For example, if a 500 ohm rheostat is used, a typical 480 volt generator will regulate at 485 volts minimum.
The small SR4 regulators require a 500 ohm remote mounted voltage level adjustment rheostat.
Cat SIS web machinery list:
Parts gear Caterpillar catalog:
7G3453
GEAR-PLANETARY
14G, 14H, 14H NA, 16G, 16H, 16H NA
14G, 14H, 14H NA, 16G, 16H, 16H NA
3P7041
GEAR-RING
14G, 14H, 14H NA, 16G, 16H, 16H NA
14G, 14H, 14H NA, 16G, 16H, 16H NA
7G3456
GEAR-PLANETARY
14G, 14H, 14H NA, 16G, 16H, 16H NA
14G, 14H, 14H NA, 16G, 16H, 16H NA
8X5303
GEAR-WORM
14G, 14H, 14H NA, 14M
14G, 14H, 14H NA, 14M
8D1858
GEAR-RING
16G, 16H, 16H NA
16G, 16H, 16H NA
8D1669
GEAR-SUN
16G, 16H, 16H NA
16G, 16H, 16H NA
8D1671
GEAR-PLANETARY
16G, 16H, 16H NA
16G, 16H, 16H NA
8X4028
GEAR-WORM
16G, 16H, 16H NA, 16M, 24H, 24M
16G, 16H, 16H NA, 16M, 24H, 24M
8E1913
GEAR AS
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H
9N4161
GEAR AS-OIL PUMP
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
9N4162
GEAR AS-OIL PUMP
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
5I4469
GEAR
330, 330 FM L, 330 L, 330B, 330B L, 345B, 345B L, W330B
330, 330 FM L, 330 L, 330B, 330B L, 345B, 345B L, W330B
1556642
GEAR-CRANKSHAFT
345B, 480, 75D, 85D, C-12, D7R II
345B, 480, 75D, 85D, C-12, D7R II
1302701
GEAR SET-REAR AXLE
426C, 436C
426C, 436C
1382861
GEAR-PINION
65C, 65E, 75D, 75E, 85D
65C, 65E, 75D, 75E, 85D
1591230
GEAR
65C, 65E, 75D, 75E, 85D, 85E, 95E
65C, 65E, 75D, 75E, 85D, 85E, 95E
1311094
GEAR
65C, 65E, 75D, 75E, 85D, 85E, 95E
65C, 65E, 75D, 75E, 85D, 85E, 95E
1311095
GEAR
65C, 75D, 85D
65C, 75D, 85D
1630448
GEAR-RING
35, 45, 55
35, 45, 55
1591234
GEAR-PLANETARY
35, 45, 55
35, 45, 55
1630447
GEAR-RING
35, 45, 55
35, 45, 55
2116758
GEAR
416C, 416D, 420D, 424B, 424B HD, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D
416C, 416D, 420D, 424B, 424B HD, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D
1352826
GEAR
75E, 85D, 85E, 95E
75E, 85D, 85E, 95E
1159424
GEAR-PUMP DRIVE
140H, 143H, 14H, 160H, 163H, 16H, 3176C, 3196, 345B, 345B II, 345B II MH, 345B L, 365B, 365B II, 365B L, 480, 572R II, 65E, 725, 730, 75D, 75E, 814F, 815F, 816F, 85D, 85E, 95E, 966G II, 972G II, C-10,...
140H, 143H, 14H, 160H, 163H, 16H, 3176C, 3196, 345B, 345B II, 345B II MH, 345B L, 365B, 365B II, 365B L, 480, 572R II, 65E, 725, 730, 75D, 75E, 814F, 815F, 816F, 85D, 85E, 95E, 966G II, 972G II, C-10,...