Information:
Illustration 1 g01998973
Schematic of the implement pilot oil pressure sensor
Sales model 854K/992K
This diagnostic code is associated with the Implement Oil Supply Pressure Sensor. This diagnostic code is recorded when the ECM records a signal from the pressure sensor that has an abnormal frequency, abnormal pulse width, or an abnormal period. The sensor produces a PWM signal. The sensor signal wire (C461-OR(Orange)) connects to contact J1-45 of the ECM.The possible causes of this diagnostic code are listed:
The sensor has failed.
The ECM has failed. This is unlikely.Note: The test step “CHECK THE SENSOR” can create numerous related diagnostic codes. The related diagnostic codes will be shown as being not active, after all of the harnesses have been reconnected. Clear all related diagnostic codes after this procedure is completed.Test Step 1. CHECK THE SENSOR.
Turn the disconnect switch and the key start switch to the ON position.
Ensure that the diagnostic code is active.
Observe the status of the diagnostic code. Then, disconnect the sensor from the machine harness. Expected Result:The diagnostic code remains active. When the sensor is unplugged the diagnostic changes to an FMI 03.Results:
OK - The diagnostic code is no longer active. The machine harness and the ECM are operating properly. Proceed to test step 2.
NOT OK - The diagnostic code remains active. The sensor has not failed. The machine harness may have failed or the ECM may have failed. Proceed to Test Step 2.Test Step 2. CHECK THE SIGNAL CIRCUIT FOR A SHORT TO GROUND.
The sensor remains disconnected from the machine harness.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the J1 machine harness connector from the ECM.
At the J1 machine harness connector, measure the resistance from contact J1-45 (wire C461-OR(Orange)) to ground. Expected Result:The resistance is greater than 5000 ohms.Results:
OK - The resistance is greater than 5000 ohms.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. Prior to replacing an ECM, always contact your dealership for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the ECM requires replacement, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOP
NOT OK - The resistance is less than 5000 ohms.Repair: The machine harness has failed. There is a short in the machine harness between the signal circuit and ground. Repair the machine harness or replace the machine harness.STOP
Caterpillar parts catalog:
Parts hose Caterpillar catalog:
3934155
HOSE AS
Caterpillar
Caterpillar
3934154
HOSE AS
Caterpillar
Caterpillar
3934153
HOSE AS
Caterpillar
Caterpillar
3934152
HOSE AS
Caterpillar
Caterpillar
3922435
HOSE AS
Caterpillar
Caterpillar
3821706
HOSE AS
Caterpillar
Caterpillar
3962726
HOSE AS
Caterpillar
Caterpillar
3962725
HOSE AS
Caterpillar
Caterpillar
3953447
HOSE AS
Caterpillar
Caterpillar
3953445
HOSE AS
Caterpillar
Caterpillar
3950745
HOSE AS
Caterpillar
Caterpillar
3948747
HOSE
Caterpillar
Caterpillar