6K3041 LEVER Caterpillar parts
814, 815, 920, 930, 950, 966C
Rating:
Alternative (cross code) number:
CA6K3041
6K-3041
6K3041
CA6K3041
6K-3041
6K3041
Weight: 0.60 pounds 0 kg.
Information:
ARM OFFSET DIMENSION
26.924
mm
AXIS CENTERLINE TO CENTERLINE DIMENSION
114.3
mm
AXIS OFFSET DIMENSION
0
mm
FULCRUM HOLE DIAMETER
19.05
mm
LINKAGE HOLE DIAMETER
10.312
mm
SOIL COMPACTOR, WHEEL LOADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$93.99
05 Jul 2022
1.0[0.45] Pounds
US: RAParts Inc.
6K3041 New Lever for Several Fits Caterpillar Fits CAT Models
Reliable Aftermarket Parts Our Name Says It All One New Aftermarket Replacement Lever Fits Caterpillar Models. Replaces Part Number: Him30-0050, 6K3 || Stock Varies By Warehouse - Please Reference The Estimated Delivery Time For Our Most Accurate Shipp || We Provide Oem Numbers As A Reference For Customers When Ordering. Please Verify Fit By Cross-Refere || We Offer Free Shipping Store-Wide On Any Products Other Than Glass, Decals, Spray Paints, and Seats. || Please Note That Some Listings Use Stock Images As A Reference For Customers.
Reliable Aftermarket Parts Our Name Says It All One New Aftermarket Replacement Lever Fits Caterpillar Models. Replaces Part Number: Him30-0050, 6K3 || Stock Varies By Warehouse - Please Reference The Estimated Delivery Time For Our Most Accurate Shipp || We Provide Oem Numbers As A Reference For Customers When Ordering. Please Verify Fit By Cross-Refere || We Offer Free Shipping Store-Wide On Any Products Other Than Glass, Decals, Spray Paints, and Seats. || Please Note That Some Listings Use Stock Images As A Reference For Customers.
Compatible equipment models: 6K3041:
Information:
Remote Voltage Control
Partial View Of Regulator
(1) Potentiometer. (2) Jumper. (3) Regulator.Generator output voltage level can be controlled from a remote location. This is done by connecting potentiometer (1) between terminals 6 and 7 on voltage regulator (3). Remove jumper (2) between terminals 4 and 7 for remote voltage level control.For acceptable voltage control, the remote mounted potentiometer must be 10k ohms 5% with three turns and a dielectric strength of 1000 VAC minimum.The terminals of the remote mounted potentiometer are fragile. The wiring connected to remote mounted potentiometer (1) should not have a diameter larger than 18 gauge. Larger diameter wire is not recommended. The wire should be 600 volt class with a 90°C (194°F) insulation. Either jumper (2) or remote potentiometer (1) is required for regulator operation.Manual Voltage Control
Manual Voltage Control Schematic With Power Transformer Manual Voltage Control Schematic With Power Transformer and Sensing
Manual Voltage Control Panel
(1) Switch (OFF, AUTO and MAN positions). (2) Voltage control rheostat. (3) Fuse.The manual voltage control can be used to control generator voltage when there is a failure in the generator regulator assembly. It will manually control the current flow to exciter stator L1.The manual voltage control panel has switch (1) and voltage control rheostat (2) for the manual operating mode.Switch (1) is used to make the selection between AUTO, MAN and OFF. In the "AUTO" position, the VR3 regulator controls the generator voltage. In the "OFF" position, the voltage will go to zero. In the "MAN" position, generator voltage is controlled by voltage control rheostat (2). The Manual Voltage Control Panel must not be installed in a location that is subject to engine vibrations or directly to outside weather. When the manual voltage control is operating in the "Manual" mode, it is not necessary for the VR3 regulator to be connected to the generator. However, the manual control must remain connected to generator sensing lines No. 20 and No. 24.Voltage Droop Transformer And Adjustment Rheostat For Parallel Operation
Generator And Regulator Schematic
(1) Voltage droop transformer. (2) Voltage droop rheostat. (3) Lead. (4) Main stator.Operation of generators in parallel requires voltage droop as reactive load is increased. Droop transformer (1) and adjustment rheostat (2) are required to provide the voltage droop function. The transformer senses load current in lead (3) of main stator (4). Droop rheostat (2) provides adjustment of droop voltage. Rheostat (2) is located directly next to the regulator on the regulator mounting bracket.Transformer (1) is standard on some generators and is an attachment on others. Rheostat (2) is an attachment on all units. Droop transformer (1) is a special ratio transformer. Droop transformer (1) must be installed on generator phase lead T2 with transformer polarity connections as shown.
Partial View Of Regulator
(1) Potentiometer. (2) Jumper. (3) Regulator.Generator output voltage level can be controlled from a remote location. This is done by connecting potentiometer (1) between terminals 6 and 7 on voltage regulator (3). Remove jumper (2) between terminals 4 and 7 for remote voltage level control.For acceptable voltage control, the remote mounted potentiometer must be 10k ohms 5% with three turns and a dielectric strength of 1000 VAC minimum.The terminals of the remote mounted potentiometer are fragile. The wiring connected to remote mounted potentiometer (1) should not have a diameter larger than 18 gauge. Larger diameter wire is not recommended. The wire should be 600 volt class with a 90°C (194°F) insulation. Either jumper (2) or remote potentiometer (1) is required for regulator operation.Manual Voltage Control
Manual Voltage Control Schematic With Power Transformer Manual Voltage Control Schematic With Power Transformer and Sensing
Manual Voltage Control Panel
(1) Switch (OFF, AUTO and MAN positions). (2) Voltage control rheostat. (3) Fuse.The manual voltage control can be used to control generator voltage when there is a failure in the generator regulator assembly. It will manually control the current flow to exciter stator L1.The manual voltage control panel has switch (1) and voltage control rheostat (2) for the manual operating mode.Switch (1) is used to make the selection between AUTO, MAN and OFF. In the "AUTO" position, the VR3 regulator controls the generator voltage. In the "OFF" position, the voltage will go to zero. In the "MAN" position, generator voltage is controlled by voltage control rheostat (2). The Manual Voltage Control Panel must not be installed in a location that is subject to engine vibrations or directly to outside weather. When the manual voltage control is operating in the "Manual" mode, it is not necessary for the VR3 regulator to be connected to the generator. However, the manual control must remain connected to generator sensing lines No. 20 and No. 24.Voltage Droop Transformer And Adjustment Rheostat For Parallel Operation
Generator And Regulator Schematic
(1) Voltage droop transformer. (2) Voltage droop rheostat. (3) Lead. (4) Main stator.Operation of generators in parallel requires voltage droop as reactive load is increased. Droop transformer (1) and adjustment rheostat (2) are required to provide the voltage droop function. The transformer senses load current in lead (3) of main stator (4). Droop rheostat (2) provides adjustment of droop voltage. Rheostat (2) is located directly next to the regulator on the regulator mounting bracket.Transformer (1) is standard on some generators and is an attachment on others. Rheostat (2) is an attachment on all units. Droop transformer (1) is a special ratio transformer. Droop transformer (1) must be installed on generator phase lead T2 with transformer polarity connections as shown.
Cat SIS web machinery list:
Parts lever Caterpillar catalog:
7K3756
LEVER (Front Left Hand)
825B, 930, 930R
825B, 930, 930R
6K7382
LEVER
518, 518C, 528, 528B, 530B, 814, 920, 930, 930R, 950, 966C, 966R, 980B, 992, FB518
518, 518C, 528, 528B, 530B, 814, 920, 930, 930R, 950, 966C, 966R, 980B, 992, FB518
4K1431
LEVER
966C
966C
4K1432
LEVER
966C
966C
6K7382
LEVER
518, 518C, 528, 528B, 530B, 814, 920, 930, 930R, 950, 966C, 966R, 980B, 992, FB518
518, 518C, 528, 528B, 530B, 814, 920, 930, 930R, 950, 966C, 966R, 980B, 992, FB518
4D1545
LEVER
651, 657
651, 657
4D7269
LEVER
657, 666
657, 666
6M4456
LEVER ASSEM.
650B
650B
8F7024
LEVER
650B
650B
8S9014
LEVER
651
651
7K8434
LEVER (Lift)
920, 930, 930R
920, 930, 930R
8F4330
LEVER
666
666
3D6896
LEVER
666
666
4D2239
LEVER
666
666