1560235 LOCK Caterpillar parts
120H, 120H ES, 120H NA, 135H, 135H NA, 30/30, 3114, 3116, 3126, 3126B, 3126E, 320B, 322B L, 322B LN, 322C, 322C FM, 325, 325B L, 325C, 35, 446B, 446D, 45, 525B, 533, 535B, 539, 543, 55, 550, 570, 574,...
Rating:
Alternative (cross code) number:
CA1560235
156-0235
1560235
CA1560235
156-0235
1560235
Weight: 0.04 pounds 0 kg.
ASPHALT PAVER, WHEELED EXCAVATOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
156-0235 Lock Fits Caterpillar
Reliable Aftermarket Parts OEM Numbers Are Provided for Reference Only. Please Verify Fit Prior To Ordering. || Please Note: Some Listings Use Stock Images for Reference and May Differ from the Actual Product. || This Aftermarket Part Is Made to Meet or Exceed Manufacturer (OEM) Specifications. || All OEM part numbers and logos are to be used for identification purposes only.
Reliable Aftermarket Parts OEM Numbers Are Provided for Reference Only. Please Verify Fit Prior To Ordering. || Please Note: Some Listings Use Stock Images for Reference and May Differ from the Actual Product. || This Aftermarket Part Is Made to Meet or Exceed Manufacturer (OEM) Specifications. || All OEM part numbers and logos are to be used for identification purposes only.
RAParts 1560235 156-0235-Lock Fits Caterpillar (Fits CAT)962G IT38F 938G 960F 938F IT12F 950G
Reliable Aftermarket Parts Replaces Part Number: 1560235,156-0235 || OEM Numbers Are Provided for Reference Only. Please Verify Fit Prior To Ordering. || Please Note: Some Listings Use Stock Images for Reference and May Differ from the Actual Product. || This Aftermarket Part Is Made to Meet or Exceed Manufacturer (OEM) Specifications. || All OEM part numbers and logos are to be used for identification purposes only.
Reliable Aftermarket Parts Replaces Part Number: 1560235,156-0235 || OEM Numbers Are Provided for Reference Only. Please Verify Fit Prior To Ordering. || Please Note: Some Listings Use Stock Images for Reference and May Differ from the Actual Product. || This Aftermarket Part Is Made to Meet or Exceed Manufacturer (OEM) Specifications. || All OEM part numbers and logos are to be used for identification purposes only.
Stevens Lake Parts One New Lock Various Applications & Models Replaces 156-0235 1560235 1560235-A
Stevens Lake Parts One New Lock || This Is An Aftermarket Part Made To Replace Its OEM Counterpart. || Interchangeable With 156-0235 1560235 1560235-A || OEM Numbers Are Provided for Reference Only. Please Verify Fit Prior To Ordering. || Please Note: Some Listings Use Stock Images for Reference and May Differ from the Actual Product.
Stevens Lake Parts One New Lock || This Is An Aftermarket Part Made To Replace Its OEM Counterpart. || Interchangeable With 156-0235 1560235 1560235-A || OEM Numbers Are Provided for Reference Only. Please Verify Fit Prior To Ordering. || Please Note: Some Listings Use Stock Images for Reference and May Differ from the Actual Product.
Compatible equipment models: 1560235:
Information:
Lead Numbering
Wye Configuration Diagram
6 Lead
Illustration 1 g00611486
6 Lead Wye Configuration
Terminals T4, T5 and T6 become neutral connections when the terminals are tied together.
Grounding the Frame
In any generator set installation, the frame of the generator must be positively connected to an earth ground. This connection should be the first connection that is made during installation. This connection should be the last connection that is removed. The ground connection must be flexible in order to avoid breakage during operation.Ground connection cable or straps should have at least the current carrying capacity of the largest line lead to the connected load. Joints in cables or straps must be clean, free of electrical resistance, and protected from possible oxidation. Bolted ground connection joints eventually oxidize. The joints are frequent sources of radio frequency interference (RFI). Bolted connections should be silver soldered for the best performance.Neutral Connections
Generators with grounded configurations usually have a neutral that is grounded when the generator is installed. Ground the neutral in order to prevent equipment damage and personal injury. If the neutral wire is grounded and one of the phase leads becomes grounded, the excessive current will open a load circuit breaker in order to isolate the fault. If the circuit breaker does not open, then the excessive current will reduce the generator voltage to zero. The result depends on the characteristics of the generator, the type of fault, and the trip rating of the circuit breaker. An undervoltage device may be required in order to provide an adequate short circuit protection.Some installations do not require the neutral wire to be grounded. Ungrounded neutral leads are acceptable if measures have been taken in order to prevent grounds to the phase leads. An example of such measures are ground fault protective circuits. All of the distribution circuits must be treated as a system in order to ensure ground fault protection. The operator should contact a certified, registered consultant if a new distribution system is being developed. The owner should also contact a certified, registered consultant if an existing system should be modified for the ground fault protection. Neutral resistors and reactors may be added to the system in order to provide protection during faults. Neutral resistors and reactors may also be added in order to limit neutral currents. Single Units
In a three-phase, four-wire system, the neutral wire should be grounded according to local wiring codes.If definite measures have been taken in order to prevent grounds to the load leads, an ungrounded neutral can be used. Be sure to check your local wiring codes.Multiple Units
Operating more than one generator in parallel may result in current circulating through the neutral connections when all of the neutral leads have been grounded. In order to eliminate the possibility of circulating currents, ground the neutral of only one generator. If multiple generators are alternated on one line, a switch should be installed in the neutral ground circuit of each generator. In this case, all of the neutral ground circuits except one can be opened. Be
Wye Configuration Diagram
6 Lead
Illustration 1 g00611486
6 Lead Wye Configuration
Terminals T4, T5 and T6 become neutral connections when the terminals are tied together.
Grounding the Frame
In any generator set installation, the frame of the generator must be positively connected to an earth ground. This connection should be the first connection that is made during installation. This connection should be the last connection that is removed. The ground connection must be flexible in order to avoid breakage during operation.Ground connection cable or straps should have at least the current carrying capacity of the largest line lead to the connected load. Joints in cables or straps must be clean, free of electrical resistance, and protected from possible oxidation. Bolted ground connection joints eventually oxidize. The joints are frequent sources of radio frequency interference (RFI). Bolted connections should be silver soldered for the best performance.Neutral Connections
Generators with grounded configurations usually have a neutral that is grounded when the generator is installed. Ground the neutral in order to prevent equipment damage and personal injury. If the neutral wire is grounded and one of the phase leads becomes grounded, the excessive current will open a load circuit breaker in order to isolate the fault. If the circuit breaker does not open, then the excessive current will reduce the generator voltage to zero. The result depends on the characteristics of the generator, the type of fault, and the trip rating of the circuit breaker. An undervoltage device may be required in order to provide an adequate short circuit protection.Some installations do not require the neutral wire to be grounded. Ungrounded neutral leads are acceptable if measures have been taken in order to prevent grounds to the phase leads. An example of such measures are ground fault protective circuits. All of the distribution circuits must be treated as a system in order to ensure ground fault protection. The operator should contact a certified, registered consultant if a new distribution system is being developed. The owner should also contact a certified, registered consultant if an existing system should be modified for the ground fault protection. Neutral resistors and reactors may be added to the system in order to provide protection during faults. Neutral resistors and reactors may also be added in order to limit neutral currents. Single Units
In a three-phase, four-wire system, the neutral wire should be grounded according to local wiring codes.If definite measures have been taken in order to prevent grounds to the load leads, an ungrounded neutral can be used. Be sure to check your local wiring codes.Multiple Units
Operating more than one generator in parallel may result in current circulating through the neutral connections when all of the neutral leads have been grounded. In order to eliminate the possibility of circulating currents, ground the neutral of only one generator. If multiple generators are alternated on one line, a switch should be installed in the neutral ground circuit of each generator. In this case, all of the neutral ground circuits except one can be opened. Be
Cat SIS web machinery list:
Parts lock Caterpillar catalog:
1279810
LOCK
3126, 3126B, 3126E, 322C, 322C FM, 325C, C7, M325C MH
3126, 3126B, 3126E, 322C, 322C FM, 325C, C7, M325C MH
1279811
LOCK
3126, 3126B, 3126E, 322C, 322C FM, 325C, C7, M325C MH
3126, 3126B, 3126E, 322C, 322C FM, 325C, C7, M325C MH
2680457
LOCK AS
305.5, 307C, 312C, 312C L, 315C, 315D L, 317B LN, 318B, 318C, 319C, 319D L, 320B, 320C, 320C L, 320D, 321C, 322B L, 322B LN, 322C, 323D L, 324D L, 325B L, 325C, 325D, 325D L, 325D MH, 330B L, 330C, 33...
305.5, 307C, 312C, 312C L, 315C, 315D L, 317B LN, 318B, 318C, 319C, 319D L, 320B, 320C, 320C L, 320D, 321C, 322B L, 322B LN, 322C, 323D L, 324D L, 325B L, 325C, 325D, 325D L, 325D MH, 330B L, 330C, 33...
5M5000
LOCK
215, 215B, 225, 227, 229, 235, 235C, 561C, 571G, 572G, 931B, 931C, 931C II, 933, 933C, 939, 939C, 941, 943, 951B, 953, 953B, 953C, 953D, 955H, 955K, 955L, 963, 963B, 963C, 963D, 973, 973C, 977K, 977L,...
215, 215B, 225, 227, 229, 235, 235C, 561C, 571G, 572G, 931B, 931C, 931C II, 933, 933C, 939, 939C, 941, 943, 951B, 953, 953B, 953C, 953D, 955H, 955K, 955L, 963, 963B, 963C, 963D, 973, 973C, 977K, 977L,...
8J6239
LOCK
231D, 235, 235D, 245, 943, 953, 953B, 963, 963B, 973
231D, 235, 235D, 245, 943, 953, 953B, 963, 963B, 973
8J6236
LOCK
231D, 235, 235D, 245, 943, 953, 953B, 963, 963B, 973
231D, 235, 235D, 245, 943, 953, 953B, 963, 963B, 973
4E3897
LOCK
2470C, 2570C, 2670C, 2864C, 515, 518C, 525, 525B, 525C, 533, 535B, 535C, 543, 545, 545C, 553C, 563C, 573C, 586C, 814F, 814F II, 815F, 815F II, 816F, 816F II, 918F, 924F, 928F, 928G, 928H, 928HZ, 930G,...
2470C, 2570C, 2670C, 2864C, 515, 518C, 525, 525B, 525C, 533, 535B, 535C, 543, 545, 545C, 553C, 563C, 573C, 586C, 814F, 814F II, 815F, 815F II, 816F, 816F II, 918F, 924F, 928F, 928G, 928H, 928HZ, 930G,...
2K0537
LOCK-BEARING
518, 528, 528B, 530B, 611, 613, 613B, 613C, 613C II, 613G, 615, 615C, 814, 814B, 815, 815B, 816B, 910, 916, 920, 926, 930, 930R, 936, 950, 950B, 950B/950E, 966C, 966D, 966F, 966G, CS-643, D250B, D250E...
518, 528, 528B, 530B, 611, 613, 613B, 613C, 613C II, 613G, 615, 615C, 814, 814B, 815, 815B, 816B, 910, 916, 920, 926, 930, 930R, 936, 950, 950B, 950B/950E, 966C, 966D, 966F, 966G, CS-643, D250B, D250E...
6G7187
LOCK
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 14...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 14...
8D9784
LOCK
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
9D9797
LOCK
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
7B5037
LOCK-BOLT
120B, 120G, 120H, 120K, 120K 2, 12F, 12G, 12H, 130G, 135H, 140B, 140G, 140H, 140K, 14E, 160G, 160H, 160K
120B, 120G, 120H, 120K, 120K 2, 12F, 12G, 12H, 130G, 135H, 140B, 140G, 140H, 140K, 14E, 160G, 160H, 160K
1W2715
LOCK-RETAINER
120H, 120H ES, 120H NA, 120K, 120K 2, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 135H NA, 140G, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 205B, 214B, 224B, ...
120H, 120H ES, 120H NA, 120K, 120K 2, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 135H NA, 140G, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 205B, 214B, 224B, ...
5Q4018
LOCK GP
330B L, 330C L
330B L, 330C L
5B2407
LOCK
3114, 3116, 3126, 3126B, 3176B, 3176C, 3196, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3516, 3516B, 3516C, C-1...
3114, 3116, 3126, 3126B, 3176B, 3176C, 3196, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3516, 3516B, 3516C, C-1...
4B4773
LOCK
3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3456, C-15, C-16, C-9, C11, C13, C15, C18, C9, C9.3, CX31-C15I, CX31-C18I, CX31-C9I, CX35-C18I, CX35-P800, D342, D342C, ...
3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3456, C-15, C-16, C-9, C11, C13, C15, C18, C9, C9.3, CX31-C15I, CX31-C18I, CX31-C9I, CX35-C18I, CX35-P800, D342, D342C, ...
3N8123
LOCK PIN
3114, 3116, 3126, 3126B, 3176B, 3176C, 3196, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3516, 3516B, 3516C, C-1...
3114, 3116, 3126, 3126B, 3176B, 3176C, 3196, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3516, 3516B, 3516C, C-1...
8S1491
LOCK
120G, 12G, 12H, 12H ES, 12H NA, 130G, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 1673C, 215, 215B, 235, 235B, 3204, 330, 330 L, 3304, 3304B, 3306, 3306B, 3...
120G, 12G, 12H, 12H ES, 12H NA, 130G, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 1673C, 215, 215B, 235, 235B, 3204, 330, 330 L, 3304, 3304B, 3306, 3306B, 3...
8S4645
LOCK
1140, 1673B, 1673C, 1676, 3176, 3208, 3306, 3306C, 3406, 3406B, 3406C, 3408, 3408C, 3408E, 3412, 623F, 772, 773, 777, 980B, D6C
1140, 1673B, 1673C, 1676, 3176, 3208, 3306, 3306C, 3406, 3406B, 3406C, 3408, 3408C, 3408E, 3412, 623F, 772, 773, 777, 980B, D6C
7N0243
LOCK-ROD BOLT
1673C, 16G, 3176, 3208, 3304, 3306, 3306B, 3306C, 3406, 3406B, 3406C, 3408, 3408C, 3408E, 3412E, 3512, 3512B, 3512C, 3516C, 5130, 5230, 613C, 627B, 627E, 631D, 631E, 631G, 633D, 633E II, 637D, 637E, 6...
1673C, 16G, 3176, 3208, 3304, 3306, 3306B, 3306C, 3406, 3406B, 3406C, 3408, 3408C, 3408E, 3412E, 3512, 3512B, 3512C, 3516C, 5130, 5230, 613C, 627B, 627E, 631D, 631E, 631G, 633D, 633E II, 637D, 637E, 6...