6G4701 NUT-BEARING Caterpillar parts
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
Rating:
Alternative (cross code) number:
CA6G4701
6G-4701
6G4701
CA6G4701
6G-4701
6G4701
Weight: 1 pounds 0 kg.
MOTOR GRADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$42.50
09 Jun 2022
US: Florida-Parts-Z
6G4701 - NUT-Bearing 7D8355 for Caterpillar (CAT)
FIRST PRICE PARTS
FIRST PRICE PARTS
Compatible equipment models: 6G4701:
Information:
System Operation Description:Use this procedure to troubleshoot the following codes:Also use this procedure if a fault is suspected with the ARD ignition system.
Table 1
Diagnostic Trouble Codes for the Ignition System for the Aftertreatment Regeneration Device (ARD)    
J1939 Code     Description     Notes    
3484-5     Aftertreatment #1 Ignition : Current Below Normal     The Electronic Control Module (ECM) detects the following conditions:
The current flow through the primary ignition circuit is below the threshold while the ECM is trying to spark the plug.
The ECM has been powered for at least 2 seconds.
If equipped, the warning lamp will come on. The ECM will log the diagnostic code.
If a regeneration is in progress, the ARD completes the regeneration.    
3484-6     Aftertreatment #1 Ignition : Current Above Normal     The ECM detects the following conditions:
There is excessive current flow through the secondary ignition circuit or there is excessive current flow through the primary ignition circuit.
The ECM has been powered for at least 2 seconds.
If equipped, the warning lamp will come on. The ECM will log the diagnostic code.    
4265-5     Aftertreatment #1 Transformer Secondary Output : Current Below Normal     The ECM detects the following conditions:
The ARD has attempted to ignite three times. All of the attempts were unsuccessful. There is a fault with the current flow through the secondary circuit. The primary circuit is OK.
The ECM has been powered for at least 2 seconds.
If equipped, the warning lamp will come on. The ECM will log the diagnostic code.    
4265-6     Aftertreatment #1 Transformer Secondary Output : Current Above Normal     The ECM detects the following conditions:
The ARD has attempted to ignite three times. All of the attempts were unsuccessful. The ECM has detected a fault with the current flow through the secondary circuit. The primary circuit is OK.
The ECM has been powered for at least 2 seconds.
If equipped, the warning lamp will come on. The ECM will log the diagnostic code.    
Illustration 1 g02452934
Schematic diagram for the ARD ignition circuit
Illustration 2 g01970576
Typical view of the pin locations on the P2 connector for ARD ignition (12) ARD ignition coil supply (13) ARD ignition coil return
Illustration 3 g02166895
Typical view of the pin locations on the 31-pin connector and the 40-pin connector for the ARD ignition circuit
Illustration 4 g02452961
Typical view of Clean Emissions Module (CEM) (1) Ignition coil (2) 40-pin connector (3) ARD combustion head
Illustration 5 g01970517
Identification of terminals on the ignition coil
Illustration 6 g02931777
ARD combustion head (4) ARD combustion head (5) Spark plug (6) Ignition wire (7) Ground electrode (8) Spark plug electrode (9) Ground wire (10) Ground pointSystem OperationThe ARD ignition system has two circuits. The primary circuit is between the ECM and the ignition coil. The secondary circuit is between the ignition coil and the ARD combustion head. The current flow through the primary circuit indicates the condition of the primary circuit and of the secondary circuit. The ECM monitors the current flow through the primary circuit. In this way, the ECM is able to detect faults in the primary circuit and
Table 1
Diagnostic Trouble Codes for the Ignition System for the Aftertreatment Regeneration Device (ARD)    
J1939 Code     Description     Notes    
3484-5     Aftertreatment #1 Ignition : Current Below Normal     The Electronic Control Module (ECM) detects the following conditions:
The current flow through the primary ignition circuit is below the threshold while the ECM is trying to spark the plug.
The ECM has been powered for at least 2 seconds.
If equipped, the warning lamp will come on. The ECM will log the diagnostic code.
If a regeneration is in progress, the ARD completes the regeneration.    
3484-6     Aftertreatment #1 Ignition : Current Above Normal     The ECM detects the following conditions:
There is excessive current flow through the secondary ignition circuit or there is excessive current flow through the primary ignition circuit.
The ECM has been powered for at least 2 seconds.
If equipped, the warning lamp will come on. The ECM will log the diagnostic code.    
4265-5     Aftertreatment #1 Transformer Secondary Output : Current Below Normal     The ECM detects the following conditions:
The ARD has attempted to ignite three times. All of the attempts were unsuccessful. There is a fault with the current flow through the secondary circuit. The primary circuit is OK.
The ECM has been powered for at least 2 seconds.
If equipped, the warning lamp will come on. The ECM will log the diagnostic code.    
4265-6     Aftertreatment #1 Transformer Secondary Output : Current Above Normal     The ECM detects the following conditions:
The ARD has attempted to ignite three times. All of the attempts were unsuccessful. The ECM has detected a fault with the current flow through the secondary circuit. The primary circuit is OK.
The ECM has been powered for at least 2 seconds.
If equipped, the warning lamp will come on. The ECM will log the diagnostic code.    
Illustration 1 g02452934
Schematic diagram for the ARD ignition circuit
Illustration 2 g01970576
Typical view of the pin locations on the P2 connector for ARD ignition (12) ARD ignition coil supply (13) ARD ignition coil return
Illustration 3 g02166895
Typical view of the pin locations on the 31-pin connector and the 40-pin connector for the ARD ignition circuit
Illustration 4 g02452961
Typical view of Clean Emissions Module (CEM) (1) Ignition coil (2) 40-pin connector (3) ARD combustion head
Illustration 5 g01970517
Identification of terminals on the ignition coil
Illustration 6 g02931777
ARD combustion head (4) ARD combustion head (5) Spark plug (6) Ignition wire (7) Ground electrode (8) Spark plug electrode (9) Ground wire (10) Ground pointSystem OperationThe ARD ignition system has two circuits. The primary circuit is between the ECM and the ignition coil. The secondary circuit is between the ignition coil and the ARD combustion head. The current flow through the primary circuit indicates the condition of the primary circuit and of the secondary circuit. The ECM monitors the current flow through the primary circuit. In this way, the ECM is able to detect faults in the primary circuit and
Cat SIS web machinery list:
Parts nut Caterpillar catalog:
1A1415
NUT
120B, 120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12E, 12F, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140, 140B, 140G, 140H, 140H ES, 140H NA, 140...
120B, 120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12E, 12F, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140, 140B, 140G, 140H, 140H ES, 140H NA, 140...
9X2521
NUT-FULL
120M, 120M 2, 12M, 12M 2, 12M 3, 12M 3 AWD, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 160M, 160M 2, 160M 3, 160M 3 AWD, 163H NA, D3B, D3C III, D4C, D4C III, D5C III
120M, 120M 2, 12M, 12M 2, 12M 3, 12M 3 AWD, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 160M, 160M 2, 160M 3, 160M 3 AWD, 163H NA, D3B, D3C III, D4C, D4C III, D5C III
3B5753
NUT-FULL
120B, 12E, 12F, 130G, 140B, 14E, 25, 528, 572G, 572R, 572R II, 594, 594H, 621, 623, 630B, 631C, 633C, 637D, 651, 657, 768B, 768C, 769, 772, 773, 824B, 834, 988
120B, 12E, 12F, 130G, 140B, 14E, 25, 528, 572G, 572R, 572R II, 594, 594H, 621, 623, 630B, 631C, 633C, 637D, 651, 657, 768B, 768C, 769, 772, 773, 824B, 834, 988
1B4439
NUT
120, 120B, 120G, 12E, 12G, 130G, 140, 140B, 14E, 14G, 4S, 561B, 561C, 561D, 571G, 5S, 621, 621B, 621R, 623, 627B, 631C, 633C, 637, 641, 641B, 651, 657, 657B, 6A, 6S, 7A, 8A, 9A, D4D, D4E, D5, D6C, D7F...
120, 120B, 120G, 12E, 12G, 130G, 140, 140B, 14E, 14G, 4S, 561B, 561C, 561D, 571G, 5S, 621, 621B, 621R, 623, 627B, 631C, 633C, 637, 641, 641B, 651, 657, 657B, 6A, 6S, 7A, 8A, 9A, D4D, D4E, D5, D6C, D7F...
1B4443
NUT
120, 120B, 12E, 12F, 12G, 140, 140B, 140G, 14E, 16, 16G, 571G, 572G, 583H, 583K, 594, 594H, 621, 621B, 623B, 627, 627B, 633, 824, 824B, 825C, 825G, 825G II, 825H, 988, AP-1000B, AP-600D, AP-800C, AP-8...
120, 120B, 12E, 12F, 12G, 140, 140B, 140G, 14E, 16, 16G, 571G, 572G, 583H, 583K, 594, 594H, 621, 621B, 623B, 627, 627B, 633, 824, 824B, 825C, 825G, 825G II, 825H, 988, AP-1000B, AP-600D, AP-800C, AP-8...
2B2673
NUT
120, 120B, 120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12E, 12F, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140, 140B, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14E, 160G, 160H, 160H ...
120, 120B, 120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12E, 12F, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140, 140B, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14E, 160G, 160H, 160H ...
9F4364
NUT-SLOTTED
120G, 12G, 130G, 140G, 651E, 657E, AP-800, PR190
120G, 12G, 130G, 140G, 651E, 657E, AP-800, PR190
2F8057
NUT-SLOTTED
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 143H,...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 143H,...
6S3065
NUT
120G, 12G, 130G, 140G, 14G, 160G, 16G, 24H, CB-334D, CB-335D
120G, 12G, 130G, 140G, 14G, 160G, 16G, 24H, CB-334D, CB-335D
2G6396
NUT
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 135H, 135H NA
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 135H, 135H NA
8D3540
NUT
12G, 12H, 12H ES, 12H NA, 12K, 130G, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
12G, 12H, 12H ES, 12H NA, 12K, 130G, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
7D8833
NUT
120G, 12F, 12G, 130G, 140G, 14E, 14G, 16, 16G
120G, 12F, 12G, 130G, 140G, 14E, 14G, 16, 16G
6G4702
NUT
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 135H, 135H NA
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 135H, 135H NA
8X2092
NUT
120G, 12G, 130G, 140G, 160G, 16G
120G, 12G, 130G, 140G, 160G, 16G
0093161
NUT
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G
5B9097
NUT
D7G
D7G
IT5911
NUT
D7R
D7R
9J0084
NUT
12G, 130G, 140G
12G, 130G, 140G
8D3540
NUT
12G, 12H, 12H ES, 12H NA, 12K, 130G, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
12G, 12H, 12H ES, 12H NA, 12K, 130G, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
7D9801
NUT
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G
9D0608
NUT
120G, 12G, 130G, 140G, 14G, 160G, 16G
120G, 12G, 130G, 140G, 14G, 160G, 16G
6D9679
NUT-SPEED
120, 120G, 12F, 12G, 130G, 140B, 140G, 14E, 14G, 16, 160G, 16G
120, 120G, 12F, 12G, 130G, 140B, 140G, 14E, 14G, 16, 160G, 16G
2G6396
NUT
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 135H, 135H NA
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 135H, 135H NA