1057936 PANEL AR-SWITCHGEAR Caterpillar parts
3508, 3512, 3516
Rating:
Alternative (cross code) number:
CA1057936
105-7936
1057936
CA1057936
105-7936
1057936
GEN SET ENGINE,
Information:
Illustration 1 g00878014
Illustration 2 g01013109
P1 ECM connectorTest Step 1. Inspect Electrical Connectors and Wiring
Turn the keyswitch to the OFF/RESET position.
Thoroughly inspect the J1/P1 ECM connector, the J61/P61 machine connector, the J405/P405 decelerator position sensor connector and all other connectors in the circuit. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.Expected Result:All connectors, pins, and sockets are completely inserted and coupled. The harness and wiring are free of corrosion, of abrasion, and of pinch points. All connections and grounds are tight and free of corrosion.Results:
OK - The connectors and the wiring appear to be OK. Proceed to Test Step 2.
Not OK - There is a problem with the connectors and/or the wiring.Repair: Repair the circuit.Verify that the repair eliminates the problem.STOPTest Step 2. Check for Shorts in the Harness from the ECM to the Decelerator Position Sensor
Disconnect the J1/P1 ECM connector and the J405/P405 decelerator position sensor connector.
Measure the resistance between P1:4 (+8 VDC) and engine ground.
Measure the resistance between P1:4 (+8 VDC) and P1:5 (Return).
Leave the J1/P1 ECM connector and the decelerator position sensor disconnected.Expected Result:The resistance is greater than 20,000 Ohms for each measurement.Results:
OK - The resistance is greater than 20,000 Ohms for each measurement. Proceed to Test Step 3.
Not OK - There is a short between the ECM and the sensor.Repair: Repair the circuit.STOPTest Step 3. Check for Open Circuits in the Harness Between the ECM and the Decelerator Position SensorNote: The J1/P1 ECM connector and the decelerator position sensor should still be disconnected.
Install a jumper wire between P1:4 (+8 VDC) and P1:5 (Return).
Measure the resistance between terminal A (+8 VDC) and terminal B (Return) of the P405 decelerator position sensor connector on the wiring harness.Expected Result:The resistance is less than 10 Ohms.Results:
OK - The resistance is less than 10 Ohms.Repair: Remove the jumper wire and reconnect the J1/P1 ECM connector. Leave the decelerator position sensor disconnected. Proceed to Test Step 4.
Not OK - There is an open circuit in the wiring harness between the sensor and the ECM.Repair: Repair the circuit.Verify that the repair eliminates the problem.STOPTest Step 4. Check the Digital Sensor Supply Voltage at the Sensor Connector
Turn the keyswitch to the ON position.
Measure the voltage across terminal A (+8 VDC) and terminal B (Return) of the P405 decelerator position sensor connector on the wiring harness.Expected Result:The digital sensor supply voltage is 8.0 0.5 VDC.Results:
OK - The supply voltage is reaching the sensor. Proceed to Test Step 5.
Not OK - The supply voltage is not reaching the sensor. Proceed to Test Step 7.Test Step 5. Check the Digital Sensor for an Internal Short
Install a 7X-6370 Adapter Cable As (3 Pin DT Breakout) at the sensor connector, but do not connect the sensor to the breakout at this time.
Turn the keyswitch to the ON position.
Reconnect the decelerator position sensor while you observe the voltage across terminals A (+8 VDC) and B (Return) at the breakout.Expected Result:The supply voltage is 8.0 0.5 VDC and the voltage does not drop when the sensor is connected.Results:
OK -
Caterpillar SIS machinery equipment:
Caterpillar SIS
3516 Generator Set Engine 25Z00684-02188 »
105-7936
PANEL AR-SWITCHGEAR
3516 Generator Set Engine 4XF00001-UP »
105-7936
PANEL AR-SWITCHGEAR
3516 Generator Set Engine 5SJ00001-UP »
105-7936
PANEL AR-SWITCHGEAR
3508 Generator Set Engine (High Speed) 23Z03489-UP »
105-7936
PANEL AR-SWITCHGEAR
3512 Generator Set Engine 24Z04366-UP »
105-7936
PANEL AR-SWITCHGEAR
3516 Generator Set Engine 25Z02189-UP »
105-7936
PANEL AR-SWITCHGEAR
Parts panel Caterpillar catalog:
3569954
PANEL AS
3508, 3512, 3512B, 3516, 3516B, 3516C
3508, 3512, 3512B, 3516, 3516B, 3516C
3569955
PANEL AS
3508, 3512, 3512B, 3516, 3516B, 3516C
3508, 3512, 3512B, 3516, 3516B, 3516C
2450072
PANEL AS
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C175-16, C27, C32
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C175-16, C27, C32
5N5077
PANEL ASSEM.
3512
3512
5N5074
PANEL ASSEM.
3512
3512
5N9483
PANEL ASSEM.
3512, 3516, D398B, D399
3512, 3516, D398B, D399
5N9490
PANEL ASSEM.
3512, 3516, D398B, D399
3512, 3516, D398B, D399
5N9456
PANEL ASSEM.
3508, 3512, D379B, D398B, SR4
3508, 3512, D379B, D398B, SR4
5N9470
PANEL ASSEM.
3508, 3512, D379B, D398B, SR4
3508, 3512, D379B, D398B, SR4
5N8600
PANEL AS
3512, 3516, D398B, D399, SR4
3512, 3516, D398B, D399, SR4
5N7156
PANEL AS
3512, 3516, D398B, D399, SR4
3512, 3516, D398B, D399, SR4
1085568
PANEL AS
3508, 3512, 3512B, 3516, 3516B, C32
3508, 3512, 3512B, 3516, 3516B, C32
1891939
PANEL GP-INSTRUMENT
990 II
990 II
1690212
PANEL GP-CONTROL
3412C
3412C
2137994
PANEL GP-RELAY
621G, 623G, 627G, 631G, 637G
621G, 623G, 627G, 631G, 637G
8U6336
PANEL GP-INSTRUMENT
206B, 212B
206B, 212B
2668864
PANEL GP-ELECTRICAL
C2.2, C3.3, C4.4
C2.2, C3.3, C4.4
2505599
PANEL GP-TOP
966H, 972H
966H, 972H
1785269
PANEL GP-INSTRUMENT
3176C, 3196, C-10, C-12, SBF214
3176C, 3196, C-10, C-12, SBF214
1690208
PANEL GP-CONTROL
3412C
3412C
2389614
PANEL GP-INSTRUMENT
824H, 825H, 826H
824H, 825H, 826H
3487615
PANEL GP-INSTRUMENT
568 FM LL
568 FM LL