Illustration 1 g00889633
Schematic of the Solenoid Valve (Travel Brake)This diagnostic code is related to the travel brake solenoid.This diagnostic code is recorded when the ECM reads the current of the solenoid as being above normal.The possible causes are listed:
A wire is shorted to ground.
The solenoid has failed.
The ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0377 FMI 06 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:The ECM is not able to control the travel brake. The travel brake is always ON.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness. Expected Result:CID 0377 FMI 06 changes to CID 0377 FMI 05 when the solenoid is disconnected.Results:
YES - CID 0377 FMI 06 changes to CID 0377 FMI 05 when the solenoid is disconnected. The circuit is correct.Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Stop.
NO - CID 0377 FMI 06 remains active. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
The solenoid remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the ECM.
At the machine harness connector, measure the resistance from the signal contact J2-7 (wire J967-GY) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-7 (wire J967-GY) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. Stop.Test Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 0377 FMI 06. Expected Result:The CID 0377 FMI 06 is active. Results:
YES - The CID 0377 FMI 06 is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace". Stop.
NO - The CID 0377 FMI 06 is not active. The diagnostic code does not exist
Parts puller Caterpillar catalog:
1471744
PULLER-BEARING
Caterpillar
Caterpillar
1455242
PULLER KIT
Caterpillar
Caterpillar
1435637
PULLER
Caterpillar
Caterpillar
1428279
PULLER-SLEEVE
Caterpillar
Caterpillar
1402182
PULLER-STUD
Caterpillar
Caterpillar
1400169
PULLER-
Caterpillar
Caterpillar
1944802
PULLER-BEARING
Caterpillar
Caterpillar
1943725
PULLER-BEARING
Caterpillar
Caterpillar
1918306
PULLER-GEAR
Caterpillar
Caterpillar
1735527
PULLER GP-
Caterpillar
Caterpillar
1673834
PULLER GP.
Caterpillar
Caterpillar
1567100
PULLER GP - LD
Caterpillar
Caterpillar