Introduction
ReferenceOperation and Maintenance, SEBU7731, "216B, 226B, 232B, 236B, 242B, 246B, 248B, 252B, 262B, and 268B Skid Steer Loaders"ReferenceOperation and Maintenance, SEBU7732, "247B, 257B, 267B, 277B, and 287B Skid Steer Loaders"The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.Problem
The fuse for the condenser fan motor fails during start-up of the fan motor. This results in the malfunction of the air conditioning system.Solution
Replace the 124-3548 Fuse with a 180-0613 Circuit Breaker As . Use the procedure that follows:
Turn off the air conditioner switch and park the machine. Refer to Operation and Maintenance, "Parking" for instructions on parking your machine.
Inspect the blades and the motors for the condenser fans.
Clean the dirt and any debris from the fan guard, the fan blade, and the motor.
Spin the fan blade. As you spin the fan blades, you will feel detents due to the magnets in the fan.Note: The fan blades should spin freely. If the fan blades are bound or if the blades will not spin freely, replace the motor.
Inside the cab, locate the fuse panel which is below the operator's seat. Remove the cover in order to access the fuses.
Illustration 1 g01457205
The location of the 30 amp fuse for the fans for the air conditioner condenser
Remove the green 30 amp fuse for the fans for the air conditioner condenser. See Illustration 1.Note: This fuse is located in position (22) in the fuse panel.
Install the 180-0613 Circuit Breaker As in position (22) in the fuse panel.Then, replace the cover on the fuse panel.
Turn the engine start switch to the On position.
Turn the air conditioner switch to the ON position and check that the condenser fans are operating.Note: If the circuit breaker trips during three attempts to start the condenser fans, replace the faulty motor. Use caution. The circuit breaker can only cycle a maximum of 10 times before the circuit breaker will fail.
ReferenceOperation and Maintenance, SEBU7731, "216B, 226B, 232B, 236B, 242B, 246B, 248B, 252B, 262B, and 268B Skid Steer Loaders"ReferenceOperation and Maintenance, SEBU7732, "247B, 257B, 267B, 277B, and 287B Skid Steer Loaders"The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.Problem
The fuse for the condenser fan motor fails during start-up of the fan motor. This results in the malfunction of the air conditioning system.Solution
Replace the 124-3548 Fuse with a 180-0613 Circuit Breaker As . Use the procedure that follows:
Turn off the air conditioner switch and park the machine. Refer to Operation and Maintenance, "Parking" for instructions on parking your machine.
Inspect the blades and the motors for the condenser fans.
Clean the dirt and any debris from the fan guard, the fan blade, and the motor.
Spin the fan blade. As you spin the fan blades, you will feel detents due to the magnets in the fan.Note: The fan blades should spin freely. If the fan blades are bound or if the blades will not spin freely, replace the motor.
Inside the cab, locate the fuse panel which is below the operator's seat. Remove the cover in order to access the fuses.
Illustration 1 g01457205
The location of the 30 amp fuse for the fans for the air conditioner condenser
Remove the green 30 amp fuse for the fans for the air conditioner condenser. See Illustration 1.Note: This fuse is located in position (22) in the fuse panel.
Install the 180-0613 Circuit Breaker As in position (22) in the fuse panel.Then, replace the cover on the fuse panel.
Turn the engine start switch to the On position.
Turn the air conditioner switch to the ON position and check that the condenser fans are operating.Note: If the circuit breaker trips during three attempts to start the condenser fans, replace the faulty motor. Use caution. The circuit breaker can only cycle a maximum of 10 times before the circuit breaker will fail.
Parts tube Caterpillar catalog:
5088269
TUBE
Caterpillar
Caterpillar
5088268
TUBE
Caterpillar
Caterpillar
5088267
TUBE
Caterpillar
Caterpillar
5088259
TUBE AS-OIL
Caterpillar
Caterpillar
5088177
TUBE AS
Caterpillar
Caterpillar
5088091
TUBE-RH (TOP)
Caterpillar
Caterpillar
5092954
TUBE AS-
Caterpillar
Caterpillar
5092801
TUBE AS
Caterpillar
Caterpillar
5092015
TUBE AS-AIR
Caterpillar
Caterpillar
5091039
TUBE AS
Caterpillar
Caterpillar
5089063
TUBE AS
Caterpillar
Caterpillar
5089060
TUBE
Caterpillar
Caterpillar