3663828 CONTROL GP-THROTTLE Caterpillar parts
R1300, R1300G
Rating:
Alternative (cross code) number:
CA3663828
366-3828
3663828
CA3663828
366-3828
3663828
Weight: 1 pounds 0 kg.
LOAD HAUL DUMP,
Information:
diagnostics for the ECM can be accessed through one of the following tools: the Operator Monitoring System and Cat® Electronic Technician (Cat ET). To troubleshoot the electronic control system of the machine, additional information is required from the Service Manual of the machine. The following list contains some of the required support materials:
Operation and Maintenance Manual, SEBU8796, "621K Wheel Tractor Scraper"
Electrical Schematic, KENR2689, "621K Wheel-Tractor Scraper Electrical System (Interactive)"
Hydraulic Schematic, UENR2692, "Hydraulic Schematic 621K and 627K (T4F/LRC)"
Troubleshooting/Systems Operation/Test and Adjust, UENR3162, "621K, 623K, and 627K Wheel Tractor-Scraper Monitoring Systems"As a guide, a typical system schematic for the electrical system is included at the end of this manual. For an accurate representation of the machine that is being diagnosed, refer to Electrical System Schematic in the Service Manual.When the troubleshooting procedure instructs you to “REPAIR OR REPLACE THE HARNESS”, use the Electrical System Schematic for the machine that is being serviced to trace the circuit. Perform continuity checks at the harness connectors to locate harness failures. At the connectors of the components, always check the ground circuit. Less than 5 ohms of resistance is required between the ground contacts of the connector and the frame ground. The power circuits of the ECM should have less than 2 ohms of resistance between the contacts of the ground connector and the frame ground. Less than 5 ohms of resistance is required for signal circuits for normal operation. Excessive ground resistance that is greater than 5 ohms can cause incorrect diagnosing of problems.During troubleshooting, inspect all connections before any component is replaced. If these connections are not clean and tight, permanent electrical problems or intermittent electrical problems can result. Check that the wires are pushed into the connectors completely. Make sure that the connections are tight before other tests are made.Failure of an electrical component can cause the failure of other components. Also, failure of an electrical component can be caused by the failure of other components. Always attempt to correct the cause of an electrical system failure before you replace a component.
Operation and Maintenance Manual, SEBU8796, "621K Wheel Tractor Scraper"
Electrical Schematic, KENR2689, "621K Wheel-Tractor Scraper Electrical System (Interactive)"
Hydraulic Schematic, UENR2692, "Hydraulic Schematic 621K and 627K (T4F/LRC)"
Troubleshooting/Systems Operation/Test and Adjust, UENR3162, "621K, 623K, and 627K Wheel Tractor-Scraper Monitoring Systems"As a guide, a typical system schematic for the electrical system is included at the end of this manual. For an accurate representation of the machine that is being diagnosed, refer to Electrical System Schematic in the Service Manual.When the troubleshooting procedure instructs you to “REPAIR OR REPLACE THE HARNESS”, use the Electrical System Schematic for the machine that is being serviced to trace the circuit. Perform continuity checks at the harness connectors to locate harness failures. At the connectors of the components, always check the ground circuit. Less than 5 ohms of resistance is required between the ground contacts of the connector and the frame ground. The power circuits of the ECM should have less than 2 ohms of resistance between the contacts of the ground connector and the frame ground. Less than 5 ohms of resistance is required for signal circuits for normal operation. Excessive ground resistance that is greater than 5 ohms can cause incorrect diagnosing of problems.During troubleshooting, inspect all connections before any component is replaced. If these connections are not clean and tight, permanent electrical problems or intermittent electrical problems can result. Check that the wires are pushed into the connectors completely. Make sure that the connections are tight before other tests are made.Failure of an electrical component can cause the failure of other components. Also, failure of an electrical component can be caused by the failure of other components. Always attempt to correct the cause of an electrical system failure before you replace a component.
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts control Caterpillar catalog:
1729389
CONTROL GP-UNPROGRAMMED
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 24H, 525B, 535B, 545, 561N, 572R...
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 24H, 525B, 535B, 545, 561N, 572R...
3702377
CONTROL AR-RIDE
R1300G
R1300G
1550140
CONTROL GP-BUCKET
R1300, R1300G, R1300G II
R1300, R1300G, R1300G II
3266837
CONTROL GP-GOVERNOR
R1300G
R1300G
2433434
CONTROL GP-STEERING
R1300G, R1300G II
R1300G, R1300G II
3E0461
CONTROL GP-ELECTRONIC
69D, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 784B, 785B, 789B, 793B, 793C, 936F, 963, 963B, 973, 992C, 994, 994D, AD40, AD45, AE40, AE40 II, R1300, R1600, R1700 II, R1700G, R2900
69D, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 784B, 785B, 789B, 793B, 793C, 936F, 963, 963B, 973, 992C, 994, 994D, AD40, AD45, AE40, AE40 II, R1300, R1600, R1700 II, R1700G, R2900
1869790
CONTROL GP-HANDLE
R1300, R1300G, R1600, R1600G, R1600H, R1700G, R2900, R2900G, R3000H
R1300, R1300G, R1600, R1600G, R1600H, R1700G, R2900, R2900G, R3000H
3093092
CONTROL BOX
R1300
R1300
3114716
CONTROL BOX
AD45, AE40 II, R1300
AD45, AE40 II, R1300
2277623
CONTROL GP-HANDLE
345C, 345C L
345C, 345C L
1392822
CONTROL GP-GOVERNOR
3606, 3608, 3612, 3616
3606, 3608, 3612, 3616
2669959
CONTROL & MTG GP-COMMUNICATION
938G II, IT38G II
938G II, IT38G II
4339535
CONTROL AR-QUICK COUPLER
311F LRR
311F LRR
6C9300
CONTROL GP-PILOT OPERATED HYD
320 L, 330 L, 350, 375, 5080
320 L, 330 L, 350, 375, 5080
8W9322
CONTROL GP-AIR STARTING
789, 789B, 789C
789, 789B, 789C
2872053
CONTROL GP-JOYSTICK
924G, 924GZ, 924H, 928HZ, 930G
924G, 924GZ, 924H, 928HZ, 930G