3236189 COUPLING AS- Caterpillar parts
Rating:
Alternative (cross code) number:
CA3236189
323-6189
3236189
CA3236189
323-6189
3236189
Weight: 0.28 pounds 0 kg.
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$62.99
27 Jul 2022
2.0[0.90] Pounds
US: Fix_My_Toys
Polaris Ranger BAR, Qty 1
Polaris For schematic location 8 only || See product description below for vehicle fitment or to verify fitment for your specific vehicle, please contact us, and provide us with your VIN that can be found on your vehicle or your insurance card.
Polaris For schematic location 8 only || See product description below for vehicle fitment or to verify fitment for your specific vehicle, please contact us, and provide us with your VIN that can be found on your vehicle or your insurance card.
Information:
Conveyor and Auger Control
For machines configured with two material height sensors, the right and left conveyor control dials vary the relative speed of the conveyors to the augers. When the control setting is at zero percent, the conveyor dials provide the maximum speed differential between the conveyors and the augers. At zero percent, the conveyor operates at the minimum speed. When the control setting is at 100 percent, the dials provide the minimum speed differential between the conveyors and the augers. At 100 percent, the conveyor operates at the maximum speed.For machines configured with four material height sensors, the right and left conveyor control dials vary the speed of the conveyors. The varied speed is based on the height of material at the back of the conveyors. The height of the material at the back of the conveyors is measured by the conveyor material height sensors. In the four sensor configuration, the conveyors and the augers operate independently.Machine ECM (15) automatically detects whether the machine is equipped with paddle sensors or sonic sensors. When paddle sensors are installed, the respective ECM terminals are floating. When sonic sensors are installed, the terminals are grounded by the sensor. The machine ECM monitors the status of the following terminals:
"J1-33" signals the left conveyor status
"J1-34" signals the right conveyor status
"J1-44" signals the left auger status
"J1-45" signals the right auger statusFor machines configured with zero material height sensors, the augers and conveyors operate in open-loop mode. Auger and conveyor speeds are controlled by the corresponding speed dials.Note: The operator configures the number of sensors used for the material feed system through the operator display. If"Zero" sensors is selected, installed sensors will not be used.Machine ECM (15) compares the input signals from the conveyor material height sensors to the input signals from the conveyor control dials. In this case, the machine ECM determines if the actual amount of material
For machines configured with two material height sensors, the right and left conveyor control dials vary the relative speed of the conveyors to the augers. When the control setting is at zero percent, the conveyor dials provide the maximum speed differential between the conveyors and the augers. At zero percent, the conveyor operates at the minimum speed. When the control setting is at 100 percent, the dials provide the minimum speed differential between the conveyors and the augers. At 100 percent, the conveyor operates at the maximum speed.For machines configured with four material height sensors, the right and left conveyor control dials vary the speed of the conveyors. The varied speed is based on the height of material at the back of the conveyors. The height of the material at the back of the conveyors is measured by the conveyor material height sensors. In the four sensor configuration, the conveyors and the augers operate independently.Machine ECM (15) automatically detects whether the machine is equipped with paddle sensors or sonic sensors. When paddle sensors are installed, the respective ECM terminals are floating. When sonic sensors are installed, the terminals are grounded by the sensor. The machine ECM monitors the status of the following terminals:
"J1-33" signals the left conveyor status
"J1-34" signals the right conveyor status
"J1-44" signals the left auger status
"J1-45" signals the right auger statusFor machines configured with zero material height sensors, the augers and conveyors operate in open-loop mode. Auger and conveyor speeds are controlled by the corresponding speed dials.Note: The operator configures the number of sensors used for the material feed system through the operator display. If"Zero" sensors is selected, installed sensors will not be used.Machine ECM (15) compares the input signals from the conveyor material height sensors to the input signals from the conveyor control dials. In this case, the machine ECM determines if the actual amount of material
Parts coupling Caterpillar catalog:
3236188
COUPLING AS-
Caterpillar
Caterpillar
3236187
COUPLING AS-
Caterpillar
Caterpillar
3236186
COUPLING AS-
Caterpillar
Caterpillar
3236185
COUPLING AS-
Caterpillar
Caterpillar
3236184
COUPLING AS-
Caterpillar
Caterpillar
3236183
COUPLING AS-
Caterpillar
Caterpillar
3236195
COUPLING AS-
Caterpillar
Caterpillar
3236194
COUPLING AS-
Caterpillar
Caterpillar
3236193
COUPLING AS-
Caterpillar
Caterpillar
3236192
COUPLING AS-
Caterpillar
Caterpillar
3236191
COUPLING AS-
Caterpillar
Caterpillar
3236190
COUPLING AS-
Caterpillar
Caterpillar